Measuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination

N/A
N/A
Protected

Academic year: 2021

Condividi "Measuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination"

Copied!
9
0
0

Testo completo

(1)

these limits can be reliably overcome even in laboratories without a local atomic clock by replacing the GPS with a 642-km-long optical fiber link to a remote primary cae-sium frequency standard. Through this configuration we stably address the 1S

0—3P0

clock transition in an ultracold gas of173Yb, with a precision that exceeds the possibil-ities of a GPS-based measurement, dismissing the need for a local clock infrastructure to perform high-precision tasks beyond GPS limit. We also report an improvement of two orders of magnitude in the accuracy on the transition frequency reported in literature.

Frequency and time dissemination is of fundamental im-portance for the modern world, as it rules a wealth of applications, ranging from coordination of global trans-port to synchronization of high-precision tasks in both scientific and industrial sectors. A timely exploitation of the continuous advances in the realization of new fre-quency standards is inherently tied to the uncertainty with which the standard is delivered from metrological in-stitutes to the end-users. Presently, the most widespread dissemination method is the GPS, allowing for traceability to the second in the International System (SI) of units with a typical fractional frequency uncertainty of 10−13on a day average [1]. This remarkable result can be obtained with a very simple equipment, consisting only of a receiver without any feedback from the user to the reference clock infrastructure. However, GPS dissemination severely de-grades the accuracy of current frequency standards and even more that of the optical atomic clocks [2], which have already shown fractional accuracy capabilities of 10−18in few hours of measurement [3–5]. This is the main reason why the development and characterization of long-haul optical fiber links (OFLs), rather than microwave satellite links, recently featured a substantial thrust [6–10]. Indeed, in the last years OFLs have shown undoubted effectiveness in comparing remote atomic clocks beyond the ultimate limit of GPS-based comparisons, attaining precision levels not limited by the frequency transfer method [11–15], and are also envisioned as key elements for the development of a new kind of high-accuracy relativistic geodesy [15, 16]. Besides optical clock comparisons, short-range OFLs have recently been exploited in order to increase the spectral performances of a local laser and to allow for precision

molecular spectroscopy [17].

However, there is still no evidence about their successful utilization to disseminate a primary absolute frequency reference to remote laboratories lacking a local atomic clock, in such a way as to push both precision and ac-curacy of local measurements and applications beyond the GPS limit. A demonstration of such a capability would represent a breakthrough, as it would allow remote, non-metrological end-users to realize tasks requiring an ultra-high degree of accuracy, which are unattainable with GPS-disciplined standards. Focusing on possible scientific outcomes of this new approach, a paradigmatic example comes from experiments involving alkaline-earth-like (AEL) atoms. Very recently, these systems proved to lie amongst the most promising and rich platforms for the development of new quantum technologies. Coherent control on their electronic and nuclear degrees of free-dom allows for the realization of quantum simulators of a wealth of fundamental effects which are hardly attain-able (if not unfeasible) in their original physical context, with the investigation of orbital quantum magnetism [18], SU(N ) fermionic systems [19–21], synthetic gauge fields [22], as well as the implementation of reliable quantum information schemes [23, 24]. Much of the interest sought in this class of atoms resides in the possibility to handle their orbital degree of freedom through the forbidden transition1S

0—3P0 [25–29], that is also exploited for the

realization of optical lattice clocks with neutral atoms [2]. However, most of the aforementioned experimental schemes rely on cyclical addressing of the clock transition (featuring linewidths of few Hz) for hours or even days, creating the need for manipulation lasers with narrow linewidth and exceptional long-term stability. Whilst the

(2)

FIG. 1. Sketch of the experimental system. Left panel: generation of the optical signal, frequency-referenced to the Cs primary standard at the metrological institute INRIM (Turin), for long-haul optical frequency dissemination. Right panel: end-user spectroscopy system at LENS (Florence), along with signal regeneration and frequency bridging with a local frequency comb. Note that other users can exploit the reference after regeneration due to a “point-to-star” dissemination configuration.

first requirement is easily met through high-finesse cavity stabilization, long-term stability can only be achieved through referencing to atomic clocks, whose availability is primarily restricted to metrological institutes.

Here, we demonstrate that the excellent long-term sta-bility of an ultrastable near-infrared laser, stabilized to an atomic clock, can be transferred from a metrological institute to a remote, non-metrological research labo-ratory through a 642-km-long optical fiber link. This allows for a long-term, SI-traceable spectroscopy of the

1S

0—3P0 transition in a quantum degenerate AEL gas of 173Yb. The absolute measurement of the173Yb1S

0—3P0

transition frequency is 518 294 576 845 268 (10) Hz on typ-ical timescales of few hours, and improves the previously known value by two orders of magnitude [30]. Noticeably, this degree of accuracy exceeds by 20 times the pefor-mances attainable with a GPS-based frequency transfer on the same timescale [1]. Our results pave the way for a new generation of optically-referenced high-precision setups beyond the GPS limit showing no need for a local optical clock infrastructure.

Optical frequency link: setup and performances The complete system (Cs fountain clock + optical fre-quency reference + optical link + remote spectroscopic setup) is shown in Fig. 1. An optical frequency reference is generated in a national metrological institute (INRIM, Turin, Italy) by frequency-stabilizing a 1542-nm fiber laser to a Ultra Low Expansion glass (ULE) cavity [31]. On the long-term, the laser is phase-locked to a hydrogen maser (HM) referenced to a Cs fountain primary frequency stan-dard with 2 × 10−16relative frequency accuracy [32]. This ensures excellent long-term stability and SI-traceability (see Methods). The optical reference is disseminated from INRIM to LENS via a phase-stabilized 642-km-long fiber link characterized at the 5 × 10−19level of uncertainty [8].

The occurrence of occasional phase-slips is continuously monitored to keep undesired frequency offsets < 10−16 on

the delivered frequency (see Methods). At LENS, the in-coming optical reference is regenerated and fiber-delivered to the end-user lab (see Methods). Multiple amplified output slots are available, realizing a “point-to-star” con-figuration, where other end-users could also connect to the regeneration stage, either with free-running or stabilized links upon specific metrological needs. In the end-user lab, a quantum-dot laser at 1156 nm is frequency sta-bilized to a high-finesse ULE cavity [33, 34]. Although this cavity is enclosed in a thermally-insulating box, the stabilized laser shows stochastic frequency fluctuations mainly arising from the non-perfect thermal stabilization of the ULE cavity, in addition to a linear (aging) drift of about 5 kHz/day [34]. This instability is compensated by frequency-locking the 1156-nm laser to the disseminated radiation at 1542 nm, using an optical frequency comb as a bridge between the two spectral regions. The complete metrological chain provides the end-user with a 1156-nm laser frequency traceable to the SI second, realized by the Cs fountain; the 1156-nm laser keeps its own high spectral purity on the short term, while the long-term stability is granted by the fiber-disseminated signal on measurement times of tens of seconds. The 1156-nm laser radiation is then frequency-doubled to 578 nm and used for spectroscopy of the 1S

0–3P0 clock transition of an

ultracold sample of173Yb.

Fig. 2a shows the frequency noise spectrum of the employed optical sources referred to the 1156 nm spectral region. The blue line represents the frequency noise of the 1542-nm reference laser, disciplined to the HM, when compared to an independent, cavity-stabilized laser at INRIM. The red curve represents the frequency noise of the beatnote between the 1542-nm laser and the 1156-nm laser through the frequency-comb bridge. A significant noise increase can be noticed at Fourier frequencies higher

(3)

FIG. 2. Performances of the optical frequency link stabilization. a. Red line: frequency noise of the beatnote between the local laser at 1156 nm and the reference laser at 1542 nm; blue line: frequency noise of the HM-disciplined 1542-nm laser as measured at INRIM; black line: expected contribution of the optical link. All the spectra are referred to the 1156-nm spectral region. b. Blue line (circles): fractional frequency instability (Allan deviation) of the HM-disciplined 1542-nm laser as measured at INRIM; red line (triangles): instability of the beatnote between the fiber-disseminated signal at 1542 nm and the local 1156-nm laser, locked to it; green line (diamonds): instability of the beatnote between the 1542-nm laser and the local 1156-nm laser when a linear drift of 0.1 Hz/s is removed off-line. All measurements are taken with 0.5 Hz measurement bandwidth.

than 1 Hz, which is due to the residual fluctuations of the phase-stabilized link. The black curve represents the link contribution alone, calculated from the round-trip fiber noise, considering that the compensation is limited by the photon round-trip time into the fiber (∼ 6 ms) [35]. At Fourier frequencies higher than 0.1 Hz, the fiber-disseminated optical signal gives the main contribution to the noise and cannot be directly used for spectroscopy: this motivates the ULE-stabilization of the local 1156-nm laser. On the other hand, the long-term instability of the 1156-nm local laser emerges on long averaging times: in Fig. 2b, the green curve shows the relative frequency instability (relative frequency Allan deviation) of the beatnote between the disseminated 1542-nm laser and the local 1156-nm laser, after a linear drift (∼ 0.1 Hz/s) is removed. At averaging times > 10 s it is limited by the stochastic temperature variations of the ULE cavity to which the 1156-nm laser is locked. In this configuration, short-term instabilities of few parts in 10−14 are featured by the probe laser, still showing frequency drifts ∼ 100 mHz/s. The red line shows the relative instability of the beatnote between the disseminated 1542-nm laser and the local 1156-nm laser, when the latter is locked to the former; this represents the electronic and system noise of the comb and locking algorithm at LENS and demonstrates that the long-term stability of the 1156-nm laser can be improved by one order of magnitude already at 1000 s, achieving the 10−15level of instability. The blue line shows the instability of the 1542-nm laser disciplined to the HM, measured against an independent twin system at INRIM.

Beyond-GPS, optically-referenced spectroscopy

To demonstrate the potential of optical frequency dissem-ination in actual experiments, we performed long-term interrogation of the1S

0–3P0 clock transition (featuring

a natural linewidth of few tens of mHz) in a quantum degenerate Fermi gas of173Yb. The atomic sample is

pre-pared by means of laser-cooling and evaporative-cooling techniques, reaching temperatures as low as 50 nK. In this regime, roughly 104(spin-polarized) atoms are loaded

into a three-dimensional optical lattice, with one atom per lattice site, each being separated by 380 nm from the nearest neighbors. Due to the low temperature and fermionic nature of the particles, the Pauli exclusion prin-ciple inhibits multiply-occupied sites. The lattice depth is ∼ 30Erec, where Erec = h × 2.00 kHz stands for the

atomic recoil energy at the lattice wavelength of 759 nm and h for the Planck’s constant. The atoms are illumi-nated by a 100-ms-long pulse of 578-nm light, coming from the frequency-doubled 1156-nm probe laser. The π-polarized probe beam intensity is 10 µW/cm2, adjusted

in order to grant a reliable signal-to-noise ratio and lead-ing to a line broadenlead-ing of less than 50 Hz. The atoms are then released from the lattice, and the spectroscopic signal is extracted by observing the loss peak in the total atom number as a function of the laser frequency through resonant light absorption after a 25-ms-long time of flight.

Fig. 3a,b shows typical short-term atom loss features retrieved by this method on a total timescale of several hours. Here, each scan takes typically 20 minutes, since the experimental setup is not optimized for fast-cycle, high-precision spectroscopy. In order to stress the bene-fits of the optical link referencing, we compare the case

(4)

FIG. 3. Spectroscopy of the 1S0—3P0 173Yb clock transition. a. GPS-based measurement, with a series of 10- to

30-minutes-long scans taken at different starting times during the same day (see legend). b. Same as in a, but with the GPS reference replaced by the optical link. c, d. Long-term addressing of the clock transition (5.2 hours), used for extracting its absolute frequency (see text). The error bars indicate the standard deviation of the mean over approximately 10 repeated measurements. The lines are fits with Lorentzian functions. The zero values for the horizontal scales are chosen arbitrarily.

of (a) laser referenced to the GPS standard and (b) laser stabilized to the optical link. The difference is remark-able. In the GPS configuration case, drifts larger than 1 kHz are observed, being the linewidth/lineshape heav-ily influenced by the relative direction of scan and laser drifts on the observation timescale. The spectra show typical Lorentzian full-width-at-half-maximum (FWHM) linewidths below 100 Hz. On the other hand, in the opti-cal link case no appreciable fluctuations/drifts arise. Here the residual laser fluctuations are well below the typically observed linewidth, not exceeding tens of Hz FWHM, limited by the short term stability of the local laser [34], which is comparable to the power broadening.

The remote long-term stabilization of the interrogation laser is a keynote result for the vast majority of experi-mental setups that require a high degree of stability: the local sample can be employed as a “tool”, rather than as a frequency reference (as happening, e.g, in optical clocks), and in turn the local laser can be used as a co-herent manipulation device for the sample itself, rather than as a probe. Specifically, for experiments involving AEL atoms, this implies the possibility of building new quantum simulators involving the manipulation of the electronic degree of freedom, or realizing implementation of quantum computing protocols in a steady, reliable way. As a matter of fact, in a typical experimental setup as the one at LENS, which is designed for those tasks (and not as an optical atomic clock), a direct lock of the local laser frequency on the clock atomic transition is not a viable choice. Indeed, the experimental cycle (devoted to the manipulation of a quantum degenerate gas) can last from several seconds up to few minutes. If the local probe laser were locked on the atomic transition, this rather long cycle would cause a large deterioration of the laser frequency stability because of the Dick effect [2].

Absolute frequency measurement of the 173Yb clock transition

By exploiting the optical dissemination, we have measured the absolute frequency of the1S

0—3P0 clock transition

with respect to the remote Cs fountain. We collected six independent measurements spread over a period of three months, each consisting of a complete scan of the transition, with typical linewidths of 50 Hz FWHM (see Fig. 3c). The runs had different duration, ranging from 2000 s to 19000 s, for a total measurement time of 40000 s (∼ 11 hours). The measured frequency ν0 of the173Yb 1S

0—3P0 transition is 518 294 576 845 268 (10) Hz; this

improves the uncertainty of a previous direct measurement [30] by a factor 400, with an agreement between the two values. Consequently, combined with other previous measurements [2], we also improve the knowledge of the isotope shifts of the1S0—3P0 transition, whose values

are: ν0171− ν173 0 = 1 259 745 597(10) Hz and ν 173 0 − ν 174 0 =

551 536 050(10) Hz. Remarkably, this accuracy would not be reachable through a GPS-based measurement.

Table 1 reports the uncertainty budget, along with the systematic biases that have been corrected to obtain the unperturbed173Yb clock transition frequency. We

calcu-late the total uncertainty on the absolute frequency value as the quadratic sum of statistical and systematic contribu-tions. The statistical uncertainty (Type A) is the weighted composition of four contributions: the Lorentzian fit, the Cs fountain instability and the beatnotes instability of the optical combs at INRIM and LENS. The total type A uncertainty for the reported measurement is 1.9 Hz (4×10−15fractional frequency uncertainty), where we

con-sidered a Student statistic for the data and a confidence level of 90% due to the limited number of measurements.

(5)

Blackbody radiation −1.24 0.05

Probe laser intensity – 0.00015

Gravitational redshift 2.277 0.005

Total Type B (***) 9

Total (***) 0.5 10

(*) Depending on the measurement run.

(**) Weighted uncertainty of all measurements with Student 90% confidence level.

(***) Typically 0.1 Hz; in some measurements the phase-slips uncer-tainty was 5 Hz for technical problems; in the total type B we considered the worst-case scenario.

sources: the Cs fountain accuracy, the phase slips of the optical link and the physical effects perturbing the Yb clock transition. The contribution coming from the Cs fountain accuracy (2 × 10−16) was 0.1 Hz [32], whilst the contribution by the phase-slips on the fiber link was typically < 0.1 Hz (1.5 × 10−16), measured by redundant beatnote tracking.

In order to provide an unbiased value for the absolute frequency of the173Yb clock transition, it is necessary to

evaluate the local systematics. A quantization magnetic field is applied in order to resolve the Zeeman structure of the line, arising from the173Yb nuclear spin I = 5/2. The transition frequency measurement is obtained by a Lorentzian fit of the two resonances corresponding to Zeeman components mI = ±5/2, reported in Fig. 3d,

and then by averaging their observed values in order to wash out the first-order magnetic field contribution to the transition frequencies. The average first-order splitting of the two components is 1712(3) Hz, hence, according to the sensitivity coefficient of 2I × 113 Hz/G [36], the value of the bias magnetic field is B = 3.031(5) G. This value is used to correct for the quadratic Zeeman shift of the transition frequency. The quadratic sensitivity is experimentally measured to be −0.064(2) Hz/G2, leading

to a bias of −0.59(3) Hz in the measurements.

In order to limit the effects of the differential light shift induced on the1S

0and3P0 levels by the trapping light

potential, the optical lattice has been set at the Stark-shift-free “magic” wavelength around 759 nm [2]. The value of the magic frequency has been measured by using the

the transition: according to the sensitivity of 15 mHz/mW cm−2 [38] and to the laser intensity of 10 µW/cm2, the light shift is 0.15 mHz, kept as uncertainty

contribution.

Collisional shifts are also negligible, since the spin-polarized Fermi gas fills the 3D optical lattice with at most one atom per site.

The SI second is defined at the geoid gravity potential, hence the frequency reference disseminated from INRIM is corrected for the gravitational redshift [39]. The or-thometric height of the LENS laboratory on the geoid was measured in a dedicated geodetic campaign [40], and the resulting gravitational redshift is 4.81(1) × 10−15 or

2.277(5) Hz (see Methods for details).

Conclusions

In conclusion, we have demonstrated that long-haul fiber-based optical frequency dissemination is a reliable tool for remote end-users to perform high-precision procedures well beyond the ultimate capabilities of GPS dissemina-tion. As a proof, ultrastable laser light at 1542 nm, traced to the SI second, is transferred from the Italian National Metrology Institute to the European Laboratory for Non Linear Spectroscopy, across a 642-km-long fiber link. This is used as an absolute frequency reference for a metro-logical measurement in a non-metrometro-logical experiment at LENS, enabling a stable, long-term interrogation of the sample with metrological traceability and the abso-lute measurement of the173Yb1S

0—3P0 clock transition

frequency with a combined uncertainty of 10 Hz, that also improves the previously published result [30] by a factor 400. The inherent uncertainty of the dissemination channel is limited to 2 Hz, corresponding to a relative uncertainty of 4 × 10−15. Noticeably, this beyond-GPS ac-curacy is achieved in timescales as short as few hours and can be reliably reproduced over time periods of several months in a non-metrological end-user laboratory.

This long-haul optical frequency dissemination features a potential outcome on a wealth of applications ranging from scientific research to industrial development and production processes. Besides the intrinsic interest of our work as a proof of real effectiveness of this

(6)

dissemina-tion technique, our results could be readily exploited for the investigation of many-body quantum physics in AEL atomic systems [18, 41], and for the application of novel promising quantum information schemes [23] where the frequency precision and the coherence of a manipulation laser on typical experimental timescales are of the highest importance. Furthermore, future applications exploiting the quantum nature of optical links have recently been envisioned, allowing for the realization of a “quantum network of clocks” with quantum-enhanced capabilities [42]. This upgrade to the “quantum level” would also represent a major breakthrough from a non-metrological point of view, allowing for quantum optics experiments over truly macroscopic distances, for both foundational tests and innovative technological applications.

Acknowledgements

We thank P. C. Pastor, P. De Natale, P. Lombardi and C. Sias for discussions and experimental contributions

and A. Godone and M. Pizzocaro for a careful reading of the manuscript. This work has been supported by research grants MIUR PRIN2012 project AQUASIM, EU FP7 project SIQS and MIUR ”Progetti Premiali” project LIFT.

Author contributions

(*) These authors contributed equally to the work. C. C., M. F, A. M., G. A. C., F. L., D. C. realized and operated the link and Cs fountain primary frequency standard and performed the measurements at INRIM. G. C., L. L., F. P., M. S. d. C., M. M., G. P., L. F., J. C., M. I. set up the regeneration stage, took care of experimental spectroscopic apparatus and performed the measurements at LENS.

All authors contributed to the analysis of the data, to the discussion of the results, and to the writing of the manuscript.

(7)

quency correction on an acousto-optic modulator (AOM) every 100 ms, on a bandwidth of 40 mHz. The phase-lock to the hydrogen maser slightly degrades the short-term stability, leading to an Allan deviation of 1.5 × 10−14 at 1 s measurement time. The laser is then sent to LENS through a 642-km-long fiber, phase-stabilized according to the Doppler noise cancellation scheme. A complete description of the setup can be found in [8]; the round-trip beatnote is continuously tracked by two independent voltage-controlled oscillators (VCO); one of them feeds the PLL used for the link stabilization, the other is used for the phase-slips detection. To this purpose, the VCOs outputs are synchronously counted and all measurements differing by more than 0.4 Hz identify the occurrence of phase jumps. This threshold is chosen according to the minimum slips amplitude, i.e. 1 cycle, that is de-tected as a 1-Hz frequency outlier on a gate time of 1 s. Thanks to the low phase-slips rate (few per hour) and to their low amplitude (typically, less than 2 cycles), a thor-ough removal of the phase-slips is not necessary in this experiment, and it is enough to keep trace of their occur-rence and amplitude. An overall uncertainty is assigned off-line to the disseminated frequency by measuring the discrepancy between the two VCO-frequencies.

Regeneration and fiber phase-noise cancellation. At the output stage of the fiber link at LENS, a clean-up narrow-line diode laser, driven by a home-made low-noise current driver, is phase-locked to the incoming radiation on a bandwidth of 100 kHz through direct current feed-back on the laser chip. This stage amplifies the incoming link signal (∼ 40 nW), rejecting the wideband noise due to the build-up of Amplified Spontaneous Emission of the

Analog/digital frequency lock to remote refer-ence. In the end-user lab, a frequency comb serves as a frequency bridge between the 1542-nm regenerated refer-ence laser and the 1156-nm probe laser. The 777597th tooth of the comb spectrum is beaten with the incoming radiation. The beatnote is stabilized on a bandwidth of 250 kHz by adjusting the comb repetition rate with an intra-cavity electro-optic modulator. Also, a portion of the comb spectrum around 1156 nm is separately filtered, amplified and beaten against the local cavity-stabilized laser. This beatnote is acquired with a frequency counter over a 30 s gate time and stabilized by a digital feedback loop. The latter relies on a PC-based proportional-integral feedback scheme, and controls a Direct Digital Synthesis board, so that the frequency of the frequency-doubled laser light at 578 nm can be adjusted through an AOM before illuminating the atomic sample (see Fig. 1).

Geodetic corrections. The orthometric height above the geoid in Turin at the caesium fountain location is 238.7(1) m and the gravity correction is limited by the value of the geoid at 1 × 10−17 in terms of equivalent relative frequency. The orthometric height in Florence is 40.3(1) m; hence the frequency correction, using the sensitivity of 1.09 × 10−16/m in the near-Earth approxi-mation, is 4.39(1) × 10−15or 2.277(5) Hz. Incidentally, if

we consider that the two orthometric heights have been evaluated on the same geopotential model [43], the uncer-tainty could be further reduced as the geoid potential is rejected, and we can directly consider the gravity poten-tial difference of the two locations. In this case, the height difference uncertainty is reduced to just 3 cm, equivalent to 3 × 10−18 relative frequency uncertainty or 2 mHz.

[1] Lombardi, M. The Use of GPS Disciplined Oscillators as Primary Frequency Standards for Calibration and Metrol-ogy Laboratories, NCSLI Measure J. Meas. Sci. 3 (3), 56–65 (2008).

[2] Ludlow, A. D., Boyd, M. M., Ye, J. & Schmidt, P. O. Op-tical atomic clocks. Rev. Mod. Phys. 87, 637–701 (2015).

[3] Ushijima, I., Takamoto, M., Das, M., Ohkubo, T. & Katori H. Cryogenic optical lattice clocks. Nature Photon. 9, 185–189 (2015).

[4] Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley S. L. & Ye, J. An optical lattice clock with accuracy and stability

(8)

at the 10−18level. Nature 506, 71–75 (2014).

[5] Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W. & Ludlow, A. D. An atomic clock with 10−18instability, Science 341, 1215–1218 (2013).

[6] Calonico, D., Inguscio, M. & Levi, F. Light and the distribution of time. EPL 110, 40001 (2015).

[7] Droste, S., Ozimek, F., Udem, T., Predehl, K., H¨ansch, T. W., Schnatz, H., Grosche, G. & Holzwarth, R. Optical-frequency transfer over a single-span 1840 km fiber link. Phys. Rev. Lett. 111, 110801 (2013).

[8] Calonico, D., Bertacco, E. K., Calosso, C. E., Clivati, C., Costanzo, G. A., Frittelli, M., Godone, A., Mura, A., Poli, N., Sutyrin, D. V., Tino, G. M., Zucco, M. E. & Levi, F. High-accuracy coherent optical frequency transfer over a doubled 642-km fiber link. Appl. Phys. B 117, 979-986 (2014).

[9] Lopez, O., Haboucha, A., Chanteau, B., Chardonnet, C., Amy-Klein, A. & Santarelli, G. Ultra-stable long distance optical frequency distribution using the Internet fiber network. Opt. Express 20, 23518–23526 (2012).

[10] Fujieda, M., Kumagai, M., Nagano, S., Yamaguchi, A., Hachisu, H. & Ido, T. All-optical link for direct compari-son of distant optical clocks. Opt. Express 19, 16498–16507 (2011).

[11] Yamaguchi, A., Fujieda, M., Kumagai, M., Hachisu, H., Nagano, S., Li, Y., Ido, T., Takano, T., Takamoto, M. & Katori, H. Direct comparison of distant optical lattice clocks at the 10−16 uncertainty. Appl. Phys. Express 4, 082203 (2011).

[12] Matveev, A., Parthey, C. G., Predehl, K., Alnis, J., Beyer, A., Holzwarth, R., Udem, T., Wilken, T., Kolachevsky, N., Abgrall, M., Rovera, D., Salomon, C., Laurent, P., Grosche, G., Terra, O., Legero, T., Schnatz, H., Weyers, S., Altschul, B. & H¨ansch, T. W. Precision measurement of the hydrogen 1S2S frequency via a 920-km fiber link. Phys. Rev. Lett. 110, 230801 (2013).

[13] Clivati, C., Costanzo, G. A., Frittelli, M., Levi, F., Mura, A., Zucco, M., Ambrosini, R., Bortolotti, C., Perini, F., Roma M. & Calonico, D. A coherent fiber link for very long baseline interferometry. IEEE Trans. Ultrason. Fer-roelectr. Freq. Control 62, 1907–1912 (2015).

[14] Droste, S., Grebing, C., Leute, J., Raupach, S. M. F., Matveev, A., H¨ansch, T. W., Bauch, A., Holzwarth, R. & Grosche, G. Characterization of a 450-km baseline GPS carrier-phase link using an optical fiber link. New J. Phys. 17, 083044 (2015).

[15] Lisdat, C. et al. A clock network for geodesy and funda-mental science. arXiv:1511.07735 (2015).

[16] Bjerhammar, A. On a relativistic geodesy. B. Geod. 59, 207–220 (1985).

[17] Argence, B., Chanteau, B., Lopez, O., Nicolodi, D., Ab-grall, M., Chardonnet, C., Daussy, C., Darqui´e, B., Le Coq Y. & Amy-Klein, A. Quantum cascade laser fre-quency stabilization at the sub-Hz level. Nature Photon. 9, 456–460 (2015).

[18] Gorshkov, A. V., Hermele, M., Gurarie, V., Xu, C., Juli-enne, P. S., Ye, J., Zoller, P., Demler, E., Lukin, M. D. & Rey, A. M. Two-orbital SU (N ) magnetism with ultracold alkaline-earth atoms. Nature Phys. 6, 289–295 (2010). [19] Cazalilla, M. A. & Rey, A. M. Ultracold Fermi gases with

emergent SU(N ) symmetry. Rep. Prog. Phys. 77, 124401 (2014).

[20] Taie, S., Yamazaki, R., Sugawa, S. & Takahashi, Y. An

SU(6) Mott insulator of an atomic Fermi gas realized by large-spin Pomeranchuk cooling. Nature Phys. 8, 825–830 (2012).

[21] Pagano, G., Mancini, M., Cappellini, G., Lombardi, P., Sch¨afer, F., Hu, H., Liu, X.-J., Catani, J., Sias, C., Ingus-cio, M. & Fallani, L. A one-dimensional liquid of fermions with tunable spin. Nature Phys. 10, 198–201 (2014). [22] Mancini, M., Pagano, G., Cappellini, G., Livi, L., Rider,

M., Catani, J., Sias, C., Zoller, P., Inguscio, M., Dalmonte, M. & Fallani, L. Observation of chiral edge states with neutral fermions in synthetic Hall ribbons. Science 349, 1510–1513 (2015).

[23] Daley, A. J., Boyd, M. M., Ye, J. & Zoller, P. Quantum computing with alkaline earth atoms. Phys. Rev. Lett. 101, 170504 (2008).

[24] Daley, A. J. Quantum computing and quantum simulation with Group-II atoms. Quantum Inf. Process. 10, 865–884 (2011).

[25] Cappellini, G., Mancini, M., Pagano, G., Lombardi, P., Livi, L., Siciliani de Cumis, M., Cancio, P., Pizzocaro, M., Calonico, D., Levi, F., Sias, C., Catani, J., Inguscio, M. & Fallani, L. Direct Observation of Coherent Interorbital Spin-Exchange Dynamics. Phys. Rev. Lett. 113, 120402 (2014).

[26] Scazza, F., Hofrichter, C., H¨ofer, M., De Groot, P. C., Bloch I. & F¨olling, S. Observation of two-orbital spin-exchange interactions with ultracold SU(N)-symmetric fermions. Nature Phys. 10, 779–784 (2014).

[27] Zhang, X., Bishof, M., Bromley, S. L., Kraus, C. V., Safronova, M. S., Zoller, P., Rey, A. M. & Ye, J. Spectro-scopic observation of SU(N )-symmetric interactions in Sr orbital magnetism. Science 345, 1467–1473 (2014). [28] Pagano, G., Mancini, M., Cappellini, G., Livi, L., Sias,

C., Catani, J., Inguscio, M. & Fallani, L. A strongly interacting gas of two-electron fermions at an orbital Feshbach resonance. Preprint arXiv:1509.04256 (2015). [29] H¨ofer, N., Riegger, L., Scazza, F., Hofrichter, C.,

Fer-nandes, D. R., Parish, M. M., Levinsen, J., Bloch, I. & F¨olling, S. Observation of an orbital interaction-induced Feshbach resonance in 173-Yb. Preprint arXiv:1509.04257 (2015).

[30] Hoyt, C. W., Barber, Z. W., Oates, C. W., Fortier, T. M., Diddams, S. A. & Hollberg, L. Observation and ab-solute frequency measurements of the1S

0—3P0 optical

clock transition in neutral ytterbium. Phys. Rev. Lett. 95, 083003 (2005).

[31] Clivati, C., Mura, A., Calonico, D., Levi, F., Costanzo, G. A., Calosso, C. E. & Godone, A. Planar-waveguide exter-nal cavity laser stabilization for an optical link with 10−19 frequency stability. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 58, 2582–2587 (2011).

[32] Levi, F., Calonico, D., Calosso, C. E., Godone, A., Mi-calizio, S. & Costanzo, G. A. Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountain. Metrologia 51, 270–284 (2014).

[33] Pizzocaro, M., Costanzo, G. A., Godone, A., Levi, F., Mura, A., Zoppi, M. & Calonico, D. Realization of an ultrastable 578-nm laser for an Yb lattice clock. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 59, 426–431 (2012).

[34] Cappellini, G., Lombardi, P., Mancini, M., Pagano, G., Pizzocaro, M., Fallani, L. & Catani, J. A compact ul-tranarrow high-power laser system for experiments with 578 nm ytterbium clock transition. Rev. Sci. Instrum. 86,

(9)

Riferimenti

Documenti correlati

Subsequently the analysis considers the jurisprudence and doctrine development during the second post-war period, with the progressive development, beside the traditional thesis of

More in particular, Ehrlich employs an approach that is very much in accord with my research question, since it detects not only legal-norms but everything that is related and

We performed the spectral purity transfer between the 1156 nm ultrastable laser used to probe the clock transition of the 171 Yb optical lattice clock and a 1542 nm diode laser,

It doesn't only indicate the assumption of suffering and death from God in the person of the Son, but it also and exactly indicates the victory of love over death, the enthronement

(2004) evaluated the star formation rate for a large sample of local galaxies and found that, in- triguingly, galaxies separate in different region of the SFR vs M∗ plane: most

∙ Embarked on MSF’s largest knowl- edge transfer effort, with more than 800 MSF staff trained on safe Ebola management in headquarters, as well as 250 people from other

Parole chiave: Regno di Napoli, Santa Sede, concordato del 1741, Benedetto XIV, tassazione dei beni ecclesiastici.. SOMMARI

In table 1 we present the results for the efficency of the code to determine the magnetic field strength: ∆B represents the dif- ference between the known value of the mag-