(1)

Installation

accessories

(2)

INDEX

Adaptors ... 3

Replacement stickers ... 4

Faucet plastic sleeves ... 4

Digital flow meters ... 5

Mechanical flow meters ... 10

Connectors ... 11

Clip ... 13

Tube inserts ... 14

TDS regulators ... 14

H2O pressure reducers ... 15

Co2 pressure reducers ... 17

Ball valves ... 25

Diverter valves ... 27

Check valves ... 28

Water Block valves ... 28

In-let and drain valves ... 30

(3)

Adaptors

Code: 01004001

EDA External Adapter (Clamp)

Code: 01004002

External Adapter (Screw)

Code: 01004003

AD-1 Brass reduce Adaptor

(4)

Code: 01004004

Faucet adaptor for demostration

Replacement stickers

Code: 01015001

Round sticker water,Co2 inlet/outlet 20x20 mm.

Variants

Code Description

01015001-01 Round sticker 20x20 mm. " H2O IN "

01015001-02 Round sticker 20x20 mm. " Co2 IN "

01015001-03 Round sticker 20x20 mm. " OUT Naturale/Ambient "

01015001-04 Round sticker 20x20 mm. " OUT Fredda/Cold "

01015001-05 Round sticker 20x20 mm. " OUT Frizzante/Sparkling "

01015001-06 Round sticker 20x20 mm. " OUT Scarico/Drain "

01015001-07 Round sticker 20x20 mm. " OUT Ricircolo/Recirculation "

Faucet plastic sleeves

Code: 01006101

Faucet plastic sleeve 1/4"

(5)

Digital flow meters

Code: 01001202

Meter a bright LED Digiflow 5000V monitoring liters

Variants

Code Description

01001202-01 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 1.000 liters 01001202-02 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 2.000 liters 01001202-03 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 3.000 liters 01001202-04 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 4.000 liters 01001202-05 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 5.000 liters 01001202-06 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 6.000 liters 01001202-07 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 7.000 liters 01001202-08 Meter a bright LED Digiflow 5000V monitoring liters Pre-set at 8.000 liters<br />

Clear indicating of filter status

The DigiFlow 5000V incorporate an advanced microprocessor circuit and precision flow sensor to

accurately monitor filter life. The double-color LED conveniently indicates the status of filter. A built-in audio device generates an alert alarm when the filter life reaches its end. No external power needed. The

DigiFlow 5000V can be used with all kinds of under-sink water filters, including installed ones. The DigiFlow 5000V is powered by two AAA alkaline batteries which generally last for more than two years. A built-in semiconductor memory device automatically stores the last status when battery power runs out.

16 pre-set monitoring capacity options :

1000, 2000, 3000, 4000, 5000, 6000, 7000 and 8000 liters.

Remaining capacity indicating :

Green light blinks 10 times – 100% capacity remaining 9 times – 90% capacity remaining

………

1 time – 10% capacity remaining End of life alert :

Red light blinks all the times and an addible alarm is generated when the remaining capacity is 0.

An audible alarm.

(6)

Code: 01001203

Digiflow 6000R-L Flow meters LCD volume in liters (50)

Measuring flow capacity of filter

The DigiFlow 6000R is a flow totalizer with LCD display. It displays the accumulated volume flowing through. Both of the gallon and liter models are available. Accumulated volume displayed up to 99999 gallons and 99999 liters.

Monitoring up to five filter volume capacity

Besides the totalization function, the DigiFlow 6000R is programmable to monitor up to five filters in volume capacity from 100 to 9900 gallons (gallon model) or 500 to 99500 liters (liter model). The LCD of the DigiFlow 6000R blinks the filter number and generates an audible alert when the monitoring volume capacity of the specific filter reaches the end.

The DigiFlow 6000R comes with a 3/ 8” NPT female thread, which is adapted to most of the fittings to connect with filters.

No external power needed. The DigiFlow 6000R is operated by two AAA alkaline batteries which power lasts more than one year . The last status data will be automatically memorized when the battery power is off.

The DigiFlow 6000R is applied for water filters, water dispensers and coolers.

Install Batteries

Slide off the cover case of the battery room, and put into 2 AAA batteries. Then slide the cover case back.

Connecting Fitting

The specification of the DigiFlow 6000R connectors is 3/8” MNPT female. You could use any 3/8” MNPT male connectors.

Setting Filter Capacity

Keep pressing DISPLAY button, then press RESET button and release both of the buttons. The

DigiFlow 6000R will go into setting procedure. The digit will blink “FLT 1” four times, then blink “ OFF” to notice you that the setting procedure is on. Press DISPLAY button to choose the

capacity value. The sequence is OFF - 0 – 100 – 200 – 300 …… 19800 – 19900 – OFF – 0 –100 (gallon model) and OFF - 0 –500 – 1000 --- 99500 – OFF – 0 – 500 (Liter model). Then press RESET button to save the filter capacity value.

* If the setting value is “OFF”, the monitor function of the dedicated filter will be disable.

Operating

The DigiFlow 6000R will be automatically turn on when there is water flowing through the sensor. It will automatically turn off in 10 seconds when there is no water flowing. The DigiFlow 6000R display the total flowing volume.

Check Filter Remaining Capacity

Press DISPLAY button will display the remaining capacity of each filter. The DigiFlow 6000R will blink the dedicated filter twice, then blink the remaining capacity twice. For example, “FLT 1”, then“ 988 ltr”, then “ FLT 2” …….. After display all remaining capacity of each filter, the DigiFlow 6000R goes back to display the

(7)

total flowing volume.

End o Life Alert

When there is any filter remaining capacity reaches 0 gallon (liter), the buzzer will beep twice and the DigiFlow 6000R will blink the dedicated filter, for example, like “ FLT 2” to notice user that the 2nd filter cartridge is in its end of life, and out of function. In the alert status, user press

DISPLAY button is not able to check the remaining capacity of each filter, but to display the total flowing volume.

After change the dedicated filter cartridge, press RESET button. The remaining capacity of the dedicated filter cartridge be reset to the original setting value. And the alert status is released.

For example, if user set the capacity of the “FLT 1” and “FLT 2” as 500 gallons and 1000 gallons.

When the total flowing volume reaches 500 gallons, the DigiFlow 6000R will go into alert status, and blink “ FLT 1 ” when there is water flowing through. However the DigiFlow 6000R will keep calculate the total flowing volume and monitor the other filter. When user change the 1st filter cartridge and press RESET button at the total flowing volume 520 gallons. The end of life alert of the 1st filter cartridge will be at 1020 gallons (520 + 500 gallons).

Low Battery Power Alert

When the battery power lower than normal working level, the buzzer will beep twice to notice and the battery symbol on the screen will blink to notice user to change the battery. Once the batteries are

replaced, the alert will be released. The data will be kept in memory and stored back when user replace the batteries.

Code: 01001205

Digiflow 8000T Water meters LCD time/volume in liters (50)

INSTALLING BATTERY

Slide off the cover case of the battery room, and put into 2AAA batteries.Then slide the cover case back.

SETTING CAPACITY AND TIMING

Keep pressing display button, then press reset button and release both of the buttons. The DigliFlow 8000T will go into setting procedure. The digit will flash to notice you that the setting procedure is on.

SETTING CAPACITY

Press display button to choose the capacity. The sequence is 0-100-200-300...9800-9900-OFF. Then press reset button to save the capacity. Then go into Timing setting. *The capacity mode will be disabled when you choose OFF.

SET TIMING

Press Display button to choose the Timing. The sequence is 0-30-60-90...690-720-OFF. Then press reset to save the Timing. The setting procedure is completed. *The capacity mode will be disabled when you choose OFF. **The setting procedure will be terminated, and go back to the original status if there is no input for 10 seconds.

CONNECTING FITTING

(8)

OPERATING

The DigiFlow 8000T will be automatically on when there is any water flowing through the sensor. It will be automatically off wen there is no water flowing for 10 seconds.

DISPLAY BUTTON:

Press display button is to display the status of the three modes of the DigiFlow 8000T. Capacity mode:

showing the capacity left. Timing mode; showing the timing left. Flow rate mode: showing the current flow rate. The sequence is Flow-rate - Timing Capacity...

RESET BUTTON:

Press reset button is to reset the setting to be the last setting.

ALARM - Noticing Alarm

When Capacity is lower than 30 gallons or timing is lower than 7 days, the buzzer will beep once and the digit will beep once and the digit will flash to notice you to prepare changing the filter cartridge when there is any water flowing through DigiFlow 8000T or press the display button.

Warning Alarm

When Capacity reaches 0 gallon or Timing reaches 0 day, the buzzer will beep twice and the digit will flash to notice you to change the filter cartridge when there is any water flowing through Digiflow 8000T or press the display button.

Low Battery Power Alarm

When the battery power lower than normal working level, the buzzer will beep twice to notice you to change the battery. The data will be kept in memory when the battery power is run out or battery is removed.

Code: 01001208

Digiflow 8100T Water meters LCD time/volume in liters (50)

Flow meter with external turbine type Time-Metered measures water flow in liters or gallons.

* IN - OUT: 1/4" BSP male Features:

- Filter capacity life monitor (from 500 to 99500 liters);

- Filter elapse time monitor (from 30 to 720 days);

- Flow rate display (0,8 -8,0 lpm);

- Near end of filter life alert;

- End of filter life alert;

- Low battery power alert;

- Automatic data memorized when battery power is off.

Application:

- Undercounter water treatment system;

- Commercial water treatment system;

- Water dispenser.

INSTALLING BATTERY

(9)

Slide off the cover case of the battery room, and put into 2AA batteries.Then slide the cover case back.

SETTING CAPACITY AND TIMING

Keep pressing display button, then press reset button and release both of the buttons. The DigliFlow 8100T will go into setting procedure. The digit will flash to notice you that the setting procedure is on.

CONNECTING FITTING

The specification of the DigiFlow8100T connectors is 1/4" BSP male.

SETTING CAPACITY

Press display button to choose the capacity. The sequence is -500-1000...99500-OFF. Then press reset button to save the capacity. Then go into Timing setting.

SET TIMING

Press Display button to choose the Timing. The sequence is 0-30-60-90...690-720-0-30OFF. Then press reset to save the Timing. The setting procedure is completed. *The capacity mode will be disabled when you choose OFF. **The setting procedure will be terminated, and go back to the original status if there is no input for 10 seconds.

OPERATING

The DigiFlow 8100T will be automatically on when there is any water flowing through the sensor. It will be automatically off wen there is no water flowing for 10 seconds.

DISPLAY BUTTON:

Press display button is to display the status of the three modes of the DigiFlow 8100T. Capacity mode:

showing the capacity left. Timing mode; showing the timing left. Flow rate mode: showing the current flow rate. The sequence is Flow-rate - Timing Capacity...

RESET BUTTON:

Press reset button is to reset the setting to be the last setting.

ALARM - Noticing Alarm

When Capacity is lower than 100 gallons or timing is lower than 7 days, the buzzer will beep once and the digit will beep once and the digit will flash to notice you to prepare changing the filter cartridge when there is any water flowing through DigiFlow 8100T or press the display button.

Warning Alarm

When Capacity reaches 0 gallon or Timing reaches 0 day, the buzzer will beep twice and the digit will flash to notice you to change the filter cartridge when there is any water flowing through Digiflow 8100T or press the display button.

Low Battery Power Alarm

When the battery power lower than normal working level, the buzzer will beep twice to notice you to change the battery. The data will be kept in memory when the battery power is run out or battery is removed.

(10)

Mechanical flow meters

Code: 01001101

Water meter at progressive numeration (40)

Variants

Code Description

01001101-01 Water meter at progressive numeration with connectors (40) 01001101-02 Water meter at progressive numeration without connectors (40)

Water's counter at only jet super Dry with dry quadrant.

Quadrant's size: 20mm

* direct reading with 8 roller

* Inlet/Outlet connections: 3/4" male thread (it is provided with 2 junctions 1/2" male thread

* maximum flow rate: 3,125m3/h

* 360° adjustable quadrant

* classe B-H/A-V

* cold water 30°C

* hot water 90°C

* magnetic dragging

* Work's maximum pressure: 16bar

* anti-magnetic's Device on request Code: 01001102

Waterminder watermeter auto-block 1/4" (60)

Stop the flow of water to reach the capacity of the filters. Mechanical operation with the pressure of the water. The Water Minder is programmable from 1 to 6.000 liters, decreasing a notch to every liter of water past. Of easy use and conduction enough to arm the wheel situated in head to reactivate the system.

* Inlet-outlet : male threaded 1/4".

* Dimensions: 9 cm. OD x 6 cm.

(11)

Connectors

Code: 01001001

E.Z. Feed Water Connector ,with Free Degree Nut 3/4"x3/4"

Code: 01001002

E.Z. Feed Water Connector 1/4" - 1/2"x1/2"~3/8"x3/8"

Variants

Code Description

01001002-01 E.Z. Feed Water Connector 1/4" - 1/2"x1/2"

01001002-02 E.Z. Feed Water Connector 1/4" - 3/8"x3/8" (20)

Code: 01001003

E.Z. Feed Water Connector, with Free Degree Nut 3/8" - 3/4"x3/4"

Variants

Code Description

01001003-02 E.Z. Feed Water Connector, with Free Degree Nut 3/8" - 3/4"x3/4" (10)

(12)

Code: 01001004

E.Z. Feed Water Connector, M.F. 3/4"x3/4"

Code: 01001005

E.Z. Feed Water Connector 1/4" - 3/4"x3/4"

Code: 01001006

E.Z. Feed Water Connector, with Free Degree Nut 1/4" - 1/2"x1/2"~3/8"x3/8"

Variants

Code Description

01001006-01 E.Z. Feed Water Connector, with Free Degree Nut 1/4" - 1/2"x1/2"

01001006-02 E.Z. Feed Water Connector, with Free Degree Nut 1/4" - 3/8"x3/8"

(13)

Clip

Code: 01008001

Single clip 2" - 2,5" - 3" - 3,5"

Variants

Code Description

01008001-02 Single clip 2"

01008001-01 Single clip 2,5"

01008001-03 Single clip 3"

01008001-04 Single clip 3,5"

Code: 01008002

Double Mounting clip 2"x2" - 2"x2,5" - 2,5"x2,5"

Variants

Code Description

01008002-01 Double Mounting clip 2"x2"

01008002-02 Double Mounting clip 2"x2,5"

01008002-03 Double Mounting clip 2,5"x2,5"

Code: 01008003

Double Mounting clip 2" - 2,5"

(14)

Variants

Code Description

01008003-01 Double Mounting clip 2"

01008003-02 Double Mounting clip 2,5"

Tube inserts

Code: 01006001

Tube inserts 1/4" ~ 3/8"

Variants

Code Description

01006001-01 Tube insert 1/4"

01006001-02 Tube insert 3/8"

TDS regulators

Code: 01010002

TDS adjuster quick fitting 1/4"

Code: 01010003

TDS mixing valve 1/4" F.

(15)

Code: 01010004

TDS mixing valve 1/4" F. (25)

Code: 01010005

TDS mixing valve OD stem 1/4'"

H2O pressure reducers

Code: 01011001

Pressure gauge 1/4" OD 50 Radial ~ Posterior connections

Variants

Code Description

01011001-01 Pressure gauge 1/4" OD 50 Radial connections (0-10bar/145psi) 01011001-02 Pressure gauge 1/4" OD 50 Posterior connections (0-12bar/174psi)

(16)

Code: 01011002

Water pressure reducer 3/8"~1/2" with gauge coupling

Variants

Code Description

01011002-01 Water pressure reducer 3/8" F.F. with gauge coupling (30) 01011002-02 Water pressure reducer 1/2" F. F. with gauge coupling

Code: 01011004

Water valve pressure limiter quick fitting1/4", 3/8"

(2,7bar/40psi, 4,8bar/70psi)

Features

Connections (01): 1/4” Quick fitting

Connections (02): 3/8” Quick fitting

Connections (03): 1/4” Quick fitting

Adjustment (01): 2,7bar (40psi)

Adjustment (02): 2,7bar (40psi)

Adjustment (03): 4,8bar (70psi)

Flow rate: 15 L/min at 6,9bar (100psi)

Pressure: 20bar (300psi) max.

Temperature Rating: 40°C max.

Variants

Code Description

01011004-01 Water valve pressure limiter quick fitting 1/4" (2,7bar/40psi) 01011004-02 Water valve pressure limiter quick fitting 3/8" (2,7bar/40psi) 01011004-03 Water valve pressure limiter quick fitting 1/4" (4,8bar/70psi)

(17)

Co2 pressure reducers

Code: 01012001

XS Co2 pressure reducer for rechargeable cylinder

Variants

Code Description

01012001-01 XS Co2 pressure reducer rechargeable cylinder 7 BAR IN: W21,8-14FIL.X1" Key-30 Out: 1/8" f. thread 01012001-02 XS Co2 pressure reducer rechargeable cylinder 5 BAR IN: W21,8-14FIL.X1" Key 30 Out: 1/8" f. thread

Galvanic NSF61 food coating Standard UNI EN ISO 2503

CO2 and N2 Pressure Regulators are Tested singly Internal high pressure valve in INOX AISI 300 Teflon gasket

Code: 01012002

XS Co2 pressure reducer for disposable and rechargeable cylinder

Variants

Code Description

01012002-01 XS Co2 pressure reducer for disposable cylinder 7,0 BAR IN: M11x1-Out: 1/8" f. thread

01012002-02 XS Co2 pressure reducer rechargeable cylinder 7 BAR IN: W21,8-14FIL.X1" Key 30 - Out: 1/4" f. thread 01012002-03 XS oring replacement IN Co2 for cod. 01012002-01 6,75x1,78x10,31

Galvanic NSF61 food coating Standard UNI EN ISO 2503

CO2 and N2 Pressure Regulators are Tested singly Internal high pressure valve in INOX AISI 300 Teflon gasket.

(18)

Code: 01012003

XS Co2 pressure reducer ACME Cylinder connection 4,5bar

* Low pressure gauge 4.5 bar rear connection * Handle for easy disassembly * 304 AISI Stainless Steel * IN: ACME thread * OUT: 1/8" NPTF F. thread

Code: 01012004

SR-02 Co2 pressure reducer for disposable cylinder

Variants

Code Description

01012004-01 SR-02 Co2 pressure reducer for disposable cylinder knob straight 11x1 connection 01012004-02 SR-02 90 Co2 pressure reducer for disposable cylinder knob to 90° 11x1 connection 01012004-03 SR-02 replacement gasket for cylinder fitting

SR-02 has everything you need for your safety and always to have under control the operating parameters of your installation of CO2 and N2.

* Material Aluminum HR

* Treatment Anodized

* Input Pressure From 1 to 160 bar

* Output Pressure Adjustable

* Gauges output pressure

* Safety Overpressure (Pop-Off)

* In Female thread: 11x1 (disposable cylinder) or 21.8X1/14 "(rechargeable cylinder) via adapter extension.

* Out female thread: 1/8"

* Flow Rate 15 l/min.

(19)

Code: 01012005

SR adapter extension Co2 pressure regulator for rechargeable cylinders M11x1 a W21.8x1/14"

From M11x1 to W21.8x1/14"

With this adapter, it is possibile to use the pressure reducer with rechargeable cylinders.

Code: 01012006

SR-02 Co2 pressure reducer for rechargeable cylinder

Variants

Code Description

01012006-02 SR-02 Co2 pressure reducer for rechargeable cylinder knob to 90°

SR-02 has everything you need for your safety and always to have under control the operating parameters of your installation of CO2 and N2.

* Material Aluminum HR

* Treatment Anodized

* Input Pressure From 1 to 160 bar

* Output Pressure Adjustable

* Gauges output pressure

* Safety Overpressure (Pop-Off)

* In Female thread: 11x1 (disposable cylinder) or 21.8X1/14 "(rechargeable cylinder) via adapter extension.

* Out female thread: 1/8"

* Flow Rate 15 l/min.

(20)

Code: 01012007

SR-02 ADV Co2 pressure reducer for rechargeable cylinder 21.8x1/14" (2 gauges)

SR-02 ADVanced has everything you need for your safety and always to have under control the operating parameters of your installation of CO2 and N2. It gives you protection against overpressure and pressure fluctuations in output. It makes you check the filling of the cylinder. Lets you precisely adjust the pressure of use. The two pressure gauges indicate the charge of the cylinder and the outlet pressure of CO2.

* Material Aluminum HR

* Treatment Anodized

* Input Pressure From 10 to 160 bar

* Output Pressure 0-6 bar (Adjustable)

* Gauges DN 40 low pressure [0-10 bar], Hight pressure [0-250 bar]

* Safety Overpressure (Pop-Off)

* In Female thread: 21.8X1/14"(rechargeable cylinder)

* Out female thread: 1/8"

* Flow Rate 15 l/min.

* Dimensions: 74X130 Ø38mm Code: 01012019

Replacement Co2 pressure gauge OD 0-250 Bar BSP 1/8" (high pressure) for cod. 01012007

The pressure gauges can be mounted in all the pressure reducers with predisposition, following the correct mounting.

To assemble the high-pressure pressure gauge in the HP marked port. The opposit port is dedicated at LP low-pressure pressure gauge mounting.

Don't assemble the LP low-pressure pressure gauge in the HP high-pressure pressure gauge dedicated port.

(21)

Code: 01012020

Replacement Co2 pressure gauge OD 40 0-10,0 Bar BSP 1/8"

(low pressure) for cod. 01012007

The pressure gauges can be mounted in all the pressure reducers with predisposition, following the correct mounting.

To assemble the high-pressure pressure gauge in the HP marked port. The opposit port is dedicated at LP low-pressure pressure gauge mounting.

Don't assemble the LP low-pressure pressure gauge in the HP high-pressure pressure gauge dedicated port.

Code: 01012008

SR-02 90 Co2 pressure reducer ACME Cylinder connection

Pressure reducer low-profile with connection ACME. This regulator requires an height only 2 cm (0.78 inch) allowing the use of ACME cylinders in very small spaces. Mounting and dismounting from the cylinder will not require tools.

* Material Aluminum HR

* Treatment Anodized

* Input Pressure From 1 to 160 bar

* Output Pressure Adjustable 0-5,5 bar

* Gauges output pressure

* Safety Overpressure (Pop-Off)

* In Female thread: ACME

* Out female thread: 1/8"

* Flow Rate 15 l/min.

(22)

Code: 01012009

SR adapter extension Co2 pressure regulator from ACME to M11x1

With this adapter, it is possibile to use the pressure reducer from rechargeable cylinders to disposable cylinders.

Code: 01012010

SR-02 Co2 pressure reducer for rechargeable cylinder knob straight

Variants

Code Description

01012010-01 SR-02 Co2 pressure reducer for rechargeable cylinder knob straight 01012010-02 SR-02 replacement gasket for cylinder fitting

SR-02 has everything you need for your safety and always to have under control the operating parameters of your installation of CO2 and N2.

* Material Aluminum HR

* Treatment Anodized

* Input Pressure From 1 to 160 bar

* Output Pressure Adjustable

* Gauges output pressure

* Safety Overpressure (Pop-Off)

* In Female thread: 11x1 (disposable cylinder) or 21.8X1/14 "(rechargeable cylinder) via adapter extension.

* Out female thread: 1/8"

* Flow Rate 15 l/min.

(23)

Code: 01012011

Replacement red gasket for cod. 01012001-01/-02, 01012002-02

Code: 01012012

Replacement Co2 pressure gauge Ø40-G1/8 0-6 BAR for cod.

01012001-01/-02, 01012002-01

Code: 01012016

Replacement Co2 pressure gauge Ø50-Scale BAR and PSI-Full scale 250 BAR for cod. 01012002-02

Code: 01012017

Replacement Co2 pressure gauge Ø50-Scale BAR and PSI-Full

scale 10 BAR-Notch 7 BAR for cod. 01012002-02

(24)

Code: 01012013

SR-Micro Co2 pressure reducer for disposable cylinder

Variants

Code Description

01012013-01 SR-Micro Co2 pressure reducer for disposable cylinder 11x1 disposable connection

The SR-Micro, thanks to a new system presetting "Adaptive comparison" you can forget the classical gauge. Indeed, the pressure (controlled) is indicated with precision (2.5% KI) on the reducer. This has enabled a compact reducer and incredible reliability, SR-Micro is all made of anodized aluminum alloy, stainless steel and, on request, holes forwall bracket (M5).

Material: Aluminum HR

Input Pressure From 10 to 120 bar Output Pressure: Adjustable (0 - 5,5bar) Safety: Overpressure (Pop-Off)

Connection Cartr. M11x1 / DIN / ACME Output: 1/8" F

Flow Rate: 12 L/min Code: 01012014

SR-Micro Co2 pressure reducer ACME connection

Variants

Code Description

01012014-01 SR-Micro Co2 pressure reducer ACME connection

The SR-Micro, thanks to a new system presetting "Adaptive comparison" you can forget the classical gauge. Indeed, the pressure (controlled) is indicated with precision (2.5% KI) on the reducer. This has enabled a compact reducer and incredible reliability, SR-Micro is all made of anodized aluminum alloy, stainless steel and, on request, holes forwall bracket (M5).

Material: Aluminum HR

Input Pressure From 10 to 120 bar Output Pressure: Adjustable (0 - 5,5bar) Safety: Overpressure (Pop-Off)

(25)

Connection Cartr. M11x1 / DIN / ACME Output: 1/8" F

Flow Rate: 12 L/min Code: 01012015

Replacement white gasket for cod. 01012008, 01012014-01

Code: 01012018

Replacement Co2 pressure gauge OD 40 0-10,0 Bar OT 1/8"

back connection

For cod. 01012004-01/-02, 01012008, 01012006-02, 01012010-01.

Ball valves

Code: 01002001

Ball Angle Valve 90° ( P.V.C.) for tank 1/4"x1/4" ~ 1/4"x3/8"

Variants

Code Description

01002001-01 Ball Angle Valve 90° ( P.V.C.) for tank 1/4" x 1/4"

(26)

Code: 01002002

Ball Valve with compression fitting 1/4"x1/4" ~ 1/4"x3/8"

Variants

Code Description

01002002-01 Ball Valve with compression fitting Thread 1/4" x quick fitting 1/4"

01002002-02 Ball Valve with compression fitting Thread 1/4" x quick fitting 3/8"

Code: 01002003

Ball Valve 1/4" - Tube 1/4" quick fitting

Code: 01002006

Ball valve with compression fitting - Tube 1/4" - Thread 1/2" M.

x 1/2" F.

(27)

Code: 01002004

Mini Ball Valve M.F. Black handle 1/4" ~ 3/8 ~ 1/2" (25)

Variants

Code Description

01002004-01 Mini Ball Valve M.F. Black handle 1/4" x 1/4" (24) 01002004-02 Mini Ball Valve M.F. Black handle 3/8" x 3/8" (20) 01002004-03 Mini Ball Valve M.F. Black handle 1/2" x 1/2" (20)

Code: 01002005

Ball Valve Mini F.F. Black handle 1/4" ~ 3/8 ~ 1/2" (25)

Variants

Code Description

01002005-02 Ball Valve Mini F.F. Black handle 1/4" x 1/4" (25) 01002005-03 Ball Valve Mini F.F. Black handle 3/8" x 3/8" (25)

Diverter valves

Code: 01005001

DV-14 Single diverter valve hose stem 1/4"

(28)

Check valves

Code: 01009001

Check valve OD Tube 1/4"

Water Block valves

Code: 01013002

Water Block valve with and w/o instant reset

Variants

Code Description

01013002-01 Water Block valve

01013002-02 Instant reset for water block

The valve Water Block is a Security instrument anti-flooding used to control the passage of a volume of water between 5 and 50 liters.

Its fuction is to measurement of the passage of the water and if this quantity is more than that fixed.

It stop immediatelly

Ideal for all machines that run with water. treatment systems. osmosis. dishwasher. washing machines.

He does not need energy from outside, because 'to operate using the stream that flows within it.

Resistant, environmental conditions limit.

Resistance to temperature changes.

Resistance to moisture.

Resistance to oxidation.

The device counts the quantity of water passed.

The average of the past for each notch of adjustment 4,5 - 5 liters.

Features:

* Number notches adjustment: 10

* Increase for each number: 4.5 - 5 liters

(29)

* Volume control max: 45 - 50 liters

* Temperature: The water inlet must not exceed 70 °C

* Flow rate: 2 to 30 l / min.

* Power Consumption: does not require electrical connections.

* Pressure: min. 0.2 - max. 10 bar.

* Connection to the pipes: the attacks are female threaded 3 / 4 "input side filter. Male-threaded 3 / 4"

output.

* Dimensions: 90mm x 5Ø

In case of block the valve can easily be and quickly reboot with the lever that is not essential for its installation.

Code: 01013003

AS-413, AS-414 Water Leak Blocker with Auto Shut Off Valve

Variants

Code Description

01013003-01 AS-414 Water Leak Blocker IN/OUT 1/2" BSP male plastic solenoid valve 01013003-02 AS-413BR Water Leak Blocker IN-OUT 3/8" BSP M./F. brass solenoid valve 01013003-03 AS-414BR Water Leak Blocker IN-OUT 1/2" BSP M./F. brass solenoid valve

Features:

* Auto shut off water when water leak is detected

* 9V alkaline battery operated

* Auto shut off when low battery power

* Easy installation

* Protection for water filter, water softener Specification:

* Operating voltage: 9V DC

* Supply current: typical 1.0 mA, maximum 15.0 mA.

* Cable length: 1.5 M for solenoid valve cord

* Water leak detecting method: Control unit with detecting metal put on the floor near water filter

* Environment temperature: -20 ~ 80°C.

* AS-414 Maximum Pressure: 6 Bar

* AS-413BR, AS-414BR Maximum Pressure: 8 Bar Operating instruction

Installation:

1-Install the proper fitting with the solenoid valve. The thread of solenoid valve is 3/8" or 1/2”. Then connect the inlet tube of the water treatment system with the solenoid valve.

2-Reset to work

Keep pressing button for 4 seconds, the control unit activates solenoid valve to open the inlet tube of water treatment system, and generates a long beep sound.

3-Auto shut off when water leak is detected

(30)

the control unit activates solenoid valve to open the inlet tube of water treatment system again with a long beep sound.

4-Low power shut off

When the battery power is low, the control unit shuts off the inlet tube of the water treatment system, blinks red light and generates an acoustic signal “beep” to notify that the battery needs to be replaced to keep water leak protection be functional.

Code: 01013004

Mechanical leaking sensor 1/4"

Variants

Code Description

01013004-01 Mechanical leaking sensor 1/4"

01013004-03 Mechanical leaking sensor 3/8"

01013004-02 Replacement instant wet towel-coin tissue for mechanical leaking sensor

Functioning: It is installed under the water purifier with 2 screws or double-sided tape present in the pack.

Base predisposed for 2 screws. When the towel-coin is wet, it expands and activates the water locking mechanism.

In-let and drain valves

Code: 01003001

SV-6 Saddle Valve , Tube 1/4"

(31)

Code: 01003002

Drain Clamp 1/4"

Variants

Code Description

01003002-02 Drain Clamp 1/4" Black

Code: 01003003

Drain Clamp quick fitting 1/4", 3/8"

Variants

Code Description

01003003-14 Drain Clamp quick fitting 1/4"

01003003-38 Drain Clamp quick fitting 3/8"

(32)

Riferimenti

Documenti correlati

The larger the bequest, the less likely it is that such a generation will need to borrow in his first period of life in order to smooth consumption and, therefore, also the less

Upon construction, the large external wall facing the river will appear as a finely designed artifactual element capable of protecting, with its peremptory nature and its mass,

The Chemical Time Bomb Concept (CTB) refers to “events resulting in the delayed occurrence of harmful effects due to the mobilization of chemicals stored in soils and sediments”..

Therefore, when we think that the stochastic process of a certain application looses memory, tend to assume values independent from those at the beginning, as time goes to in…nity,

Additionally, the dipole moment of trans-propargylamine was determined by Stark effect mea- surements (the values µ a = 0.586 D and µ b = 0.445 D being derived), but the very

Children affected by juvenile idiopathic arthritis show problems about the contact with the external world, underestimation of himself and inadequate perception of himself,

[r]

Refinements of the (UAMP) are established for higher order ODE’s with periodic boundary conditions in [5], for general second order PDE’s with Neumann or Robin boundary conditions