Comparison of CO2 sensors MH-Z19B and CCS811

en.ovcharov.me/2020/06/10/co2-sensor-modules-comparison-ccs811-vs-mh-z19b

Jun 10, 2020 | smart home

Having two different CO2 sensors it makes sense to put them together and compare reading over some period of time.

And here is the picture of them:

Carbon dioxide sensors - MH-Z19B and CCS811

Sensors parameters, according to the manufacturer’s datasheets:

MH-Z19B CCS811

Sensor type infrared metal oxide Voltage 4.5V - 5.5V 1.8V - 3.6V Average current 60mA 30mA Measurement range 4000

-5000ppm 400 -29206ppm

(2)

Interface UART, PWM I2C

Price ~15 euro ~8 euro

MH-Z19B CCS811

Both sensors are designed to measure the level of carbon dioxide indoors.

The CCS811 sensor has many advantages over MH-Z19B - significantly smaller size, lover voltage and current, lower price.

For comparison, both sensors were connected to ESP8266 development boards with very similar firmware. Readings were collected every 10 seconds and sent by MQTT protocol to a Raspberry PI microcomputer with mosquitto - influxdb - grafana stack. The comparison ran for about one week, the sensors were on my working desk in a few centimetres from each other.

As a result, I have got the following chart:

In general, readings from both sensors visibly correlate. They have very similar ups and downs. However, CCS811 reacts much faster and with higher magnitude. I expected that the lines from the sensors will be much closer.

In the very beginning, the CCS811 showed a very strange peak of 8000ppm. The values returned to more or less normal after some time.

(3)

Other than that, the readings look quite similar. Here, for example, Monday’s chart:

Charts in the night time look more flat. It was quite chilly in the evening and windows were closed, so the values are higher than 400ppm for fresh air. In the morning it quickly became stuffy and I have opened the window. In the evening it was chilly again.

Conclusion

The result is very disappointing. I expected more comparable values from the sensors. Look, it’s really strange when one of the modules shows less than 1000ppm while the other one lying in just a few centimetres away shows more than 2000ppm. Which one is

(4)

right? Or both of them are incorrect?

Probably the modules itself are of bad quality. Probably temperature and humidity correction added to CCS811 will improve the results. Or, maybe, the case with filters like one in the MH-Z19B will help here. I don’t know.

Overall, CSS-811 reacts much faster. When I breathe directly on the sensor the value changes immediately and return back to normal almost in real-time.

Yes, both sensors react to the CO2 concentration. Changing the values depending on the environment changes clearly says about that. But which one is correct? To answer that question I need to repeat the experiment but together with a calibrated CO2 sensor which I do not have at the moment. Maybe at some point in the future.

Riferimenti

Documenti correlati

Classifiers resisted race schemes cluttered with local variation, dismissing proposed new races as merely local mix-types , but incentives to create new races

Current understanding, based on the noticeable, small, truly congenital nevi and nevi acquired early in life, is that the first develops before puberty, presents with a

His scholarship deals with topics that are still at the center of the contempo- rary constitutional debate, to mention just a few among the areas addressed in his many

The identification of functional roles for Sox2 in specific types of differentiated neurons and glia opens a new perspective in the understanding of the function of this

The inhibitory effect exerted by [SRSRY] on cytoskeletal organization and migration of M1 macrophages was not due to a reduced cell viability as the number of macro- phages exposed

The highest concentration of Pd-NPs (12 μg/kg) induced a statistically significant increase of IL-1α, IL-4, IL-6, IL-10, IL-12, GM-CSF and INF-γ compared to controls, while at the

Alessandro Degl'Innocenti, Antonella Capperucci & Miss Lucrezia Frateschi (2011): Synthesis of Enantiomerically Pure 1,2-Disubstituted 2-Selenoamines, Phosphorus, Sulfur,