Measurement of sound absorption Measurement of sound absorption
coefficient coefficient
Angelo Farina
Dip. di Ingegneria Industriale - Università di Parma Parco Area delle Scienze 181/A, 43100 Parma – Italy
angelo.farina@unipr.it
With regard to apparent acoustic absorption, IT DOES NOT MATTER
That the energy is really absorbed, or just transmitted
INTERESSA SOLO SAPERE QUANTA ENERGIA
Measurmeent Methods
•Reverberant room (ISO 354)
• Standing Wave Tube (pressure measurements, ISO 10534)
• Impulsive Method (EN 1793/5)
• Sound Intensity Method (in tube or in free field)
According to ISO 354
The reverberation time is measured twice, the first time with the room empty (Te), the second after introducing a sample surface S of
approximately 10 m2 of absorbing material (Ts). Of course Ts is smaller than Te.
Te
Ts
10 mq
S A
T V A
T V
e s
e
e
16 , 0 16
, 0
: apparent sound absorption coefficient of sample V : Volume of the reverberant room
S : Surface of the sample
T
e: Reverberation Time of the empty room
T
S: Reverberation Time of the room fitted with sample
Measuring in reverberant room
According to ISO 354
e
s
T
T S
V 1 1 16
,
0
Measuring in reverberant room According to ISO 354
: apparent sound absorption coefficient of sample V : Volume of the reverberant room
S : Surface of the sample
T
e: Reverberation Time of the empty room
T
S: Reverberation Time of the room fitted with sample
Attention: The ISO 354 method easily results in values of exceeding 1.00, up to 1.20 !!!
Measuring in reverberant room according to ISO 354
Pros:
• Very precise and accurate laboratory method
• The results can be directly employed in Sabine’s formula for estimating the performances of the absorbing material in a real room
Cons:
• The measured value is NOT the physically-correct absorption coefficient, as its value can be much larger than 1 – this is Sabine, not the “true”
• An expensive laboratory facility is required
• A large surface of the material to be tested is required
Measuring in reverberant room
According to ISO 354
Measuring in a Standing Wave Apparatus
According to ISO 10534
Measuring in a Standing Wave Apparatus
According to ISO 10534
2 2
min max
min max
min max
p p p
p p p
p p
p
p p
p
rif inc rif
inc
rif inc
2
min max
min max
2 2
1 1
1
1
p p
p p
p p I
r I
inc rif inc
rifMeasuring in a Standing Wave Apparatus
According to ISO 10534
Pros:
• Very precise and accurate laboratory method
• The measured value is always bound between 0 and 1 (“true” ) Cons:
• Very slow, one measurement at every frequency
• An expert operator is required, every measurement requires accurate
manual positioning of the microphone for locating accurately the position of max and min pressure
• The method is not easily automated
Measuring in a Standing Wave Apparatus
According to ISO 10534
Measuring with the impulsive method EN 1793-5
The test signal (MLS or Sweep) is generated by a loudspeaker in front of the
surface to be measured, and a microphone is placed in front of it. The system can be tilted, so that different incidence angles can be measured
Direct Sound Subraction
First the loudspeaker/microphone assembly is rotated toward sky, and a free field response is measured. Then the system is rotated towards the barrier, and its response is measured. Finally, the free field response is subrtacted by
Free Field
Barrier response
Misura di con metodo impulsivo EN 1793-5
MP
Misura di con metodo impulsivo EN 1793-5
La finestra Adrienne viene posizionata sul suono diretto e su quello riflesso Campo Diretto
Campo Riflesso
Misura di con metodo impulsivo EN 1793-5
Viene poi calcolato lo spettro FFT, con
ponderazione temporale crescente, del segnale diretto e riflesso.
Indi si fa il rapporto fra i due spettri, mediato per bande di 1/3 d’ottava.
Tale rapporto fornisce il coeff. di riflessione r.
Campo Diretto
Campo Riflesso
Compensazione divergenza geometrica
Il segnale riflesso ha percorso un tragitto piu’ lungo, e’ come se provenisse da una sorgente-immagine piu’ lontana. Quindi e’ piu’ debole.
Si compensa tale attenuazione per divergenza geometrica moltiplicando l’ampiezza del segnale per il “tempo di volo” corrente, misurato dall’istante
Compensazione divergenza geometrica
Pessimo accordo con i valori di laboratorio, sistematica sottostima dell’effettivo assorbimento
Valutazione come attenuazione in dB(A)
Le norme EN 1731 prevedono la valutazione complessiva della “perdita per riflessione” DLRI della barriera antirumore, valutando l’attenuazione in
dB(A) del suono riflesso, utilizzando uno “spettro normalizzato” del rumore da traffico stradale
Valutazione come attenuazione in dB(A)
Stessa analisi puo’essere condotta anche sui risultati delle misure in camera riverberante secondo ISO 354, che fornisce un corrispondente valore di DL Questi sono i risultati del raffronto fra i valori misurati su una barriera in legno e su una barriera metallica:
Si nota che i valori misurato in opera sono circa ¼ di quelli di laboratorio…
Metodo intensimetrico
La sonda non misura separatamente I
inced I
rif, misura invece la intensita’ totale risultante, che vale ovviamente I
tot= I
inc- I
rifIrif Iinc
Metodo intensimetrico
La sonda misura anche la pressione sonora (SP) e la velocita’
delle particelle (PV, particle velocity), da cui si calcola la densita’ di energia sonora ED (Energy Density)
2 22c PV SP
2 ED 1
Ovviamente la densita’ sonora puo’ anche essere espressa come somma delle intensita’ incidente e riflessa, per cui abbiamo:
2 2
rif tot inc tot
rif inc
tot
rif inc
I c I ED
I c I ED
I I
I
I I
c
ED
Metodo intensimetrico
Da cui si ricava facilmente il coeff. di riflessione ed .
Poiche’ I
tote’ sempre positivo, ma <= di ED·c, il valore di misurato e’ sempre compreso fra 0 e 1
r c
ED I c ED
I I
c ED
I c
r ED
tot tot
tot
tot