Quantitative Analyses of Groundwater Flow from Thermal Tests and Temperature Logs

Massimo Verdoya, Paolo Chiozzi

DISTAV - Università di Genova, Viale Benedetto XV, 5, 16132 Genova, Italy

Temperature-time curves recorded during thermal tests in borehole heat exchangers are commonly analysed with the infinite line source (ILS) model assuming a purely conductive thermal regime. Results can be biased by the possible occurrence of groundwater flow. We investigated this flaw by simulating temperature-time signals with a moving line source (MLS) model under different hypothesis of Darcy velocity. A random noise was included in the synthetic data obtained with the MLS model in order to mimic high-frequency disturbances caused by several possible sources (e.g. testing conditions and geological variability) that often occur in real signals. The subsurface thermal conductivity, the Darcy velocity and the borehole thermal resistance were inferred by minimising the root mean square error between the synthetic dataset and the model. The calculated thermal and hydraulic parameters were consistent with the “a priory” values. The optimisation procedure was then tested with synthetic signals originated by the ILS model. For a Darcy velocity exceeding 10-7 m s-1, it turns out that ILS largely overestimates thermal conductivity. The approach relying on the MLS model was finally tested on temperature-time data from boreholes drilled in sedimentary aquifers. This produced reliable estimates of thermal conductivity, Darcy velocity and borehole thermal resistance. The magnitude of the inferred groundwater flow was checked by means of an independent method based on the analysis of temperature-depth logs recorded under thermal equilibrium conditions. The matching of thermal logs with analytical models incorporating both heat and mass transfer gave Darcy velocities in agreement with those inferred from the analysis with the MLS model.

Riferimenti

Documenti correlati

The combined effect of viscosity- and geometry-induced flow maldistribution on the thermal performance of cross-flow micro heat exchangers is investigated with reference to two

Analisi funzionale di alcuni campus realizzati in epoca contemporanea: individuazione della natura dei servizi svolti e della loro

The use of dynamic systems theory, applied to model development in old age (Schroots, 2012), seems to be a good basis to model HRQOL in the older adults, giving possible solutions

et ne sentez-vous pas ce que tout le mond sent, le besoin, la nécessité d’un révélateur, d’un redempteur, du messie que nous attendons et que nous voyons déjà dans nos

On the contrary, when salinity is such high to depress the freezing point to operational temperature (-6°C) like SJ140 sample, the percentage of unfrozen water arises until arrest

In order to evaluate the possibility of using groundwater from Quaternary formations in low-temperature geothermal systems in the Małopolska Province, data from 838 wells

The joint thermal-hydraulic tests can potentially reduce laboriousness (decrease in the number of involved operating conditions, reduction in the number of measurements to be

By monitoring the energy drawn from the ground massif by VGHE during the heating period, it was possible to estimate the value of Coefficient of Performance (COP) for