• Non ci sono risultati.

Conventional and enantioselective GC with microfabricated planar columns for analysis of real-world samples of plant volatile fraction

N/A
N/A
Protected

Academic year: 2021

Condividi "Conventional and enantioselective GC with microfabricated planar columns for analysis of real-world samples of plant volatile fraction"

Copied!
2
0
0

Testo completo

(1)

21 July 2021

AperTO - Archivio Istituzionale Open Access dell'Università di Torino

Original Citation:

Conventional and enantioselective GC with microfabricated planar columns for analysis of real-world samples of

plant volatile fraction

Publisher:

Terms of use:

Open Access

(Article begins on next page)

Anyone can freely access the full text of works made available as "Open Access". Works made available under a

Creative Commons license can be used according to the terms and conditions of said license. Use of all other works

requires consent of the right holder (author or publisher) if not exempted from copyright protection by the applicable law.

Availability:

Chromaleont

This is the author's manuscript

(2)

Conventional and enantioselective GC with micro-fabricated planar columns for analysis of real-world samples of plant volatile fraction

Cecilia Cagliero1, Stefano Galli2, Mario Galli2, Chiara Cordero1, Erica Liberto1, Barbara Sgorbini1, Patrizia Rubiolo1, Carlo Bicchi1

1 Dipartimento di Scienza e Tecnologia del Farmaco - Università di Torino, Via Pietro Giuria, 9, 10125 Torino, Italy

2 MEGA s.n.c., Via Plinio, 29, 20025 Legnano, Italy

Compact instrumentation, offering technical characteristics and performance comparable to those of conventional setups, has obvious benefits in terms of saving energy, materials, and laboratory space and affords the possibility of “in-field” applications.

In view of a possible application of on-chip GC for the in-situ analyses of the volatile fraction emitted from plants, this study evaluates the performance of a set of planar columns of different geometry installed in a conventional GC unit. The essential oils and the headspace samples of a group of medicinal and aromatic plants as well as standard mixtures of related compounds were analyzed with planar columns and the results were compared to those obtained with reference equivalent narrow-bore (NB) columns (l: 5m, dc: 0.1 mm, df: 0.1 µm). Planar columns were statically coated with the stationary phases (SP) commonly adopted to analyze the plant volatile fraction: dimethyl polysiloxane 5 % phenyl and acid-treated polyethylene glycol as apolar and polar SPs for conventional GC and a 30% 6I-VII-O-TBDMS-3I-VII-O

-ethyl-2I-VII-O-ethyl-β-cyclodextrin in PS-086 as chiral SP for enantioselective GC.

The tested planar columns showed performances close to the reference conventional NB columns, with theoretical plate numbers per meter (N/m) ranging from 6100 to 7200 for those coated with the conventional SP, and above 5600 for those with the chiral selector. They provide separations of the components of the investigated samples that perfectly overlaps that of the conventional NB column for both conventional and enantioselective GC. The chromatographic performances of conventional and planar columns were highly comparable, in both qualitative (ITS varying by a maximum of 7 units) and quantitative (RSD on the area percent and absolute concentrations below 10%) terms. These results show that all aspects required to characterize a plant volatile fraction (i.e. peak identification and quantitation, and chiral recognition) may be covered.

Riferimenti

Documenti correlati

On page 4 of our paper, talking about Hans Geiger, it is written "young Rutherford’s PhD student at the University of Manchester". This should be changed to "young

The selenite reduction and selenium formation were evaluated for A16 and SeITE strains in the presence of mercury in a liquid rich medium at 0.5 mM concentration of Na 2 SeO 3 .and

The amplitude of the oscillations A 0 (from min- imum to maximum velocity) is given in Table 1 together with their period and rms radial vorticity ζ assuming that the star is

By Willmore-type energy of an immersed manifold we mean a functional depending on the volume (length or area) of the manifold and on some L p -norm of the mean curvature.. of

Chemical composition and antimicrobial activity of the essential oils of some species of Anthemis sect. Anthemis (Asteraceae)

J/MNRAS/449/2438 Formamide detection with ASAI-IRAM (Lopez-Sepulcre+, 2015) Shedding light on the formation of the pre-biotic molecule formamide with ASAI.. While this molecule

PLANNING OF INTEGRATED SYSTEMS FOR SUPPLY OF NATURAL WATER AND UNCONVENTIONAL RESOURCE IN AGRICULTURE: THE FEASIBILITY OF MUNICIPAL SECONDARY EFFLUENTS REUSE IN IRRIGATION

Overall, spotty types outperformed single composition separators both in terms of peak power and AUC, suggesting a great potential of this ceramic design type as an MFC