Smoke Sensor Module

General Description:

A smoke sensor is a device that senses smoke, typically as an indicator of fire. Commercial and residential security devices issue a signal to a fire alarm control panel as part of a fire alarm system, while household detectors, known as smoke alarms, generally issue a local audible or visual alarm from the detector itself.

The Analog Smoke/LPG/CO Gas Sensor (MQ2) module utilizes an MQ-2 as the sensitive component and has a protection resistor and an adjustable resistor on board. The MQ-2 gas sensor is sensitive to LPG, i-butane, propane, methane, alcohol, Hydrogen and smoke. It could be used in gas leakage detecting equipments in family and industry. The resistance of the sensitive component changes as the concentration of the target gas changes.

(2)

Specifications:

 Dimension: 32mm x 22mm x 30mm Specification:  Operating voltage: 5v

 Detection Zone: 300 - 10000ppmm  Characteristic Gas: 1000ppmm

 Sensitivity: R in air/ R in typical gas > 5  Response Time: <10s

 Recovery time: <30s  Heating Resistance: 31ohm  Heating Current: <181mA  Heating Power: <900mW  Measuring Voltage: <24  Ambient Temperature: -20C - 55C  Humidity: <95%  Oxygen Content: 21% Pin Configuration: 1. VCC 2. D0 pin 3. A0 pin 4. Ground

(3)

Schematic Diagram:

How to test:

1. Connect your Arduino microcontroller to the computer.

2. Connect the VCC pin of your module to the to the 5V pin of your Arduino. 3. Connect the GND pin of your module to the GND pin of your Arduino. 4. Connect the Output pin of your module to the A0 pin of you Arduino.

5. Enter this program to your Arduino Integrated Development Environment (IDE):

void setup() { Serial.begin(9600); } void loop() {

if (analogRead(A0) < 100) Serial.println("No Smoke"); else Serial.println("Smoke Detected!");

delay(100); }

6. Click the Upload Button

(4)

Testing Results:

When there is no smoke exposure:

When exposed to a burning paper:

Riferimenti

Documenti correlati

I valori di portata di corrente sono riferiti a: tutti i conduttori attivi (eccetto il conduttore giallo/verde) - Profondità di posa 0,8 m per i cavi interrati. *Available

Le Détecteur de Monoxyde de Carbone NCO01 est conforme à l’ensemble des caractéristiques essentielles de la norme harmonisée EN 50291-1 : 2018. Le texte complet de la déclaration

Adolescent exposure to on-screen smoking is substantially higher in countries where film classification regimes assign youth ratings to many films that are rated R in the USA..

property vector MDS fitting analyses, 238, 250 serial rape CAP model, 231 sexual murder CAP model,

products (e.g., smoke alarms, sprinklers), environmental interventions (residential design and household equipment factors that reduce the risk of fire injury), and

Prevede un impegno formale per gli Studenti a non fumare per un periodo di 6 mesi (dal 1 novembre al 30 aprile) durante il quale i Docenti di riferimento possono

In occasione del 31 Maggio 2019 “Giornata Mondiale senza Tabacco” le classi coinvolte potranno promuovere attività di sensibilizzazione indirizzate a ridurre la

In occasione del 31 Maggio 2022 “Giornata Mondiale senza Tabacco” le classi coinvolte potranno promuovere attività di sensibilizzazione indirizzate a ridurre la diffusione