• Non ci sono risultati.

View of Influence of groundwater temperature variation on thermal plume modelling in geothermal open loop systems

N/A
N/A
Protected

Academic year: 2021

Condividi "View of Influence of groundwater temperature variation on thermal plume modelling in geothermal open loop systems"

Copied!
2
0
0

Testo completo

(1)

3rd National Meeting on Hydrogeology Cagliari, 14-16 June 2017

IAH Italian Chapter

University of Cagliari – Department of Chemical and Geological Sciences

INFLUENCE OF GROUNDWATER TEMPERATURE VARIATION ON

THERMAL PLUME MODELLING IN GEOTHERMAL OPEN LOOP

SYSTEMS

Stefano LO RUSSO 1, Glenda TADDIA 1, Elena CERINO ABDIN 1

1 Department of Environment, Land and Infrastructure Engineering (DIATI), Politecnico di Torino, C.so

Duca degli Abruzzi 24-10129 Torino, Italy, stefano.lorusso@polito.it

The Groundwater Heat Pump system is a technology that withdraws water from a well or surface water, passes it through a heat exchanger and discharges the water into an injection well or nearby river, developing a thermal plume of colder/warmer re-injected water, known as the Thermal Affected Zone (TAZ). Plumes are considered a potential anthropogenic geothermal resource or pollution, in fact they might pose a risk to groundwater use downgradient. It is then important to know early in the project whether the aquifer is suitable for the system to be implemented and whether the TAZ will interfere with existing wells, subsurface infrastructure or land use.

Physical processes affecting heat transport within an aquifer include advection (or convection), mechanical dispersion and diffusion (Diao et al., 2004). Plume propagation occurs primarily through advection (Lo Russo and Taddia, 2010), and tends to “degrade” following conductive heat transport, and convection within moving water (Hecht-Mendez et al., 2010). The results of a sensitive analysis realized by Lo Russo et al. (2012) indicates that the main hydrodynamic parameters that influence the heat transport are hydraulic conductivity and gradient.

As the hydraulic conductivity varies according to the temperature due to the variation of the water dynamic viscosity, in the present study we evaluate the influence on heat transport of the groundwater temperature variation induced by an open-loop system reinjection system. To investigate this topic a sensitive analysis has been realized using FEFLOW® 6.2 package developed by Diersch (2010).

FEFLOW gives the possibility to include or disregard the dynamic viscosity variation related to the groundwater temperature and therefore we simulated these two scenarios. For each of them nine different cases have been considered using the combination between three different conductivity classes and three different injection temperatures values. For each case (K-Treinj) the isotherms obtained in both scenarios have been compared geometrically.

The two scenarios analysed highlighted that the variation of the dynamic viscosity with the groundwater temperature affects the extension of the TAZ in the cases of higher values of aquifer hydraulic conductivity and/or in the situations of warmer injected water and therefore in these modelling contexts it should be taken into account to correctly assess the subsurface thermal perturbation.

References

Diao N, Li Q, Fang Z (2004) Heat transfer in ground heat exchangers with groundwater advection. Int. J. Thermal Sci., 43: 1203-1211.

Diersch H.J.G.(2010) FEFLOW 6 – User’s Manual. WASY GmbH, Berlin.

(2)

3rd National Meeting on Hydrogeology Cagliari, 14-16 June 2017

IAH Italian Chapter

University of Cagliari – Department of Chemical and Geological Sciences

transport simulation of closed geothermal systems. Ground Water 48(5), 741-756.

Lo Russo S, Taddia G (2010) Advective heat transport in an unconfined aquifer induced by the field injection of an open-loop groundwater heat pump. American Journal of Environmental Sciences 6(3), 253-259 DOI: 10.3844/ajessp.2010.253.259.

Lo Russo S, Taddia G, Verda V (2012) Development of the thermally affected zone (TAZ) around a ground water heat pump (GWHP) system: a sensitivity analysis. Geothermics 43:66– 74. doi:10.1016/j.geothermics.2012.02.001.

Riferimenti

Documenti correlati

Examining the simulated water budget of the Tuzla Lake for 50% reduction in groundwater pumping rates with respect to reference conditions (Scenario 2), we can see that in that

Seppure limitata alla parte dei filtri e in parte del dreno, la precipitazione determina anch’essa un intasamento rispetto alla possibilità di iniettare acque nel sottosuolo,

Despite of the small power consumption in the stand-by mode (in the presented case, according to the manufacturer’s data approx. 25 W, without taking into account the

The thermal efficiency of air heat pumps applied for the production of domestic how water is determined by a number of factors such as: course of tapping cycle, ambient

Data of the two heat pumps working during one heating season was analysed to determine the influence of heat sink temperature on the Seasonal Performance Factor.. Results of

9 presents the thermal energy supplied by HP units and its driving energy (electricity) for analyzed water temperature drop, years and water flows. It is evident, that the

One of the most widely used and economical is the incorporation of adsorption and absorption method, which biogas purification work using a water spray particles to bind water

Discounted Payback Period for the investment involving DWHR unit(s) operating along with gas water heaters and p = 100 min is between almost 2 and more than 4 years. If