The primary role of tendons is to transmit contractile forces to the skeleton to generate joint movement. In doing so, however, tendons do not behave as rigid bodies.

In this chapter, the mechanical behavior of tendons and its major determinants and implications are reviewed.

In Vitro Measurements

Most of our knowledge of the mechanical properties of tendons comes from isolated material testing. Two methods have traditionally been used in biomechanics investigations: 1) The free-vibration method, which is based on quantifying the decay in oscillation amplitude that takes place after a transient load is applied to a spec- imen [1–3]; and 2) tensile testing methodologies, in which the specimen is stretched by an external force while both the specimen deformation and the applied force are recorded [2,4–6]. The latter methodology seems to be preferable, mostly because it is considered to mimic ade- quately the way that loading is imposed on tendons in real life [7–14].

A tensile testing machine is composed of an oscillat- ing actuator and a load cell (see Figure 2-1). The tendon specimen studied is gripped by two clamps, a static one mounted on the load cell and a moving one mounted on the actuator. The actuator is then set to motion while the load cell records the tension associated with the stretch- ing applied. The tensile deformation of the specimen is taken from the displacement of the actuator, in which case the deformation of the whole specimen is quantified, or by means of an extensometer, in which case deforma- tion measurements are taken over a restricted region of the whole specimen.

A typical force-deformation plot of an isolated tendon is shown in Figure 2-2. Generally, in force-deformation curves, slopes relate to stiffness (N/mm), and areas to energy (J). In elongation-to-failure conditions, 4 different regions can be identified in the tendon force-deformation

curve. Region I is the initial concave portion of the curve, in which stiffness gradually increases; it is referred to as the tendon “toe” region. Loads within the toe region elongate the tendon by reducing the crimp angle of the collagen fibers at rest, but they do not cause further fiber stretching. Hence, loading within the toe region does not exceed the tendon elastic limit, and subsequent unload- ing restores the tendon to its initial length. Further elon- gation brings the tendon into the “linear” Region II, in which stiffness remains constant as a function of elonga- tion. In this region, elongation is the result of stretching imposed in the already aligned fibers by the load imposed in the preceding toe region. At the end point of this region, some fibers start to fail. Thus, A) the tendon stiff- ness begins to drop; and B) unloading from this point does not restore the tendon’s initial length. Elongation beyond the linear region brings the tendon into Region III, where additional fiber failure occurs in an unpre- dictable fashion. Further elongation brings the tendon into Region IV, where complete failure occurs [4,5,15–18].

Although Regions I, II, III, and IV are apparent in tendon force-deformation curves during elongation-to- failure conditions, the shape of the curves obtained differs between specimens. These differences can be accounted for to a great extent by interspecimen dimen- sional differences. For example, tendons of equal lengths but different cross-sectional areas exhibit different force-deformation properties, and thicker tendons are stiffer. Similarly, different force-deformation curves are obtained from tendons of equal cross-sectional areas but different initial lengths, in which case shorter tendons are stiffer [5].

To account for interspecimen dimensional differences, tendon force is reduced to stress (MPa) by normalization to the tendon cross-sectional area, and tendon deforma- tion is reduced to strain (%) by normalization to the tendon original length. The tendon stress-strain curve is similar in shape to the force-deformation curve, but it

14

2

Mechanical Properties of Tendons

Constantinos N. Maganaris and Marco V. Narici

(2)

reflects the intrinsic material properties rather than the structural properties of the specimen.

The most common material variables taken from a stress-strain curve under elongation-to-failure conditions are Young’s modulus (GPa), ultimate stress (MPa), ulti- mate strain (%), and toughness (J/kg). Young’s modulus is the product of stiffness multiplied by the original length-to-cross-sectional area ratio of the specimen.

Experiments on several tendons indicate that the Young’s modulus reaches the level of 1 to 2 GPa at stresses exceeding 30 MPa [5,11,12,19]. Ultimate tendon stress (i.e., stress at failure) values in the range of 50 to 100 MPa are generally reported [5,11,12,17]. Ultimate tendon strain (i.e., strain at failure) values of 4% to 10% have been reported [5,16,17]. The tendon toughness (i.e., work done on the tendon until failure) values reported are in the range of 1000 to 4500 J/kg [12].

If a tendon is subjected to a tensile load, the tendon does not behave perfectly elastically, even if the load applied is less than that required to cause failure. This is because the tendon collagen fibers and interfiber matrix possess viscous properties [20,21]. Due to the presence of viscosity, the entire tendon exhibits force-relaxation, creep, and mechanical hysteresis [2,4,5,8,15,16,22].

Force-relaxation means that the force required to cause a given elongation decreases over time. The decrease in force follows a predictable curvilinear pattern until a steady-state value is achieved (see Figure 2-3). Creep is the analogous phenomenon under constant-force condi- tions. In this case, deformation increases over time curvi- linearly until a steady state value is reached. In both force-relaxation and creep, the decrease in magnitude of

load cell

clamp

tendon specimen

clamp displacement

Figure 2-1. Diagram of an apparatus for tendon tensile testing.

Force

Deformation

I II III IV

Figure 2-2. Typical force-elongation curve of a tendon pulled by a load exceeding the tendon elastic limit. I, toe region; II, linear region; III and IV, failure regions.

A

B

C Force

Force

force application

Time

Deformation

Deformation force application

Time

hysteresis

Figure 2-3. (A) Typical force-relaxation curve in a tendon. The force required to cause a given deformation decreases over time. (B) Typical creep curve in a tendon. The deformation caused by a given force increases over time. (C) Typical mechan- ical hysteresis in a tendon. The arrows indicate loading and unloading directions during a test with a tensile load within the elastic limit of the tendon. The area of the loop between the loading and unloading curves relative to that underneath the loading curve represents the fraction of strain energy lost as heat by the tendon viscous damping.

(3)

the variable studied reflects the viscous component of the tendon, and the steady-state values reflect the elastic com- ponent of the tendon. The presence of mechanical hys- teresis is retrieved in load-deformation plots during loading and subsequent unloading of the specimen [2,6,8,12]. Larger tendon deformations are taken during recoil than stretch at given loads, yielding a loop (the hys- teresis loop) between the curves in the loading and unloading directions (see Figure 2-3).The area of the loop represents the amount of strain energy lost as heat upon recoil due to the viscous component, and it is usually expressed in relative terms (%) with respect to the total work performed on the tendon during stretching.

Mechanical hysteresis values in the range of 5% to 25%

have been reported, with most values concentrated around the value of 10% [7,8,11,12,19]. The proportion of strain energy input recovered by elastic recoil is the con- verse of mechanical hysteresis, and is known as rebound resilience.This variable is, therefore, an index of the mate- rial potential for elastic energy recovery.

Several factors may account for differences in the material properties of tendons. Some differences can be attributed to interstudy methodological differences in A) tendon gripping (conventional clamps, Cryo Jaw clamps, or use of cyanoacrylate adhesive [2,6,8,11,12,23]; B) tendon deformation measurement (actuator-based measurements, extensometer-based measurements, or noncontact optical methodologies [2,6,9,11,24]; and C) tendon cross-sectional area measurement (gravimetry- based measurements, micrometry-based measurements, or mass- and density-based estimations [9,11,25]. Some studies have shown that the status of the specimen studied (e.g., preserved or fresh) and the environmental conditions during testing may also affect the mechanical response of collagenous tissue [5,26–28], thus accounting for the above variations.

Studies on the effect of several other factors on the mechanical properties of tendinous tissue have been per- formed. The major of these factors are discussed below.

Disuse

To determine the effects of disuse on tendinous tissue properties, 3 limb immobilization models have tradition- ally been employed. In most experiments, the joint is fixed at a certain position for a prolonged period of time.

Using the specimens of the contralateral, nonimmobi- lized limb as controls, postintervention comparisons are then made [5,10,29,30]. Limb suspension and denervation models have also been used [29,31]. Most studies show that immobilization results in decreased stiffness, ulti- mate strength and energy-to-failure. These changes are attributed to specimen atrophy and changes in the spec- imen material properties. Disuse-induced changes in intrinsic material properties are associated with increased

collagen turnover and reducible cross-linking, decreased glycosaminoglycan and water content, and increased nonuniform orientation of collagen fibrils [5,10,17,18, 31–33].

Physical Activity

Most of the studies report that long-term physical activity improves the tensile mechanical properties of tendons and yields opposite effects compared with disuse [5,9,10,30,34]. Increases in stiffness, ultimate strength, and energy-to-failure in response to exercise training have been reported. Dimensional changes (i.e., hypertrophy) may partly account for these changes. Increases in ultimate stress and strain, however, indicate that the improvement of mechanical properties is also associated with training-induced changes in the tendon intrinsic material properties. Such biochemical and structural changes include increased glycosaminoglycan content, decreased collagen, reducible cross-linking, and increased alignment of collagen fibers [5,10,17,18,31–33].

Anatomical Site

Since chronic physical activity enhances the mechanical properties of tendons, it would be reasonable to suggest that tendons located at anatomical sites that allow high- level and frequent loading may have enhanced proper- ties as compared with tendons loaded by low-level forces.

Examples of tendons that are frequently loaded by high- tensile loads are the tendons of the ankle plantarflexor and digital flexor muscles. These tendons are loaded by the ground impact forces during terrestrial locomotion.

At the other end of the spectrum are the tendons of the ankle dorsiflexor and digital extensor muscles. These tendons are physiologically loaded primarily by the in- series muscles that contract to enable joint displacement.

Some experimental results indicate that the location and functional role of a tendon may be associated with the tendon mechanical response [12,35], but more recent studies stand in opposition with the above notion [19,36].

Aging

Several studies have shown that aging affects the prop- erties of tendinous tissue [4,5,12,15,18,37,38]. However, some studies have shown that aging may result in intrin- sically stiffer, stronger, and more resilient tendons [12,13], while other studies have challenged these results [37–40].

This inconsistency may be partly accounted for by dif- ferences in the initial age examined. In some studies, specimens from very young subjects have been used [12,35,41]. On such occasions, changes in tissue proper- ties reflect changes occurring as a function of maturation, which may mask an actual aging effect.

(4)

Steroids

Corticosteroids have frequently been used for the treat- ment of articular inflammations. Intra-articular and intra- collagenous injections of corticosteroid may reduce the stiffness, ultimate stress, and energy-to-failure of collage- nous tissue, even after short-term administration [42–44].

These results indicate that steroids may predispose the user to tendon injuries. Furthermore, using steroids may also impair the tendon healing process after an injury [45].

In Situ and In Vivo Protocols

In vitro–based studies have made it clear that tendons do not behave as rigid elements. Reference, however, to mechanical properties of in vitro material when inter- preting in vivo function should be treated with caution.

Although frequencies met in physiological locomotion have often been used in in vitro tensile tests, three impor- tant facts raise doubts as to whether such tests can mimic or predict accurately the tendon mechanical behavior under in vivo loading conditions: 1) Fixing a fibrous struc- ture with clamps is inevitably associated with A) slippage of the outer fibers; and B) stress concentration that may result in premature fracture. 2) Many experiments have been performed using preserved tendons, which may have altered properties [26,27]. 3) Tendon loads within the physiological region have traditionally been pre- dicted from the muscle maximal stress potential, which has been treated as a constant [12,25,46]. There is exper- imental evidence, however, that maximal muscle stress is muscle-specific, with fiber composition being the major determinant factor [47–49].

Some of these problems have been circumvented by testing animal tendons in situ after the animal has been killed or anesthetized [50–53]. This has been achieved by surgically releasing the tendon from its surrounding tissues, maintaining the proximal end of the tendon attached to the in-series muscle, and having the distal bone of the muscle-tendon unit gripped by a clamp inter- faced to a load cell. The in situ muscle contracts artificially by electrical stimulation and pulls the tendon, which lengthens as a function of the contractile force applied to its proximal end in a similar fashion to that obtained when the actuator of a tensile machine pulls an isolated specimen (see Figure 2-4). The advantage of such ex- perimental protocols is that they allow assessment of the tendon and aponeurosis (i.e., intramuscular tendon) mechanical properties A) separately, and B) under phys- iological loading levels. Notwithstanding these advan- tages, the above in situ protocols are not applicable to humans. However, adapting similar principles to those used under in situ material testing has recently allowed

the development of a noninvasive method for assessing the mechanical properties of human tendons in vivo.

The method is based on real-time, sagittal-plane ultra- sound scanning of a reference point along the tendon during static contraction of the in-series muscle. The limb is fixed on the load cell of a dynamometer to record changes in muscle torque during isometric contraction (see Figure 2-5). The tensile forces generated by contrac-

distal bone

tendon

markers

load cell

muscle

proximal bone

stimulation

Figure 2-4. Experimental set-up to measure the mechanical properties of a tendon in situ. The muscle-tendon complex is intact. The proximal and distal bones are clamped. Loading is imposed by stimulation-induced muscle contraction. The resul- tant forces are measured by a load cell placed in series with the muscle-tendon complex. The resultant deformation in the tendon is obtained from off-line analysis of the displacement of markers attached on the tendon.

b

a

e c g

h

f

d i j

Figure 2-5. Experimental set-up to measure the mechanical properties of the human tibialis anterior tendon in vivo. The limb is fixed on the footplate of a dynamometer. Isometric muscle contractions are generated by stimulation, while the re- sultant displacement of the myotendinous junction is recorded in real time using ultrasonography. The load imposed is taken from the dynamometer reading. a, dynamometer footplate; b, velcro straps; c, ankle joint; d, tibialis anterior muscle; e, tibialis anterior tendon; f, myotendinous junction; g, ultrasound probe, h; percutaneous stimulating electrodes; i, knee joint; j, knee mechanical stop. (Reprinted with permission from Maganaris and Paul.)

(5)

tion pull the tendon proximally and cause a deformation, which is measured by the recorded displacement of the reference landmark in the tendon (see Figure 2-6). The load-elongation plot obtained by this method resembles in form that taken using in vitro and in situ methodolo- gies for muscle [36,54–56].

Particular attention should be paid at several stages in the measurements taken with the above in vivo method:

1) A reference marker visible in all scans recorded throughout the entire contraction must be selected. We found that the tendon proximal end in the myotendinous junction is a reliable landmark. Since the tendon is echoreflective and the muscle echoabsorptive, the myotendinous junction can be seen clearly. Repro- ducibility measurements of the displacement of the tendon distal end in the myotendinous junction as assessed by ultrasonography have yielded intra- and interobserver coefficients of variation of less than 10%

[54–57]. Other authors have used as reference markers the intersection points of fascicles in the aponeurosis of the muscle [58–62]. This approach has the disadvantage that it yields displacements not only in the tendon, but also in a part of the aponeurosis, which may have differ- ent mechanical properties than the tendon itself [52,53].

Moreover, it is practically impossible to retrieve the loca- tion of a given fascicle (and therefore a given reference landmark) once the scanning probe has been removed from the scanned limb.

2) The scanning probe must be fixed on the skin over the scanned limb [54,60–62], or an external constant point [36]. Adhesive tape has been shown to be effective in fixing the probe securely on the skin.

3) The method necessitates that the contraction of the muscle is truly isometric, i.e., no joint movement occurs.

However, this is virtually impossible because A) structures surrounding the joint deform by the loading induced by contracting the muscle, e.g. ligaments, sur- rounding muscles and fat pads, and A) the dynamometer itself has an inherent compliance. Therefore, additional measurements need to be taken to correct for un- wanted shifts in the tendon “fixed” end when the scan- ning probe is externally fixed [36]. Kinematic measure- ments of the joint angle studied during contraction can give an estimate of the shift in the tendon “fixed” end [61,62].

4) The contractile forces elicited must be transmitted entirely to the tendon. If other muscles co-contract, then the forces recorded by the dynamometer load cell do not represent the tensile load applied to the tendon. Several authors, however, have neglected this important effect [58–62]. Isolating the mechanical action of a muscle can be achieved through percutaneous electrical stimulation over the muscle’s motor points or main nerve branch [54–56].

5) To reduce force to stress and elongation to strain, the tendon initial dimensions are required. These can also be taken using ultrasonography [54,55,58]. To obtain the mechanical hysteresis of the tendon, the con- tracting muscle must relax to allow the tendon to recoil [56].

By following the above steps, we estimated the mechan- ical properties of the human tibialis anterior and

Tibialis anterior tendon Tibialis anterior muscle

Rest

Stimulation with 75V

Stimulation with 150V

1 cm

Proximal end Distal end

Figure 2-6. Ultrasound-based assessment of tendon elonga- tion. The sonographs shown were taken over the tibialis anterior myotendinous junction of a subject at rest (top), and electrical stimulation of the tibialis anterior muscle at 75 V (middle) and 150 V (bottom). The white arrow in each scan points to the tibialis anterior tendon end in the myotendinous junction. Notice the displacement of this reference landmark in the transition from rest to 75 V contraction and from 75 to 150 V contraction. The displacements shown were digitized and combined with the respective estimated force applied in the tendon to calculate the tendon force-elongation relation [54].

(6)

gastrocnemius tendons. The tendon Young’s modulus and mechanical hysteresis values obtained were ~1.2 GPa and 18%, respectively [36,54–56]. Notwithstanding the good agreement of these estimates with in vitro tendon exper- imental results, the in vivo experiments failed to show the tendon linear region. Instead, the tendon tensile response was curvilinear over the loads examined. This finding indicates that isometric contractions of the tibialis ante- rior and gastrocnemius tendons generate tendon loads within the toe region, and are therefore unlikely to tear the tendon in a single pull. Further tensile measurements with reference landmarks chosen along the aponeurotic part of the tibialis anterior tendon showed that A) the entire aponeurosis strains almost 3 times as much as the tendon and B) the aponeurosis’s strain is not homoge- neous along its entire length [55,57]. Moreover, morpho- metric analysis of scans taken in the axial plane of the muscle showed that contraction increases the resting- state aponeurosis’s width and entire area [63]. These in vivo findings are in line with in situ–based reports [52,53,64].

The general consistency between the above in vivo findings and in situ-based results, as well as results from measurements on in vitro material subjected to tensile loads much smaller than that required to cause failure, adds credibility to the in vivo method. However, further studies are required to eliminate potential measurement errors. Although anatomical measurements on cadaveric muscle-tendon units have indicated that ultrasonography accurately locates connective tissue at rest [65,66], systematic research is needed to assess the accuracy of ultrasound-based measurements of connective tissue dimensions during movement upon muscle contraction and subsequent relaxation. Clearly, however, future research with respect to in vivo protocols should also be focused on quantifying the errors made in the measure- ment/calculation of tendon load.

Functional Consequences of the Mechanical Behavior of Tendons

The elasticity exhibited by a tendon on application of a tensile load has several important implications for the function of the in-series muscle.

First, having a muscle attached to a compliant tendon makes it more difficult to control the position of the joint spanned by the tendon [67]. Consider, for example, an external oscillating force applied to a joint at a certain angle. Trying to maintain the joint still would require generating a constant contractile force in the muscle.

If the tendon of the muscle is very compliant, its length will change by the external oscillating load, even if the muscle is held at a constant length. This will result in failure to maintain the joint at the angle desired.

Second, the elongation of a tendon during a static muscle contraction is accompanied by an equivalent shortening in the muscle. For a given contractile force, a more extensible tendon will allow greater shortening of the muscle. This extra shortening induces shortening in the sarcomeres of the muscle. According to the cross- bridge mechanism of contraction [68], the result of this sarcomeric shortening on the contractile force elicited would depend on the region over which the average sar- comere of the muscle operates. If the sarcomeres operate in the ascending limb of the force-length relation, a more extensible tendon will result in less contractile force. In contrast, if the sarcomeres operate in the descending limb of the force-length relation, having a more extensible tendon will result in greater contractile force [51,69].

Third, stretching a tendon results in elastic energy storage. Since tendons exhibit low mechanical hysteresis, most of the elastic energy stored during stretching is returned once the tensile load is removed. This passive mechanism of energy provision operates in tendons in the feet of legged mammals during terrestrial locomo- tion, thus saving metabolic energy that would otherwise be needed to displace the body ahead [36,70,71].

The interplay between the mechanical properties of tendons and muscle function necessitates full apprecia- tion of the mechanical properties of a healthy tendon when aiming at restoring normal muscle function and joint performance. Consider, for example, surgical proce- dures involving limb and muscle-tendon lengthening.

Any change in the resting-state length of the tendon without taking into account that this will change the extensibility of the tendon itself will clearly affect the function of the in-series muscle. Therefore, protocols for the assessment of the mechanical properties of tendons in vivo could provide crucial help for optimizing the outcome of a corrective surgery. For example, they could be used for measurements in the tendon of the con- tralateral healthy limb of the patient, thus providing reference values that could then be used for guiding the decision making.

References

1. Alexander RMcN. (1966) Rubber-like properties of the inner hinge-ligament of Pectinidae. J Exp Biol. 44:119–130.

2. Shadwick RE. (1992) Soft composites. In Vincent JFV, ed.

Biomechanics-Materials: A Practical Approach. New York:

Oxford University Press; 133–164.

3. Ettema GJ, Goh JT, Forwood MR. (1998) A new method to measure elastic properties of plastic-viscoelastic connective tissue. Med Eng Phys. 20:308–314.

4. Viidik A. (1973) Functional properties of collagenous tissues. Int Rev Connect Tissue Res. 6:127–215.

5. Butler DL, Goods ES, Noyes FR, Zerniche RF. (1978) Biomechanics of ligaments and tendons. Exerc Sports Sci Rev. 6:125–181.

(7)

6. Ker RF. (1992) Tensile fibres: strings and straps. In Vincent JFV, ed. Biomechanics-Materials: A Practical Approach.

New York: Oxford University Press; 75–97.

7. Cumming WG, Alexander RMcN, Jayes AS. (1978) Re- bound resilience of tendons in the feet of sheep. J Exp Biol.

74:75–81.

8. Ker RF. (1981) Dynamic tensile properties of the plantaris tendon of sheep (Ovies aries). J Exp Biol. 93:283–302.

9. Woo SL-Y, Ritter MA, Amiel D, Sanders TM, Gomez MA, Kuei SC, Garfin SR, Akeson WH. (1980) The biomechani- cal and biochemical properties of swine tendons—long term effects of exercise on the digital extensors. Connect Tissue Res. 7:177–183.

10. Woo SL-Y, Gomez MA, Woo Y-K, Akeson WH. (1982) Mechanical properties of tendons and ligaments II. the rela- tionships of immobilization and exercise on tissue remod- elling. Biorheology. 19:397–408.

11. Bennett MB, Ker RF, Dimery NJ, Alexander RMcN. (1986) Mechanical properties of various mammalian tendons. J Zool Lond (A). 209:537–548.

12. Shadwick RE. (1990) Elastic energy storage in tendons:

mechanical differences related to function and age. J Appl Physiol. 68:1033–1040.

13. Johnson GA, Tramaglini DM, Levine RE, Ohno K, Choi NY, Woo SL-Y. (1994) The tensile and viscoelastic proper- ties of human patellar tendon. J Orthop Res. 12:96–803.

14. Itoi E, Berglund LJ, Grabowski JJ, Schultz FM, Growney ES, Morrey BF, An KN. (1995) Tensile properties of the supraspinatus tendon. J Orthop Res. 13:578–584.

15. Rigby BJ, Hirai N, Spikes JD, Erying H. (1959) The mechan- ical properties of rat tail tendon. J Gen Physiol. 43:265–283.

16. Partington FR, Wood GC. (1963) The role of noncollagen components in the mechanical behaviour of tendon fibres.

Biochem Biophys Acta. 69:485–495.

17. Elliott DH. (1965) Structure and function of mammalian tendon. Biol Rev. 40:392–41.

18. Diamant J, Keller A, Baer E, Litt M, Arridge RGC. (1972) Collagen: ultrastructure and its relations to mechanical properties as a function of ageing. Proc Roy Soc London.

(B) 180:293–315.

19. Pollock CM, Shadwick RE. (1994) Relationship between body mass and biomechanical properties of limb tendons in adult mammals. Am J Physiol. 266:R1016-R1021.

20. Cohen RE, Hooley CJ, McCrum NG. (1976) Viscoelastic creep of collagenous tissue. J Biomech. 9:175–184.

21. Hooley CJ, McCrum, NG, Cohen RE. (1980) The viscoelas- tic deformation of tendon. J Biomech. 13:521–528.

22. Fung YCB. (1967) Elasticity of soft tissues in simple elon- gation. Am J Physiol. 213:1532–1544.

23. Riemersma DJ, Schamhardt HC. (1982) The Cryo Jaw, a clamp designed for in vivo rheology studies of horse digital flexor tendons. J Biomech. 15:619–620.

24. Woo SL-Y, Akeson WH, Jemmott GF. (1976) Measure- ments of nonhomogeneous, directional mechanical proper- ties of articular cartilage in tension. J Biomech. 9:785–791.

25. Loren GJ, Lieber RL. (1995) Tendon biomechanical prop- erties enhance human wrist muscle specialization. J Biomech. 28:791–799.

26. Matthews LS, Ellis D. (1968) Viscoelastic properties of cat tendon: Effects of time after death and preservation by freezing. J Biomech. 1:65–71.

27. Smith CW, Young IS, Kearney JN. (1996) Mechanical prop- erties of tendons: Changes with sterilization and preserva- tion. J Biomech Eng. 118:56–61.

28. Haut TL, Haut RC. (1997) The state of tissue hydration determines the strain-rate-sensitive stiffness of human patellar tendon. J Biomech. 30:79–81.

29. Savolainen J, Myllyla V, Myllyla R, Vihko V, Vaanannen K, Takala TE. (1988) Effects of denervation and immobiliza- tion on collagen synthesis in rat skeletal muscle and tendon.

Am J Physiol. 254:R897-R902.

30. Loitz BJ, Zernicke RF, Vailas AC, Kody MH, Meals RA.

(1989) Effects of short-term immobilization versus contin- uous passive motion on the biomechanical and biochemical properties of rat tendon. Clin Orthop. 224:265–271.

31. Vailas AC, Deluna DM, Lewis LL, Curwin SL, Roy RR, Alford EK. (1988) Adaptation of bone and tendon to pro- longed hindlimb suspension in rats. J Appl Physiol. 65:

373–376.

32. Viidik A. (1982) Age-related changes in connective tissues.

In: Viidik A. Lectures on Gerontology. London: Academic;

173–211.

33. Barnard K, Light ND, Sims TJ, Bailey AJ. (1987) Chemistry of the collagen cross-links. Origin and partial characteriza- tion of a putative mature cross-link of collagen. Biomech J.

244:303–309.

34. Tipton CM, Vailas AC, Matthes RD. (1986) Experimental studies on the influence of physical activity on ligaments, tendons and joints: a brief review. Acta Med Scand.

(Suppl)71:157–168.

35. Blanton PL, Biggs NL. (1970) Ultimate tensile strength of fetal and adult human tendons. J Biomech. 3:181–189.

36. Maganaris CN, Paul JP. (2002) Tensile properties of the in vivo human gastrocnemius tendon. J Biomech. 35:

1639–1646.

37. Vogel HG. (1980) Influence of maturation and ageing on mechanical and biochemical properties of connective tissue in rats. Mech Ageing Dev. 14:283–292.

38. Vogel HG. (1983) Age dependence of mechanical proper- ties of rat tail tendons (hysteresis experiments). Aktuelle Gerontol. 13:22–27.

39. Blevins FT, Hecker AT, Bigler GT, Boland AL, Hayes WC.

(1994) The effects of donor age and strain rate on the bio- mechanical properties of bone–patellar tendon–bone allo- grafts. Am J Sports Med. 22:328–333.

40. Hubbard RP, Soutas-Little RW. (1984) Mechanical proper- ties of human tendon and their age dependence. J Biomech Eng. 106:144–150.

41. Nakagawa Y, Hayashi K, Yamamoto N, Nagashima K.

(1996) Age-related changes in biomechanical properties of the Achilles tendon in rabbits. Eur J Appl Physiol. 73:7–10.

42. Phelps D, Sonstegard DA, Matthews LS. (1974) Corticos- teroid injection effects on the biomechanical properties of rabbit patellar tendons. Clin Orthop Rel Res. 100:345–348.

43. Wood TO, Cooke PH, Goodship AE. (1988) The effect of anabolic steroids on the mechanical properties and crimp morphology of the rat tendon. Am J Sports Med. 16:

153–158.

44. Noyes FR, Grood ES, Nussbaum NS, Cooper SM. (1977) Effect of intraarticular corticosteroids on ligament proper- ties. a biomechanical and histological study in rhesus knees.

Clin Orthop Rel Res. 123:197–209.

(8)

45. Herrick R, Herrick S. (1987) Ruptured triceps in a power lifter presenting a cubital tunnel syndrome: a case report.

Am J Sports Med. 15:515–516.

46. Ker RF, Alexander RMcN, Bennett MB. (1988) Why are mammalian tendons so thick? J Zool Lond. 216:309–324.

47. Witzmann FA, Kim DH, Fitts RH. (1983) Effect of hindlimb immobilization on the fatigability of skeletal muscle. J Appl Physiol. 54:1242–1248.

48. Powell PL, Roy RR, Kanim P, Bello MA, Edgerton VR.

(1984) Predictability of skeletal muscle tension from archi- tectural determinations in guinea pig hindlimbs. J Appl Physiol. 57:1715–1721.

49. Bottinelli R, Canepari M, Pellegrino MA, Reggiani C.

(1996) Force-velocity properties of human skeletal muscle fibres: myosin heavy chain and temperature dependence. J Physiol. 495:573–586.

50. Lieber RL, Leonard ME, Brown CC,Trestik CL. (1991) Frog semitendinosus tendon load-strain and stress-strain pro- perties during passive loading. Am J Physiol. 30:C86-C92.

51. Trestik CL, Lieber RL. (1993) Relationship between Achilles tendon mechanical properties and gastrocnemius muscle function. J Biomech Eng. 115:225–230.

52. Zuurbier CJ, Everard AJ, van der Wees P, Huijing PA.

(1994) Length-force characteristics of the aponeurosis in the passive and active muscle condition and in the isolated condition. J Biomech. 27:445–453.

53. Scott SH, Loeb GE. (1995) Mechanical properties of aponeurosis and tendon of the cat soleus muscle during whole-muscle isometric contractions. J Morphol. 224:73–86.

54. Maganaris CN, Paul JP. (1999) In vivo human tendon mechanical properties. J Physiol. 521:307–313.

55. Maganaris CN, Paul JP. (2000a) Load-elongation character- istics of in vivo human tendon and aponeurosis. J Exp Biol.

203:751–756.

56. Maganaris CN, Paul JP. (2000c) Hysteresis measurements in intact human tendon. J Biomech. 33:1723–1727.

57. Maganaris CN, Paul JP. (2000b) In vivo human tendinous tissue stretch upon maximal muscle force generation. J Biomech. 33:1453–1459.

58. Ito M, Kawakami Y, Ichinose Y, Fukashiro S, Fukunaga T.

(1998) Nonisometric behaviour of fascicles during isomet- ric contractions of a human muscle. J Appl Physiol. 85:

1230–1235.

59. Kubo K, Kanehisa H, Kawakami Y, Fukanaga T. (2001) Growth changes in the elastic properties of human tendon structures. Int J Sports Med. 22:138–143.

60. Kubo K, Kanehisa H, Kawakami Y, Fukunaga T. (2001) Influence of static stretching on viscoelastic properties of human tendon structures in vivo. J Appl Physiol. 90:

520–527.

61. Magnusson SP, Aagaard P, Rosager S, Dyhre-Poulen P, Kjaer M. (2001) Load displacement properties of the human triceps surae aponeurosis in vivo. J Physiol. 531:

277–288.

62. Muramatsu T, Muraoka T, Takeshita D, Kawakami Y, Hirano Y, Fukunaga T. (2001) Mechanical properties of tendon and aponeurosis of human gastrocnemius muscle in vivo. J Appl Physiol. 90:1671–1678.

63. Maganaris CN, Kawakami Y, Fukunaga T. (2001) Changes in aponeurotic dimensions upon muscle shortening: In vivo observations in man. J Anat. 199:449–456.

64. van Donkelaar CC, Willems PJB, Muijtjens AMM, Drost MR. (1999) Skeletal muscle transverse strain during iso- metric contraction at different lengths. J Biomech. 32:

755–762.

65. Kawakami Y, Abe T, Fukunaga T. (1993) Muscle-fiber pen- nation angles are greater in hypertrophied than in normal muscles. J Appl Physiol. 74:2740–2744.

66. Narici MV, Binzoni T, Hiltbrand E, Fasel J, Terrier F, Cerretelli P. (1996) In vivo human gastrocnemius architec- ture with changing joint angle at rest and during graded iso- metric contraction. J Physiol. 496:287–297.

67. Rack PMH, Ross HF. (1984) The tendon of flexor pollicis longus: its effects on the muscular control of force and posi- tion at the human thumb. J Physiol. 351:99–110.

68. Huxley AF. (1957) Muscle structure and theories of contraction. Prog Biophys Chem. 7:255–318.

69. Zajac FE. (1989) Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.

CRC Crit Rev Biomed Eng. 17:359–411.

70. Cavagna GA. (1977) Storage and utilization of elastic energy in skeletal muscle. Exerc Sports Sci Rev. 5:89–129.

71. Alexander RMcN. (1988) Elastic Mechanisms in Animal Movement. Cambridge, England: Cambridge University Press.

Riferimenti

Documenti correlati

(B) The quantitative analysis of SDH activity indicates differences depending on fiber type and age (a, significantly different from age matched type-IIB fibers, p < 0.001;

Sections 4 and 5 contain a blow-up analysis (at the right and at the left junction respectively) leading to some uniform bounds of the frequency function which allow describing,

A deep insight into [17] highlights how the dependence on the subsequences in Theorem 1.1 is a priori given by two different facts: on one hand, the convergence to the limit profile

Post-experimental analy- ses highlight that thermal microcracking, a result of the highly anisotropic thermal expansion of calcite, exerts a greater influence on rock

(A) First hypothesis considers a diploid genome with two sex chromosome pairs, namely I and I ’ and L and L’, bearing ZsMATa cassettes 1, 2, and 3, and ZsMATa cassette, which are

For many years, patellofemoral malalignment (PFM), an abnormality of patellar tracking that involves lateral displacement or lateral tilt of the patella (or both) in extension

Although both its mechanisms of action and clinical effects are subjects of controversy, electrical stimulation at various sites in the central nervous system has been shown to

Radiation therapy plays an increasingly important role in the treatment of benign tumors of the anterior afferent visual pathway, due primarily to the evolution of