• Non ci sono risultati.

Oxide mem- branes fabricated on a standard CMOS process have experimentally confirmed the validity of the method

N/A
N/A
Protected

Academic year: 2021

Condividi "Oxide mem- branes fabricated on a standard CMOS process have experimentally confirmed the validity of the method"

Copied!
2
0
0

Testo completo

(1)

Conclusions

The research activity of my Ph.D. was focused on CMOS-compatible MEMS processes and their application to the development of biosensors.

A technique to reduce the etching times and increase the freedom in the de- sign of large suspended microstructures fabricated by bulk anisotropic etching of silicon was demonstrated. The anisotropic etching properties of tetramethy- lammonium hydroxide (TMAH)-based solutions were exploited to obtain this result. The design of periodic convex-corner patterns with which to pre-pattern the membrane was exploited to radically reduce the release times. Oxide mem- branes fabricated on a standard CMOS process have experimentally confirmed the validity of the method. Furthermore, the etch parameters of TMAH-based solutions were extracted from the observed etch evolution, and were user to develop a mathematical model which is able to predict, with good agreement, the structure release times.

The design and fabrication technology of a magnetically actuated MEMS microbalance for biosensing application was improved. The sensors are fabri- cated with a MEMS (Micro-electro-mechanical System) post-processing method applied on a standard, CMOS-based VLSI technology, retaining maximum com- patibility with the CMOS process flow. The mechanical resonator is based on inductive actuation and detection, and the sensing is based on the microbal- ance principle. A CMOS-compatible process for silanization, funtionalization and hybridization of the MEMS microbalance surface was developed. A com- plete electro-mechanical characterization of the fabricated MEMS resonators

63

(2)

Conclusions

was carried out, and the functionality of the gravimetic transduction was veri- fied.

A single chip integrated electronic oscillator was designed, in which the proposed resonator was used as the frequency-selective feedback network. The proposed MEMS resonator was used as filtering element. Electrical simulations have been extensively used during the design phase of the circuit. Presented simulation results led to the implementation of a first prototype of the designed circuit. The frequency spectrum and frequency/temperature characteristics of the implemented circuit were measured.

Possible further developments are constituted by the design of a fully inte- grated version of the oscillator circuit and of a specific fluidic package for the biosensor. Moreover, the development of a selective functionalization process will allow the fabrication of a sensors array.

64

Riferimenti

Documenti correlati

Comparison of the relevant X-ray diffraction signals marking the state of the thick filament demonstrates that the force feedback that controls the regulatory state of the

ordine pubblico e sicurezza di competenza statale così come i rapporti con le confessioni religiose), sia su più sfumati principî europei e internazionali in materia di

Reprinted, with permission, from Russino, Pieri, Nan- nini, "Mass response of a CMOS-compatible, magnetically actuated MEMS microbalance," Sensors and Microsystems,

A first activity has been oriented towards the development of a technique to reduce the etching times and increase the freedom in the design of large sus- pended

During the transfer of data to the tax authorities on the availability of real property subject to taxation from physical persons, identification of addresses of buildings in

Magnetic resonance imaging is widely used for in vivo applications, due to its safety, spatial resolution, soft tissue contrast, clinical relevance, and ability to record anatomical

In some pathological circumstances, when the financial intermediary acquires a relevant information monopoly due to the close customer relationship, a firm might be locked-in,

In questo studio, dei vari fattori di rischio legati al ricevente e al donatore, tra i quali il sesso l’età, la diagnosi pre trapianto, il tempo di ischemia fredda,