CONTRIBUTION DESCRIPTION FF_PANTEGANA

ƒ General Description:

Designer Name: Enrico Oberti

GDSII File Name:

FF_ PANTEGANA.gds

Category:

New Structure Development Cell

Content Summary:

Single PMOS devices test chip for noise characterization.

Main Specifications: List of integrated devices (W/L):

10/0.13 20/0.13 100/0.13 200/0.13 600/0.13 1000/0.13

20/0.20 200/0.20 1000/0.20

10/0.35 20/0.35 100/0.35 200/0.35 600/0.35 1000/0.35

20/0.50 200/0.50 1000/0.50

20/0.70 200/0.70 1000/0.70

20/1.00 200/1.00 1000/1.00

10/10

Aim of the Contribution: First validation

(2)

ƒ Pad Frame

External pad ring ST Logo

Internal pad line #1

Internal pad line #2

Internal pad line #3

Internal pad line #4

(3)

ƒ Pin List

External pad ring

Drain_10_013 10/0.13 W/L device drain Gate_10_013 10/0.13 W/L device gate Drain_10_035 10/0.35 W/L device drain Gate_10_035 10/0.13 W/L device gate Drain_20_013 20/0.13 W/L device drain Gate_20_013 20/0.13 W/L device gate Drain_20_02 20/0.20 W/L device drain Gate_20_02 20/0.20 W/L device gate Drain_20_035 20/0.35 W/L device drain Gate_20_035 20/0.35 W/L device gate (Unused)

Vplus VDD pad protection diodes pin Well Nwell

Bulk Substrate and GND pad protection diodes pin (Unused)

Source_1000 W=1000 um devices source

Source_200_600 W=200 um and W=600 um devices source Source_100_200 W=100 um and W=200 um devices source Source_20_100 W=20 um and W=100 um devices source Source_10_20 W=10 um and W=20 um devices source

Internal pad line #1

Drain_20_05 20/0.50 W/L device drain Gate_20_05 20/0.50 W/L device gate Drain_20_07 20/0.70 W/L device drain Gate_20_07 20/0.70 W/L device gate Drain_20_1 20/1.00 W/L device drain Gate_20_1 20/1.00 W/L device gate Drain_100_013 100/0.13 W/L device drain Gate_100_013 100/0.13 W/L device gate Drain_100_035 100/0.35 W/L device drain Gate_100_035 100/0.35 W/L device gate

Internal pad line #2

Drain_200_013 200/0.13 W/L device drain Gate_200_013 200/0.13 W/L device gate Drain_200_02 200/0.20 W/L device drain Gate_200_02 200/0.20 W/L device gate Drain_200_035 200/0.35 W/L device drain Gate_200_0.35 200/0.35 W/L device gate Drain_200_05 200/0.50 W/L device drain Gate_200_05 200/0.50 W/L device gate Drain_200_07 200/0.70 W/L device drain Gate_200_07 200/0.70 W/L device gate

Internal pad line #3

(4)

Gate_600_013 600/0.13 W/L device gate Drain_600_035 600/0.35 W/L device drain Gate_600_0.35 600/0.35 W/L device gate Drain_1000_013 1000/0.13 W/L device drain Gate_1000_013 1000/0.13 W/L device gate Drain_1000_02 1000/0.20 W/L device drain Gate_1000_07 1000/0.20 W/L device gate

Internal pad line #4

Drain_1000_035 1000/0.35 W/L device drain Gate_1000_035 1000/0.35 W/L device gate Drain_1000_05 1000/0.50 W/L device drain Gate_1000_05 1000/0.50 W/L device gate Drain_1000_07 1000/0.70 W/L device drain Gate_1000_0.7 1000/0.70 W/L device gate Drain_1000_1 1000/1.00 W/L device drain Gate_1000_1 1000/1.00 W/L device gate Drain_10_10 10/10 W/L device drain Gate_10_10 10/10 W/L device gate

(5)

• Top Layout View

(6)

Top Block Schematic:

ƒ Specifities: None

Riferimenti

Documenti correlati

Lakatos Imre, Dimostrazioni e confutazioni – La logica della scoperta matematica, a cura di John Worrall e Elie Zahar, introduzione all’edizione italiana di Giulio Giorello,

Nel file di ingresso sono elencati per ogni oggetto i tempi UT di inizio esposizione, le coordinate equatoriali precessate alla data attuale e la stringa identificativa

Regression analyses showed that both M capacity and executive function predicted development in dog drawing; the dog drawing score correlated with M capacity and

As in previous years, one of the Commission's main concerns in the com petition policy area was its concern to strengthen and preserve small and medium-sized

Second, the case study on European policy divergence in the management of the Eurozone crisis examines whether the different positions of member governments correspond to

Dopo aver proceduto alla ristampa di numerosi volumi che erano ormai esauriti, è nostra intenzione proseguire nel pro- getto originario che si è rivelato apprezzato da numerosi

Le! dodici! barriere! appena! citate! sono! alcuni! esempi! che! possono! farci! capire! come,! dei! messaggi! rivolti! anche! a! fin! di! bene,! possono! avere! effetti!

To maintain the level of co-activation also under the progression of muscle fatigue, the muscle activation is estimated and controlled using an underlying feedback of the