• Non ci sono risultati.

Preliminary tests of innovative thin silicon detectors for beam monitoring in particle therapy.

N/A
N/A
Protected

Academic year: 2021

Condividi "Preliminary tests of innovative thin silicon detectors for beam monitoring in particle therapy."

Copied!
2
0
0

Testo completo

(1)

27 July 2021

AperTO - Archivio Istituzionale Open Access dell'Università di Torino

Original Citation:

Preliminary tests of innovative thin silicon detectors for beam monitoring in particle therapy.

Publisher:

Terms of use:

Open Access

(Article begins on next page)

Anyone can freely access the full text of works made available as "Open Access". Works made available under a Creative Commons license can be used according to the terms and conditions of said license. Use of all other works requires consent of the right holder (author or publisher) if not exempted from copyright protection by the applicable law.

Availability:

SIF

This is the author's manuscript

(2)

Title: Preliminary tests of innovative thin silicon detectors for beam monitoring in particle therapy Authors:

Anna Vignati – Author 2 Vincenzo Monaco – Author 1-2 Andrea Attili – Author 2 Nicolò Cartiglia – Author 2

Mohammad Fadavi Mazinani – Author 2 Simona Giordanengo – Author 2

Omar Hammad Ali - Presenting Author 1-2 Lorenzo Manganaro – Author 1-2

Giovanni Mazza – Author 2 Roberto Sacchi – Author 1-2 Amedeo Staiano – Author 2 Federico Fausti – Author 2-3 Marco Donetti –Author 4 Marco Ferrero – Author 2 Marco Mandurrino – Author 2 Valentina Sola – Author 2

Roberto Cirio - Senior Author 1-2

(1) Physics Department, Universita’ degli studi di Torino (UniTO), Torino, Italy (2) Istituto Nazionale di Fisica Nucleare (INFN), Torino, Italy

(3) Centro Nazionale di Adroterapia Oncologica, Pavia, Italy (4) Politecnico di Torino (PoliTo), Torino, Italy

Purpose. For beam monitoring in particle-therapy, silicon detectors could overcome limitations of ionization chambers. In particular, silicon sensors with internal gain (Ultra Fast Silicon Detectors, UFSDs) provide high signal-to-noise ratio and fast collection times (~1ns in 50um thickness) allowing single particle counting. Beam energy can be measured with time-of-flight techniques.

Methods. Two UFSD pads (1mm2) aligned along a proton beam are used to test UFSD counting and timing properties at therapeutic fluxes.

Results. Measurements showed well separated signals with low pile-up. Number of particles, beam flux, and crossing time were determined obtaining a time resolution ~50ps for single crossing.

Riferimenti

Documenti correlati

The results include flow patterns on the seaward and leeward side of the breakwater for both wave conditions as well as transmission and reflection

L’attestato ECM potrà essere sca ricato su ccessivam ente al corso acce den do alla pro- pria ar ea rise rvata dal se guente lin k: http://formaz ione.iz

We therefore conclude that in order to achieve a very accu- rate solution (PCG residual tolerance ∼10 −7 or better) by means of the two-level preconditioner, the Arnoldi algorithm

5, that shows the evolution of the filling factor both for local and for equilateral models, a positive primordial non-Gaussianity produces, if a scale-dependent fNL parameter

Francesco Domenico Moccia è professore ordinario di progettazione urbanistica nell’Università Federico II, coordinatore della commissione didattica del corso di laurea magistrale

Università degli Studi di Napoli Federico II Dipartimento di Giurisprudenza.. MARTEDÌ 26 GENNAIO

Five patients were treated with botulinum toxin injections (BTI), four had dilation, three received peroral endoscopic myotomy (POEM), one had POEM then dilation, and one

OBJECTIVE: We sought to evaluate the efficacy of maintenance tocolysis with vaginal progesterone compared to control (placebo or no treatment) in singleton gestations with