C CH HE EM MI IC CA AL L E EN NG GI IN NE EE ER RI IN NG G T TR RA AN NS SA AC CT TI IO ON NS S

VOL. 29, 2012

A publication of

The Italian Association of Chemical Engineering Online at: www.aidic.it/cet Guest Editors: Petar Sabev Varbanov, Hon Loong Lam, Jiří Jaromír Klemeš

Copyright © 2012, AIDIC Servizi S.r.l.,

ISBN 978-88-95608-20-4; ISSN 1974-9791 DOI: 10.3303/CET1229131

Integrating the Compression Heat in Oxy-combustion Power Plants with CO

2

Capture

Chao Fu*, Truls Gundersen

Norwegian University of Science and Technology, Department of Energy and Process Engineering, Kolbjoern Hejes vei 1.A, NO-7491 Trondheim, Norway

chao.fu@ntnu.no

Oxy-combustion is a competitive technology to enable the capture of CO2 from fossil fuel based power plants. Cryogenic air separation is the only commercially available technology for large volume O2

production that can be applied for oxy-combustion plants. The considerable energy consumption in the air separation units is the main challenge to implement oxy-combustion technology. The compression heat in the air compression process is generally removed by cooling water. The water coolers are responsible for 17.6 % of the total exergy losses in an air separation unit. This paper investigates the possibilities of integrating the compression heat from the air separation unit with the steam cycle. The compression process of the air is studied in two cases: adiabatic (one-stage) compression and three- stage compression with interstage cooling. A decomposed methodology has been developed for studying the heat balance in the boiler feedwater heaters in the steam cycle. The Grand Composite Curve is applied to determine the heat demand and thus the amount of steam extraction. For a coal based oxy-combustion power plant with a gross power output of 792 MW, the thermal efficiency increases with 0.47 % points (net power increases by 8.8 MW) by heat integration in the adiabatic compression case.

1. Introduction

Several studies indicate that oxy-combustion is a promising technology for CO2 capture from fossil fuel based power plants, particularly from coal based power plants (DOE/NETL, 2008, Fu and Gundersen, 2010, Wall et al., 2009). The core concept of oxy-combustion is to use high purity oxygen instead of air for the combustion process so that the flue gas is composed mainly of CO2 and H2O. The CO2 can be separated by condensing the H2O and then purified by chilling. The main challenge for implementing this technology is that a large power penalty is caused by the air separation unit (ASU). A 500 MWe power plant will consume around 10,000 t/day O2 (Higginbotham et al., 2011). Cryogenic air separation is the only commercially available technology for large volume O2 production. For a coal based oxy- combustion power plant, the thermal efficiency penalty caused by the air separation unit (ASU) is around 6.6 % points (based on the higher heating value, HHV) when a traditional double-column distillation cycle is applied for O2 supply (Fu and Gundersen, 2010).

The air feed compression process in a cryogenic ASU is responsible for 38.4 % of the total exergy losses, where the water coolers are responsible for 17.6 % of the total losses (Fu and Gundersen, 2012). The water coolers are used to remove the compression heat, thus reduce the compression work.

Since the compression heat is low grade, it is normally regarded as having little value. A model for utilizing the low-grade heat (30 – 250 oC) in site utility systems is presented by Kapil et al. (2010). For oxy-combustion power plants, the low grade compression heat could be integrated with the steam

(2)

cycle by partially preheating the boiler feedwater, thus less steam is extracted for the preheating process. Romeo et al. (2009) investigated the possibility of utilizing the compression heat from the compression process of CO2 for the preheating of boiler feedwater in the low pressure section. The total power saving is reported to be around 40 % of the power consumption for the CO2 compression when the compression heat is utilized. This paper presents a study on the heat integration between the compression heat from the ASU and the steam cycle in a coal based oxy-combustion power plant. A decomposed methodology has been developed for investigating the heat balance in each boiler feedwater heater. The Grand Composite Curve (GCC) is used to determine the load (amount) and the level (temperature) of the extracted steam.

2. The steam cycle

The ASU and the entire oxy-combustion power plant are described by Fu and Gundersen (2010). The ambient air is compressed to 5.6 bar (absolute pressure is used in this paper). The flowsheet of a detailed supercritical steam cycle is presented in Figure 1 (DOE/NETL, 2008). The steam cycle has 4 closed feedwater heaters in the low pressure section (FWH1-4) and 3 in the high pressure section (FWH6-8). The high pressure (HP) steam is heated to 242 bar / 599 oC with single reheat of the intermediate pressure (IP) steam to 45 bar / 621 oC. The condenser pressure is 0.069 bar. The gross power generation from the steam cycle is 791 953 kW. The thermal input by the fuel is 1 878 556 kW (based on the higher heating value, HHV). This steam cycle is used as the reference case in the paper.

HP IP LP Generator

FWH8 FWH7 FWH6

Boiler Feed Pump

Deaerator

FWH4 FWH3 FWH2 FWH1

Gland Seal Condenser

Condensate Pump Steam Seal

Regulator

Condenser Boiler Feed Pump

Turbine Drives

Makeup Water

To Boiler Reheat Extraction

To Boiler Main Steam Reheat Steam

To Flue Gas Recycle Reheater

From Flue Gas Recycle Reheater

N1

N2

N3 N4

N5 N6 N7

N8 N9

N10 N11

N12

N13

N14

N16 N15

N18 N17

N19

N20 N21

N22 SASUa SCPUa

SASUbSCPUb

N23

N24

N25 N26 N27

N28 N29

N31 N32

N4-1 N4-2

N30

N4A N4B

Figure 1: The supercritical steam cycle

3. Heat integration

When the compression heat is integrated with the steam cycle, the heat is transferred from the compressed gases to the boiler feedwater. The minimum temperature difference for the gas/water heat exchangers is specified to be 10 oC, and for the steam/water heat exchangers it is assumed to be the same as in the reference case. The steam seal regulator (SSR) and the deaerator are assumed not to be influenced by the heat integration. Thus the temperature of the boiler feedwater to FWH1 (N3) is maintained (39.1 oC). The compressed gases can be cooled to around 49.1 oC by the boiler feedwater.

The integration study is performed by the following steps:

(1) Determine the supply temperature of the compression heat and thus the FWHs by which the compression heat can be integrated.

(3)

(2) Draw the Grand Composite Curve (GCC) when assuming that no steam is extracted for the FWHs that can utilize the compression heat.

(3) Use the GCC to determine the demand of the extracted steam at different pressure levels (the pressure levels are maintained as in the reference case). The condensed water in each FWH flows into the next lower pressure FWH (the deaerator and the gland seal condenser can be regarded as special FWHs), thus supplies a small portion of heat for the lower pressure FWH.

This portion of heat is neglected when determining the demand of extracted steam, and primarily used when designing the FWHs. Thus, the compressed gases will be cooled to temperatures higher than 49.1oC, resulting in larger temperature driving forces in the gas/water heat exchangers.

(4) Further cooling of the compressed gases to 35.1oC by cooling water to reduce the compression work or cooling duty in other heat exchangers.

In order to determine the mass flow of the extracted steam based on the GCC, the heat loads for the FWHs are decomposed based on the heat supplied by each extracted steam flow. The decomposed heat loads in the reference case are shown in Figure 2. The external drain coolers (flash type) are used (STEAM PRO 21.0, 2012). The condensate from each FWH is flashed to a lower pressure and condensed again at the lower saturation temperature. Thus the temperature of each extracted steam does not decrease continuously.

3.1 Case 1: Three-stage compression in the ASU

The excess O2 in the combustor is around 10 wt%. The ambient air (1.013 bar, 25 oC, 78 617 kmol/h) is compressed to 5.6 bar by a three-stage compression process with interstage cooling. The compression ratio for each stage is equal (1.768). The three heat streams from the outlet of each compression stage are: Q11 (88.9→49.1 oC), Q12 (101.1→49.1 oC) and Q13 (101.1→49.1 oC). The heat capacity is assumed constant and the same for the three heat streams. The mean heat capacity

(a)

FWH4 FWH3 FWH2 FWH1

147.1oC 103.3oC

N7 87144 kW N6 43392 kW N5 44611 kW N4 42511 kW N3

305.1oC 150oC

108.9oC

5849 kW 5849 kW 81294 kW

86.8oC 3095 kW 167.6oC

106.1oC 86.8oC 38957 kW 1339 kW

66.6oC 2858 kW

66.6oC 1415 kW 97.4oC

84.1oC 66.6oC 36427 kW 1168 kW

2952 kW 1461 kW 1390 kW

45.1oC 45.1oC 45.1oC 63.5oC

45.1oC 35432 kW 1193 kW

103.3oC 81.5oC 81.5oC 62.6oC 60.8oC 39.1oC 383.5oC 84.1oC 66.6oC

2673 kW 69 kW

82 kW 45.1oC N24

N25 N28

N26

N27

(b)

260.5oC

FWH6 FWH7

FWH8

291oC 411.4oC

290.4oC

70101 kW 19720 kW

N12 N11 260.5oC

89821 kW

260.8oC

7264 kW 260.8oC 349.6oC

16900 kW 101078 kW

125252 kW

215.4oC N10 N9

10534 kW 215.4oC 182oC

214.3oC 214.3oC

13507 kW 17025 kW 48026 kW 499oC

214.3oC

89092 kW

N16 N15 N18

Figure 2: Decomposed heat loads in the FWHs: (a) FWH1-4; (b) FWH6-8

(4)

flowrate is calculated to be 641 kW/oC. Based on the supply temperatures, the compression heat can be used to reduce the steam consumption in FWH1-3. Assuming that no steam is extracted for FWH1- 3, i.e. the heat is supplied by the compression heat, the condensed water from FWH4, and the steam from the SSR (N28; the sensible heat is very small and thus not included in the GCC), the GCC is shown in Figure 3.

0 20 40 60 80 100 120

0 5000 10000 15000 20000 25000 30000 35000 40000

T (°C)

Q (kW) FWH3: 31085 kW FWH2:

6691 kW

Figure 3: The GCC for FWH1-3 in Case 1

FWH4 FWH3 FWH2

147.1oC 103.3oC

N7 87144 kW N6 43392 kW N5 44611 kW N4 42511 kW N3

305.1oC

150oC 108.9oC

5849 kW 5849 kW 81294 kW

86.8oC 3095 kW 167.6oC

106.1oC 86.8oC 31085 kW 1068 kW

66.6oC 2858 kW 66.6oC 1129 kW 97.4oC

84.1oC 66.6oC 6691 kW 214 kW

2952 kW 1165 kW 255 kW

45.1oC 45.1oC 45.1oC

103.3oC 81.5oC 81.5oC 62.6oC 60.8oC 39.1oC 383.5oC 84.1oC 66.6oC

2673 kW 69 kW

82 kW 45.1oC FWH1

N24 N25 N28

N26

Figure 4: Decomposed heat loads for FWH1-4 in Case 1

N3

42511 kW 4454 kW

45.1oC 39.1oC FWH1

41.4oC 4270 kW

66.6oC 64.4oC

60.8oC 62.6oC 9364 kW

84.1oC 383.5oC

97.4oC

77.5oC 81.5oC

38057 kW 30977 kW

44611 kW 4163 kW

86.8oC 83.6oC

43392 kW 31085 kW

106.1oC 167.6oC

103.3oC

8144 kW 87.6oC 101.1oC

94.7oC 94.7oC

88.9oC 76.6oC 76.6oC

56.8oC FWH2

FWH3

N6

Figure 5: Heat balance for FWH1-3 in Case 1

Based on the GCC, the heat demands for the feedwater heaters are 31 085 kW (FWH3), 6 691 kW (FWH2), and 0 kW (FWH1). The mass flow of the extracted steam can thus be determined based on Figure 2, and is shown in Table 1. The new decomposed heat loads in FWH1-4 are illustrated in Figure 4. When the compression heat is added, heat balance can be achieved in FWH1-3. One possible

(5)

thermal configuration of the boiler feedwater preheating process is shown in Figure 5. The compression heat is illustrated by the dotted lines. In this case, the compressed air is first cooled to 56.8 oC. The heat is used to preheat the boiler feedwater. The air is then cooled to 35.1 oC by cooling water (not shown in Figure 5). The boiler feedwater in each FWH is first slightly heated in an external drain cooler (flash type) by the condensate in the FWH (including the condensate from higher pressure FWHs), then heated by the compressed gases, and finally heated by the extracted steam (if necessary). Based on Figure 5, the heat exchanger network can be directly obtained and is shown in Figure 6. The multi-stream gas/water heat exchangers can be easily separated into regular two-stream heat exchangers by splitting the boiler feedwater into several streams.

LP Generator

FWH4 FWH3 FWH2 FWH1

Gland Seal Condenser

Condensate Pump Steam Seal

Regulator

Condenser

To Flue Gas Recycle Reheater

From Flue Gas Recycle Reheater

N1

N2

N5 N3 N6

N24

N26 N28

N29 N33 N34

N4-1 N4-2

N30

N31 N32

N4

Compressed Air

Cooling Water Cooling Water N7

Ambient Air

Cooling Water N25

Figure 6: A possible integration scheme for Case 1

3.2 Case 2: Adiabatic compression in the ASU

The ambient air is compressed to 5.6 bar by a one-stage compressor. Thus there is only one heat stream: 250.2→49.1 oC, 650 kW/oC. The temperature of the compression heat is lifted due to the adiabatic process, thus the compression heat can be used to reduce the steam consumption in FWH1- 4 and FWH6-7. The resulting extra steam from the outlet of the HP steam turbine is assumed to expand to the condenser pressure through a one-stage turbine. Following the procedure described in the beginning of Section 3, the plant performance can be investigated.

3.3 Plant performance comparison

The plant performance for the reference case and the two integration cases is shown in Table 1. In the reference case, the compression process in the ASU is the same as in Case 1, however, the compression heat is removed by cooling water and thus wasted. When the low grade compression heat is used for preheating the boiler feedwater, the power generated by the steam turbines increases by 7 180 kW, resulting in an increase of the thermal efficiency by 0.38 % points. In the adiabatic compression case, more work (20 999 kW) is consumed in the ASU. However, the compression heat is upgraded (the temperature is lifted) and can be used to reduce the steam extraction in the high pressure section, resulting in an increase of the thermal efficiency by 0.47 % points.

(6)

The compressor efficiency is assumed constant and the same for the three cases in this paper. In practice, the compressor efficiency will change with the operating temperature. The temperature differences of the gas/water heat exchangers are also different in the three cases. In addition, the plant performance is influenced by the compression ratio of each compression stage and the supply/target temperatures. The choice of compression scheme in the ASU tailored for heat integration is a complex optimization problem (including investment cost) and needs further investigation.

Table 1: Results for the heat integration between the ASU and the steam cycle

Reference case Case 1 Case 2 Hot end temperature of the compressed gases, oC 101.1 101.1 250.2 Cold end temperature of the compressed gases, oC / 56.8 69.9

Work consumption in the ASU, kW 119,029 119,029 140,038

Power generated from steam turbines, kW 791,953 799,133 821,730

Net power increment, kW / 7,180 8,768

Thermal efficiency increment (HHV), % points / 0.38 0.47

Mass flow of extracted steam, kg/s

N15 60.995 60.995 53.814

N16 47.57 47.57 47.57

N18 25.515 25.515 16.753

N24 33.281 33.281 15.956

N25 16.477 13.148 12.98

N26 15.674 2.87 13.327

N27 15.481 0 12.511

4. Conclusions

The energy penalty related to CO2 capture in oxy-combustion power plants is mainly caused by the energy intensive cryogenic air separation unit. The air is normally compressed by multi-stage compressors in the air separation unit. The compression heat is removed by cooling water in order to reduce the temperature of the compressed gases and thus the compression work. A decomposed methodology has been developed in this paper for integrating the compression heat with the steam cycle. For a coal based oxy-combustion power plant with CO2 capture (gross power output: 792 MW), the thermal efficiency increases by 0.38 % points (net power increases by 7.2 MW) when the compression heat is integrated with the steam cycle. If an adiabatic compression scheme is applied, the thermal efficiency increases by 0.47 % points (net power increases by 8.8 MW). Further investigations on the optimal compression scheme in the air separation unit are required.

References

DOE/NETL, 2008, Pulverized coal oxycombustion power plants, Technical report, 2007/1291.

Fu C., Gundersen T., 2010, Heat integration of an oxy-combustion process for coal-fired power plants with CO2 capture by pinch analysis, Chemical Engineering Transactions, 21, 181-186.

Fu C., Gundersen T., 2012, Using exergy analysis to reduce power consumption in air separation units for oxy-combustion processes, Energy, DOI:10.1016/j.energy.2012.01.065.

Higginbotham P., White V., Fogash K., Guvelioglu G., 2011, Oxygen supply for oxyfuel CO2 capture, Int. J. Greenhouse Gas Control 5S, S194-203.

Kapil A., Bulatov I., Kim J-K., Smith R., 2010, Exploitation of low-grade heat in site utility systems, Chemical Engineering Transactions, 21, 367-372.

Romeo L.M., Bolea I., Lara Y., Escosa J.M., 2009, Optimization of intercooling compression in CO2

capture systems, Appl. Therm. Eng. 29, 1744-1751.

STEAM PRO 21.0, 2012, Help document <www.thermoflow.com> accessed 19.05.2012

Wall T., Liu Y., Spero C., Elliott L., Khare S., Rathnam R., Zeenathal F., Moghtaderi B., Buhre B., Sheng C., Gupta R., Yamada T., Makino K., Yu J., 2009, An overview on oxyfuel coal combustion- state of the art research and technology development, Chem. Eng. Res. Des. 87, 1003-1016.

Riferimenti

Documenti correlati

In [10], in the framework of the extended rational thermodynamics with internal vari- ables, using the standard Cartesian tensor notation in a rectangular coordinate system, a model

This paper reports an experimental study of transient natural convection heat and mass transfer between two large cylindrical reservoirs connected through a short

The thermal efficiency of air heat pumps applied for the production of domestic how water is determined by a number of factors such as: course of tapping cycle, ambient

Data of the two heat pumps working during one heating season was analysed to determine the influence of heat sink temperature on the Seasonal Performance Factor.. Results of

By monitoring the energy drawn from the ground massif by VGHE during the heating period, it was possible to estimate the value of Coefficient of Performance (COP) for

Basing on the available measurement data (temperatures of: ground surface, borehole and heat-carrier fluid, and the borehole heat loads), the parameters of the ground were

reach daily heat generation from the compression system of 6829 GJ. In order to store this amount of heat it is necessary to use a heat accumulator with a water capacity of at least

Choosing a least-structure inversion strategy (i.e. gravity anomaly to Moho depth), to keep the dependence on other observables as limited as possible, we enquire with a set