• Non ci sono risultati.

ACOUSTICS part - 2 Sound Engineering Course

N/A
N/A
Protected

Academic year: 2022

Condividi "ACOUSTICS part - 2 Sound Engineering Course"

Copied!
27
0
0

Testo completo

(1)

Angelo Farina

Dip. di Ingegneria Industriale - Università di Parma Parco Area delle Scienze 181/A, 43100 Parma – Italy

angelo.farina@unipr.it www.angelofarina.it

ACOUSTICS part - 2

Sound Engineering Course

(2)

Decibels

Decibels

(3)

The Decibel scale (1):

The Decibel scale (1):

What are decibels, and why are they used?:

The physical quantities related to sound amplitude have an huge dynamic range:

• 1 pW/m

2

(hearing threshold)  1 W/m

2

(pain threshold) [10

12

ratio]

• 20 Pa (hearing threshold)  20 Pa (pain threshold) [10

6

ratio]

The human perception compresses such wide dynamic ranges in a much lesser variable perception. Hence a logirthmic compression is employed, for mimicing the human perception law.

The advanatge of empoloying a logarithmic scale is to “linearize”

the perceived loudness perception (roughly, the loudness doubles

every increase of intensity of a factor of 10);

(4)

The Decibel scale (2):

The Decibel scale (2):

The sound pressure level “Lp” or SPL, is defined as:

• Lp = 10 log p2/prif2 = 20 log p/prif (dB) @ prif = 20 Pa The particle velocity level “Lv” is defined as:

• Lv = 10 log v2/vrif2 = 20 log v/vrif (dB) @ vrif = 50 nm/s.

The sound intensity level “LI” is defined as:

• LI = 10 log I/Irif (dB) @ Irif = 10-12 W/m2. The energy density level “LD” is defined as:

• LD = 10 log D/Drif (dB) @ Drif = 3·10-15 J/m3. In the simple case (plane progressive wave) (oco = 400 rayl):

• p/u= oco I = p2/oco =D·c0 => hence Lp = Lv = LI = LD

(5)

The Decibel scale (3):

The Decibel scale (3):

The sound power level “LW” is defined as:

• LW = 10 log W/Wrif (dB) @ Wrif = 10-12 W.

But, while the fiorst 4 levels have all the sam emenaing (how loud a sound is perceived), and assume the very same value in the simple case of the plane, progressive wave, instead the Sound Power Level value is generally different, and possibly much larger than the first 4 values!

In the simple case of plane, progressive wave (piston having area S at the entrance of a pipe), the relationship among sound power level and sound intensity level is::

• LW = LI + 10 log S/So =LI + 10 log S (dB)

If the surface area S represent the total surface over which the power flows away from the source, the above relationship is substantially always valid, even if the radiated sound field is NOT a plane progresive wave.

(6)

The human auditory system

The human auditory system

(7)

The human ear The human ear

Cochlea Internal ear

Structure of human ear, divided in external ear, medium ear and

internal ear

(8)

Frequency selectivity of Cochlea Frequency selectivity of Cochlea

A cross-section of the cochlea shows a double membrane dividing it in two ducts

the membrane has the capability of resonating at different frequencies, high at the begininning, and

progressively lower towards the end of the ducts.

However, a low frequency sound also stimulates the initial part of the

cochlea, which si sensible to high frequency. Also the opposite occurs, but at much lesser extent. This is the frequency masking effect.

(9)

The Cochlea The Cochlea

• Each point of the cochlea reacts maximally to one given frequency, as shown here for the human cochlea:

(10)

Frequency-dependent sensitivity of human ear:

Frequency-dependent sensitivity of human ear:

The sensitivity of the human hearing system is lower at medium-low frequencies and at very high frequencies.

The diagram shows which SPL is required for creating the same loudness perception, in phon, at different frequencies

The human ear perceives with diffrent loudness sounds of same SPL at different frequencies.

(11)

The new “equal Loudness” ISO curves:

The new “equal Loudness” ISO curves:

In 2003 the ISO 226 standard was revised. In the new standard, the iso- phon curves are significantly more curved:

With these new curves, a sound of 40 dB at 1000 Hz corrisponds to a sound of 64 dB at 100 Hz (it was just 51 dB before).

(12)

Weighting filters:

Weighting filters:

For making a rough approximation of human variable sensitivity with frequency, a number of simple filtering passive networks were defined, named with letters A through E, initially intended to be used for increasing SPL values. Of them, just two are still in use nowadays:

• “A” weighting curve, employed for low and medium SPL values (up to 90 dB RMS) [dB(A)].

• “C” weighting curve, employed for large amplitude pulsive sound peaks (more than 100 dB peak) [dB(C)].

(13)

““A weighting” filter:A weighting” filter:

Table of A-weighting factors to be used in calculations

(14)

Time masking Time masking

After a loud sound, for a while, the hearing system remains “deaf “to weaker sounds, as shown by the Zwicker masking curve above.

The duration of masking depends on the duration of the masker, its amplitude and its frequency.

(15)

Frequency masking Frequency masking

A loud pure tone create a “masking spectrum”. Other tones which fall below the masking curve are unadible. The masking curve is asymmetric (a tone more easily masks higher frequencies)

(16)

Sound pressure measurement:

Sound pressure measurement:

sound level meters

sound level meters

(17)

The sound level meter The sound level meter

A SLM measures a value in dB, which is the sound pressure level evaluated by the RMS value of the sound pressure, prms averaged over the measurement time T:

with

2

0

log

10 

 

 

p

Lp prms prms T

T p t dt

0

2( ) 1

(18)

Structure of a sound level meter:

Structure of a sound level meter:

The SLM contains a preamplifier for adjusting the full scale value, a weighting network or a bank of pass-band filters, a “true RMS” detector which can operate either with linear averaging over a fixed measurement time, or a “running exponential averaging” with three possible “time constants”, and a display for showing the results.

(19)

The Equivalent Continuous Level (L The Equivalent Continuous Level (Leqeq):):

T

rif T

eq dt

p t p L T

0 2 2 ,

) ( log 1

10

The continuous equivalent level Leq (dB) is defined as:

where T is the total measurement time, p(t) is the instantaneous pressure value and prif is the

reference pressure • Leq,T  dB (linear frequency weighting)

• LAeq,T  dB(A) (“A” weighting)

• Please note: whatever the frequency weighting, an Leq is always

measured with linear time weighting over the whole measurement time T.

(20)

““running” exponential averaging: Slow, Fast, Impulserunning” exponential averaging: Slow, Fast, Impulse

Instead of measuing the Equivalent Level over the whole measurement time T, the SLM can also operate an “exponential” averaging over time, which continuosly displays an updated value of SPL, averaged with exponentially- decaying weighting over time according to a time constant TC :

in which the time constant TC can be:

• TC = 1 s – SLOW

• TC = 125 ms – FAST

• TC = 35 ms for raising level, 1.5 s for falling level – IMPULSE

In exponential mode, a SLM tends to “forget” progressively past events……

Instead, in linear mode, the result of the measurment is the same if a loud event did occur at the beginning or at the end of the measurement time

 1

SLOW

Lin, 1s

 

 

0

2

( )

1 e p t dt

p T

Tc

t

c

rms

 

(21)

Calibration at 1 Pa RMS (94 dB) Calibration at 1 Pa RMS (94 dB)

The calibrator generates a pure tone at 1 kHz, with RMS pressure of 1 Pa:

(22)

SPL analysis of a calibrated recording SPL analysis of a calibrated recording

The software computes a time chart of SPL with the selected time constant:

(23)

Sound level summation in dB (1):

Sound level summation in dB (1):

“Incoherent” sum of two “different” sounds:

Lp

1

= 10 log (p

1

/p

rif

)

2

(p

1

/p

rif

)

2

= 10

Lp1/10

Lp

2

= 10 log (p

2

/p

rif

)

2

(p

2

/p

rif

)

2

= 10

Lp2/10

(p

T

/p

rif

)

2

= (p

1

/p

rif

)

2

+ (p

2

/p

rif

)

2

= 10

Lp1/10

+ 10

Lp2/10

Lp

T

= Lp

1

+ Lp

2

= 10 log (p

T

/p

rif

)

2

= 10 log (10

Lp1/10

+ 10

Lp2/10

)

(24)

Sound level summation in dB (2):

Sound level summation in dB (2):

“incoherent” sum of two levels

• Example 1:

L

1

= 80 dB L

2

= 85 dB L

T

= ? L

T

= 10 log (10

80/10

+ 10

85/10

) = 86.2 dB.

• Example 2:

L

1

= 80 dB L

2

= 80 dB

L

T

= 10 log (10

80/10

+ 10

80/10

) =

L

T

= 80 + 10 log 2 = 83 dB.

(25)

Sound level subtraction in dB (3):

Sound level subtraction in dB (3):

Level difference

• Example 3:

L1 = 80 dB LT = 85 dB L2 = ? L2 = 10 log (1085/10 - 1080/10) = 83.35 dB

(26)

Sound level summation in dB (4):

Sound level summation in dB (4):

“Coherent” sum of two (identical) sounds:

Lp

1

= 20 log (p

1

/p

rif

) (p

1

/p

rif

) = 10

Lp1/20

Lp

2

= 20 log (p

2

/p

rif

) (p

2

/p

rif

) = 10

Lp2/20

(p

T

/p

rif

) = (p

1

/p

rif

)+ (p

2

/p

rif

) = 10

Lp1/20

+ 10

Lp2/20

Lp

T

= Lp

1

+ Lp

2

= 10 log (p

T

/p

rif

)

2

= 20 log (10

Lp1/20

+ 10

Lp2/20

)

(27)

Level summation in dB (5):

Level summation in dB (5):

“coherent” sum of levels

• Example 4:

L

1

= 80 dB L

2

= 85 dB L

T

= ? L

T

= 20 log (10

80/20

+ 10

85/20

) = 88.9 dB.

• Example 5:

L

1

= 80 dB L

2

= 80 dB

L

T

= 20 log (10

80/20

+ 10

80/20

) =

L

T

= 80 + 20 log 2 = 86 dB.

Riferimenti

Documenti correlati

Abstract (IT): Dalla centralità dell’evento del North Caroline (1952) emergono linee espressive, teoriche e di politica culturale del teatro-mediale che matura a

Anche questi oggetti possono essere percepiti come bellissimi e darci piacere, oppure possono stimolare il nostro interesse / curiosità, ma in qualche modo il nostro rapporto con

As the earthquake duration is defined as the time point at which the envelope encounters the rms-noise level, we can numerically estimate the corresponding

Sound can be seen as a form of energy propagation due to rapid repetition of compresion and exopansion of an elastic medium; the energy is originated from a

The spectrum of the sound source must be known for assessing the insertion loss value at each frequency, and then recombining the values at all the frequencies

A field is said to be semi-reverberant when it contains both free field zones (near the source, where the direct sound prevails) and reverberant field zones (near the

• Dave Malham suggested to represent also the source directivity with a set of spherical harmonics, called O-format - this is perfectly reciprocal to the representation of the

Sound can be seen as a form of energy propagation due to rapid repetition of compresion and exopansion of an elastic medium; the energy is originated from a