Setting of helium plasma device (J-Plasma) inflap elevationTo the Editor:

We read with interest the article,“Use of low tempera-ture helium plasma (J-Plasma) for dissection and hemo-stasis during carotid endarterectomy,”1 recently published in theJournal of Vascular Surgery Cases and Innovative Techniques. In our opinion, this article repre-sents such an innovative surgical technique that deserves to be shared.

In our department, the Plastic Surgery Division of the University Hospital of Modena, we have experienced various instruments, from traditional devices for dissec-tion and coaguladissec-tion2,3 to the most recent helium plasma (J-Plasma) device we implemented for the eleva-tion of the freeflap in microsurgery.4

As with the Filis et al experience,1we have found advan-tages of this device over traditional devices, such as the possibility of performing dissection and hemostasis simultaneously, as well as the absence of muscle dissec-tion and the absence of fat necrosis associated to nonfor-mation of serum and/or burn tissues during dissection. Furthermore, we found a significant decreased risk of accidental tissue trauma.4

We believe that the Filis et al article is critical to encourage dissection of vessels through such a safety de-vice. Moreover, Filis et al state that a generator power setting at 20 W cutting mode and 30 W coagulation modes, but did not specify the helium gasflow rate. In our experience, the setting for this instrument is different: for a freeflap fibula, we use to set up gas flow rate at 4 L and radiofrequency power at 30% in coagulation and cutting, whereas in the radialflap for forearm set up is within 3 L gasflow and 20% of power.4

These settings were used for all stages of the microsur-gical procedure, including dissection of the peduncle (both artery and vein). The system allows to implement-ing additional modes: Turbo Cut, able to facilitate precise dissection in high impedance filmed tissue, and a Cool

Coag mode, applicable for wider hemostasis. All modes can be applied by using the instrument's integrated blade either extended or retracted.

However, in our experience, to facilitate anastomosis, we separated the artery from the vein of the peduncle with traditional microforceps and scissors. These vessels have a smaller caliber than the common carotid artery. In our opinion, the Filis et al experience can be very encouraging for the future use of helium plasma in dissecting vessels in plastic surgery, for example, when performing a perforator flap. In accord with Filis et al, we believe that the settings can be reevaluated in the future with increasing experience. Specific settings based on vessel sizes should be studied. We hope that our experience will be useful to increase knowledge on setting up helium plasma.

Marta Starnoni, MD Massimo Pinelli, MD Giorgio De Santis, MD

Department of Plastic and Reconstructive Surgery University Hospital of Modena

Modena, Italy

REFERENCES

1. Filis K, Galyfos G, Sigala F, Zografos G. Utilization of

low-temperature helium plasma (J-Plasma) for dissection and hemostasis during carotid endarterectomy. J Vasc Surg Cases

Innov Tech 2020;6:152-5.

2. Baccarani A, Starnoni M, De Santis G. Ultrasonic cutting and

coagulating device in implant-based breast reconstruction.

Plast Reconstr Surg Glob Open 2018;6:e2020.

3. Starnoni M, Pinelli M, De Santis G. Fibula freeflap elevation

without tourniquet: are harmonic scalpel shears useful? Plast

Reconstr Surg Glob Open 2019;7:e2409.

4. Pinelli M, Starnoni M, De Santis G. The use of cold atmospheric

plasma device in flap elevation. Plast Reconstr Surg Glob

Open 2019;7:e2102.

https://doi.org/10.1016/j.jvscit.2020.07.008

Riferimenti

Documenti correlati

If we choose the first option, for coherence’s sake we mustn’t attribute a gender to newborns with a sharp sex either: in fact, if the reason for this missing attribution is

Based on the consistent background and knowledge that the UMinho has in ‘Building Information Modelling’, a practical roadmap towards the full BIM digitalization of

We study the scattering factor between gluons with rapidity u and (small) fermions with ra- pidity x f (v) in perturbative regime of the strong coupling limit, i.e... (4.69)

Table S2 Number of rice reads per pool deconvoluted to one, two, or three BACs; the percentage column reports the fraction of the total number of reads that were deconvoluted to

The year when the injuries happened, the cause, the location, and the degree of the burns, the size and the duration of treatment are the indicators examined in

Essa si propone piuttosto come un nucleo originario di valutazione della Scuola di Firenze e della sua identità alla luce delle ricerche che negli ultimi dieci

There is a wide variety of signal types, whose design and treatment is the subject of extensive research: (a) a generic GNSS signal generation, transmission, and

Materials and methods - The first phase of the study involved a comparison of the histological appearance of the cut skin in three cases of mastectomy in which different methods