• Non ci sono risultati.

Camera televisiva a scansione lenta per misure spettroscopiche

N/A
N/A
Protected

Academic year: 2022

Condividi "Camera televisiva a scansione lenta per misure spettroscopiche"

Copied!
8
0
0

Testo completo

(1)

ETH Library

Camera televisiva a scansione lenta per misure spettroscopiche

Doctoral Thesis Author(s):

Donati, Marco Publication date:

1974

Permanent link:

https://doi.org/10.3929/ethz-a-000085314 Rights / license:

In Copyright - Non-Commercial Use Permitted

This page was generated automatically upon download from the ETH Zurich Research Collection.

For more information, please consult the Terms of use.

(2)

Diss. ETH 5254

CAMERA TELEVISIVA A SCANSIONE LENTA PER MISURE SPETTROSCOPICHE

DISSERTAZIONE

per il conseguimento del titolo di dottore in scienze tecniche

della

SCUOLA POLITECNICA FEDERALE ZURIGO

presentata da MARCO DONATI

ing. el. dipi. SPFZ

nato

il 20 dicembre 1945

di Broglio (Ct. Ticino)

Accettata

su

proposta di Prof. Dr. M.

J.

O. Strutt, relatore

Prof. Dr. U. P. Wild, correlatore

aku-Fotodruck Zùrich

1974

(3)

_ 122 _

Riassunto

Si è costruito una camera televisiva il cui tubo analizzatore di

tipo

vidicon è adatto a scansioni lente.

L'elemento centrale di controllo del processo di misura e dell'elaborazione dei dati è il

minicomputer PDP8/I

con relati¬

va interface

(29).

L'esplorazione d'immagine

è

digitale

così da compensare la di¬

minuzione del

segnale

dovuta al

tempo

d'analisi elevato.

Di ogni

quadro

si analizzano 256 x

256

elementi

(100

us per

punto),

con

512

x

512 punti

si deve contare su una

perdita

nel

potere

risolutivo. La caratteristica di

Storage

del TD

131-5-018 permette l'integrazione

di

segnali

deboli

(naturalmente

nel caso di immagini

statiche)

per ca. 15

minuti; 1'mtegrazaone

per

tempi

maggiori va a

scapito

del potere risolutivo per l'evidenziarsi della corrente d'oscurità

(lateral leakage).

L'accoppiamento

con un convertitore

d'immagine (RCA 44-49A)

permette la registrazione di spettri di assorbimento o emissio¬

ne m

tempi

successivi l'eccitazione luminosa di una

sostanza;

le immagini che appaiono sullo schermo fosforescente dell'I.C.

vengono

integrate

ed immagazzinate sullo strato fotosensibile del vidicon restando

così

a

disposizione

per l'analisi elet¬

tronica. Il

tempo d'apertura

minimo della

griglia

dell'I.C.

che permette ancora la

registrazione

di

un'immagine

con il vidicon è di ca. 20 us; ciò grazie alla persistenza del fosfo¬

ro Pll dell'I.C. e con illuminazioni notevoli.

(4)

-

123

-

Per

tempi

minori

(

e non considerando l'inerzia del foto¬

conduttore)

è necessario l'uso di un tubo

più

sensibile

(per

es. un SEC-Intensifier come il WL

32000, Westinghouse).

I

segnali

di linee d'analisi diverse

(di

tutta

l'immagine

e di

immagini

successive usando nastri

magnetici)

vengono

immagazzinati

nella memoria del

PDP8/I

per la successiva elaborazione.

(5)

- 124 -

Zusa^ienfassung

Eme Fernsehkamera mit emer Vidicon-Eohre fur

langsame Abtastungen

uurde

gebaut.

Zentralelement des

Ilessprozesses

und der

Ddtenverarbeitung

ist der

Klemcomputer PDP8/I

und das

entsprechende

Interface

(IF

1 - PC

ETH).

Eme

digitale Bildabtastung

vermeidet die

Signalverklemerung

welche die grosse Bildabtastzeit verursachen Viurde.

Von

jedem

Bild verden

256

x

256

Punkte

abgetastet (100

us prò

Punkt),

bei 512 x

512

Punkten muss mit emer Auf

losungsverkleme-

rung

gerechnet

werden.

Die

Speichereigenschaft

des TD 1343-018 erlaubt die Integrataci schwacher

Signale (nur

ìm Falle statischer

Bilder)

wahrend etua

15 Mmuten, langere Integrations^eiten

verursachen emen Verlust des

Auflosungsvermogens mfolge Dunkelstrombildung.

Die

Verbmdung

des Vidicons mit dem

Image

Converter RCA

4449A

erlaubt die Aufnahme von

Absorptuons-oder -Emissionspektren

in emstellbaren Zeiten nach der

Lichterregung

emer Substanz.

Die am Anodenschirm des I.C. erschemenden Bilder werden von der

Vidicon-photoschicht mtegriert

und

gespeichert.

Die sukzessive

langsame Abtastung

liest die

gespeicherte

Information. Dank der Persistenz des

Phosphors

Pll des Anoden- schirmes der I.C. ist es

moglich

Vidicon-Aufnahmen bis zu

etwa 20 us I.C.-Verschlusszeit zu realisieren.

Dazu smd

jedoch

grosse Lichtmtensitaten erforderlich.

(6)

-

125

-

Fur klemere Zexten

(und

ohne

Betrachtung

der Photoschicht-

tragheit)

muss exne

empfindlichere

Rohre verwendet werden

(z.B.

SEC-Intensifier WL 32000 von

Westxnghouse).

Signale

von verschiedenen Abtastzeilen

(vom

ganzen Bild und von sukzessiven Bxlder falls

magnetische

Bandei

gebraucht

werden)

werden ìm

Computer-memory

fur die

Datenverarbeitung

gespeichert.

(7)

- 126 -

Abstract

In this work a television camera was built with a slow scan vidicon tube.

The main eleraent of the

measuring system

and of the data

processing

used in this work was the small

computer PDP8/I

and the

corresponding

interface

(IF

1 - PC

ETH).

A

digitai picture scanning

was used which

helps

to avoid

a reduction in

signal amplitude

which would have been caused

by

a

long

frame time.

256 x

256

elements are scanned from each

image (100

us for each

element).

The

scanning

of

512

x 512 elements would cause a reduction in signal

amplitude.

The

Storage

characteristics of the tube TD 13^5-018 allow the

integration

of weak

signals during approximately

15 min.

(static images).

Longer integration

times cause a consideratale decline of the resolution

capability.

This is

mainly

due to the influence of the dark current.

The combination of the vidicon tube with an

image

converter tube

(RCA 4-449A)

allows the

recording

of emission and

absorption spectra

of

light

excited substances with

programmed

exposure times and intervals.

At the anode of the

image

converter appears an

image

which is

integrated

and stored

by

the vidicon

photolayer.

Then a successive slow

scanning

records the stored information.

(8)

-

127

-

The

good persistence

of the Pll

phosphor

of the anode of the

image

converter tube allows

recording

with the vidicon camera up to about 20 us exposure times.

However,

the

light

intensities involved must be

high enough

to allow such a

recording.

For shorter exposure times a more sensitive tube must be

used,

for

example

SEC-Intensifier WL 32000

(Westinghouse).

The inertia characteristics of the

photosensitive layer

must be taken into consìderation.

Signals originating

from the

scanning

of different lines of an

image (or

of successive

images

in case of

magnetic

DEC-tapes)

are stored in the

computer

memory for further data

processing.

Riferimenti

Documenti correlati

This changed at the seventh meeting in Toledo, Spain, in 1994, which took place shortly after the so-called REAL classification (“revised European-American lymphoma

This result strongly suggests that we are observing discrete shifts from part-time to full-time work, as conjectured by Zabalza et al 1980 and Baker and Benjamin 1999, rather

In particular, generational accounting tries to determine the present value of the primary surplus that the future generation must pay to government in order to satisfy the

The success of such a complex project rests on challenging scientific and technical developments, four of which could benefit from Italian know-how and innovative approach: (1)

Keywords: chitosan; physico-chemical properties; molecular weight; degree of acetylation; conformation; antimicrobial activity; from gel to nanobeads; drug

And, he goes on, if someone moves «while fixing his sight upon the icon», he «will find that the icon's look proceeds continually with him», and «marvel that it moves keeping

The Perceptual Form of the City In late 1953, György Kepes and Kevin Lynch, the first lecturing in Visual De- sign and the other in City Planning, put forward a project for

Here, to make up for the relative sparseness of weather and hydrological data, or malfunctioning at the highest altitudes, we complemented ground data using series of remote sensing