• Non ci sono risultati.

External validation of PADUA classification for the renal tumor enucleation technique

N/A
N/A
Protected

Academic year: 2021

Condividi "External validation of PADUA classification for the renal tumor enucleation technique"

Copied!
1
0
0

Testo completo

(1)

External validation of PADUA classification for the renal tumor enucleation technique Vittori G., Minervini A., Salvi M., Tuccio A., Siena G., Mantella A., Sebastianelli A., Saleh O., Serni S., Carini M.

University of Florence, Dept. of Urology, Florence, Italy

INTRODUCTION & OBJECTIVES: The PADUA classification was introduced in 2009, but it has never been validated for the Tumor Enucleation (TE) technique. Aim of study was to assess the ability of PADUA score to predict the surgical results and complications of TE. MATERIAL & METHODS: We prospectively gathered data from 244 consecutive patients treated with open TE with warm ischemia. All clinical and surgical data, including PADUA score, were registered. The relationship between preoperative variables and surgical results/perioperative complications was assessed with univariate analysis and multivariate logistic regression model.

RESULTS: Median PADUA score of renal tumors resulted 8 (IQR:7-9), and it was ≥ 10 in 52 (21.3%) patients. Mean warm ischemia time (WIT) was 16.8 min. Overall, 47 perioperative complications occurred in 45 patients (45/244 = 18.4%); of these, 39 (16%) were surgical and 8 (3.3%) medical. Surgical complications included blood loss treated with bedrest in 2 patients (0.8%), with transfusions in 25 (10.2%) and with a second invasive procedure in 5 (2.1%) patients. Urinary fistula occurred in 7 patients (2.9%); it was treated with bedrest and antibiotics in 4 (1.7%), while it needed ureteral stenting in the other 3 cases (1.2%). According to Clavien system, 8 surgical complications were grade 3 ( 3.3%), and no grade 4 and 5 surgical complications occurred in this series.

At univariate analysis the PADUA score resulted significantly correlated with WIT (p<0.0001), estimated blood loss (p=0.003) and operative time (p=0.027). Significant predictors of overall surgical complications resulted the Charlson index (p<0.0001), the surgical indication (p=0.045), the tumor diameter (p=0.042) and the PADUA score (p=0.009). At the multivariate analysis, independent predictors of overall perioperative complications resulted PADUA score (RR=1.54; p=0.017) and the surgical indication (RR=2.59; p=0.019). Therefore, each point increase in PADUA score was associated with a 1.54-fold increase in the risk of complications after TE. The PADUA score was the only anatomical variable who independently predict the surgical complications (RR= 1.58; p=0.016), and Clavien grade III surgical complications (RR=2.99; p=0.008).

CONCLUSIONS: The PADUA score was significantly associated with the surgical results of TE, and it resulted an independent predictor of overall complications, surgical complications, and Clavien grade III complications.

Page 1 of 1 136 - External validation of PADUA classification for the renal tumor enucleation techniq...

4/6/2012 file://F:\RamShankar\April\04-05-12\Cip\Sour\136.html

Riferimenti

Documenti correlati

We have received more than 310 research articles for review in Early Bird Round from more than 34 countries and only 124 articles has been accepted for publication and oral

In this section we are going to recall the deformation sequence associated with a pointed scheme, which plays a role in the infinitesimal criterion for obstruction theories as

compared the effect of enzymatic and acid hydrolysis on different plant protein sources (soybean, rapeseed and guar protein meals), in terms of efficacy against the powdery mildew

The present study highlights that the technology of manufacture of plasters and mortars at Erimi- Laonin tou Porakou from EC III to LC IA was based on the use of

Si forma così una “secon- da realtà”, quella delle regolarità statistiche, che non ha – come tutte le realtà fi ttizie – alcuna corrispondenza nella realtà reale, ma

Over the new series a statistical analysis has been carried out and the extreme values, values that fall in the distribution tails, have been checked by examining the daily values

The irregular spectral behavior of the leakage loss in the low loss regions is due to the weak coupling of the core modes with dielectric modes having high

With this application you can Add Patient Record on patient visit, Set Follow-ups for next call revisit the clinic if needed, Get the details of each day records (Statistics),