• Non ci sono risultati.

Displacement Based Seismic Design of Steel Moment Resisting Frames

N/A
N/A
Protected

Academic year: 2021

Condividi "Displacement Based Seismic Design of Steel Moment Resisting Frames"

Copied!
21
0
0

Testo completo

(1)
(2)

Paper

Title: Cyclic behavior of steel beam-to-column joints experimental research

Authors:

Ballio G. Calado L. De Martino A. Faella C. Mazzolani F.M.

Source Volume: Issue: Pages: Year:

Costruzioni Metalliche 2 69-90 1987

Test ID (with reference to the paper): D1

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: IPE 300

Beam

length 1185 Height: 300 Width: 150

Column Length 1 1500 Flange Thickness: 10.7 Web Thickness: 7.1 Column Length 2 1200

Root radius: Flange to

web welds:

Joint details Column

Shape: IPE300 Heigth: 300 Width: 150 Flange Thickness: 10.7 Web Thickness: 7.1

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 12

NOTE: The beam length provided is the distance between the point of application of the force and the column flange.

(3)

TestID FW1

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 314 Flange yield strength 288

Web yield strength Web yield strength 339 (mean value)

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength Yield strength

Note:

Test setup, loading protocol and test results Type of test Cyclic Type of response curve

Loading protocol ECCS [85] Force X

Data provided: Moment

Displacement X

(4)

Test ID FW2 Paper

Title: Cyclic behavior of steel beam-to-column joints experimental research

Authors:

Ballio G. Calado L. De Martino A. Faella C. Mazzolani F.M.

Source Volume: Issue: Pages: Year:

Costruzioni Metalliche 2 69-90 1987

Test ID (with reference to the paper): D2

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: IPE 300

Beam

length 1185 Height: 300 Width: 150

Column Length 1 1500 Flange Thickness: 10.7 Web Thickness: 7.1 Column Length 2 1200

Root radius: Flange to

web welds:

Joint details Column

Shape: IPE300 Heigth: 300 Width: 150 Flange Thickness: 10.7 Web Thickness: 7.1

Root radius: Flange to

web welds: Supplementary web plates X Thickness 10 Continuity plates X Thickness 12

NOTE: The beam length provided is the distance between the point of application of the force and the column flange.

(5)

Test ID FW2

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade X

Measured values X Measured values

Flange yield strength 304 Flange yield strength 235

Web yield strength Web yield strength 235

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength Yield strength

Note:

Test setup, loading protocol and test results Type of test Cyclic Type of response curve

Loading protocol ECCS [85] Force X

Data provided: Moment

Displacement X

(6)

Paper

Title: Cyclic tests of double-sided beam-to-column joints

Authors:

Dubina D. Ciutina A. Stratan A.

Source Volume: Issue: Pages: Year:

Journal of Structural Engineering 127 129-136 2001

Test ID (with reference to the paper): XS W2

Geometry

(mm)

Scheme: Interior Joint Beam

Shape: IPE 360

Beam

length 950 Height: 360 Width: 170

Beam length 2 950 Flange Thickness: 12.7 Web Thickness: 8.0 Column Length 1225

Root radius: Flange to

web welds:

Joint details Column

Shape: HEB 300 Heigth: 300 Width: 300 Flange Thickness: 18.4 Web Thickness: 11.4

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 15

NOTE: The beam length provided is the distance between the point of application of the force and the column flange. In the article, also the tensile strength and the elongation to maximum load are provided. Other information on the same test can be found in: Dubina D., Grecea D., Ciutina A., Strata, A., “Influence of Connection Typology and Loading Asymmetry”, in Moment Resistant Connections of Steel Frames in Seismic Areas, edited by F.M. Mazzolani.

(7)

TestID FW3

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 329.8 Flange yield strength 313.0 Web yield strength 348.4 Web yield strength 341.8

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values X Measured values

Yield strength 273.2 Yield strength Note:

Test setup, loading protocol and test results Type of test Cyclic/

Monotonic

Type of response curve

Loading protocol ECCS simpl. Force The moment is computed at the column face

Data provided: Moment X

Displacement Total joint

rotation

(8)

Paper

Title: Cyclic tests of doubled sided beam-to-column joints

Authors:

Dubina D. Ciutina A. Stratan A.

Source Volume: Issue: Pages: Year:

Journal of Structural Engineering 127 129-136 2001

Test ID (with reference to the paper): XU W1

Geometry

(mm)

Scheme: Interior Joint Beam

Shape: IPE 360

Beam

length 950 Height: 360.9 Width: 171.6

Beam length 2 950 Flange Thickness: 12.5 Web Thickness: 8.0 Column Length 1225

Root radius: Flange to

web welds

Joint details Column

Shape: HEB 300 Heigth: 297.7 Width: 303.4 Flange Thickness: 18.7 Web Thickness: 11.6

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 15

NOTE: The beam length provided is the distance between the point of application of the force and the column flange. In the article, also the tensile strength and the elongation to maximum load are provided. Other information on the same test can be found in: Dubina D., Grecea D., Ciutina A., Strata, A., “Influence of Connection Typology and Loading Asymmetry”, in Moment Resistant Connections of Steel Frames in Seismic Areas, edited by F.M. Mazzolani.

(9)

TestID FW4

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 329.8 Flange yield strength 313.0 Web yield strength 348.4 Web yield strength 341.8

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values X Measured values

Yield strength 273.2 Yield strength Note:

Test setup, loading protocol and test results

Type of test Type of response curve

Loading protocol ECCS simpl. Force The moment is computed at the column face

Data provided: Moment X

Displacement Total joint

rotation

(10)

Paper

Title: An Experimental Research on Beam to Column Joints: Exterior Connections

Authors:

Ballio G. Youquan C.

Source Volume: Issue: Pages: Year:

Proceedings XIV C.T.A. 110-132 1993

Test ID (with reference to the paper): E1

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: HEA 260

Beam

length 1180 Height: 250 Width: 260

Column length 1 1500 Flange Thickness: 12.5 Web Thickness: 7.5 Column Length 2 1500

Root radius: 24 Flange to

web welds

Joint details Column

Shape: HEB 300 Heigth: 300 Width: 300 Flange Thickness: 19.0 Web Thickness: 11.0

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness ?

NOTE: The beam length provided is the distance between the point of application of the force and the column flange.

(11)

TestID FW5

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values

Flange yield strength 302.0 Flange yield strength ?

Web yield strength 302.0 Web yield strength ?

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength ? Yield strength

Note:

Test setup, loading protocol and test results

Type of test Type of response curve

Loading protocol ECCS Force

Data provided: Moment X

Displacement

(12)

Paper

Title: Experimental Behavior of Beam-to-Column Welded Connections: Effect of the Panel Zone

Design Authors:

Mele E. Calado L. De Luca A.

Source Volume: Issue: Pages: Year:

Proceedings XVII C.T.A. 1999

Test ID (with reference to the paper): BCC5C

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: IPE 300

Beam

length 862 Height: 300 Width: 150

Column length 1 905 Flange Thickness: 10.7 Web Thickness: 7.1 Column Length 2 905

Root radius: Flange to

web welds

Joint details Column

Shape: HEB 160 Heigth: 160 Width: 160 Flange Thickness: 13.0 Web Thickness: 8.0

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 12

NOTE: The beam length provided is the distance between the point of application of the force and the column flange.

(13)

TestID FW6

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 274.78 Flange yield strength 323.13 Web yield strength 305.54 Web yield strength 395.56

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength Yield strength

Note:

Test setup, loading protocol and test results

Type of test Type of response curve

Loading protocol (4 different tests)

Constant amplitude (37.5mm) Constant amplitude (50.0mm) Constant amplitude (75.0mm) ECCS Force X Moment Displacement X Rotation

(14)

Paper

Title: Experimental Behavior of Beam-to-Column Welded Connections: Effect of the Panel Zone

Design Authors:

Mele E. Calado L. De Luca A.

Source Volume: Issue: Pages: Year:

Proceedings XVII C.T.A. 1999

Test ID (with reference to the paper): BCC6

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: IPE 300

Beam

length 862 Height: 300 Width: 150

Column length 1 905 Flange Thickness: 10.7 Web Thickness: 7.1 Column Length 2 905

Root radius: Flange to

web welds

Joint details Column

Shape: HEB 200 Heigth: 200 Width: 200 Flange Thickness: 15.0 Web Thickness: 9.0

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 12

NOTE: The beam length provided is the distance between the point of application of the force and the column flange. Other information on the same test can be found in: Calado L., “Influence of Column Size”, in Moment Resistant Connections of Steel Frames in Seismic Areas, edited by F.M. Mazzolani.

(15)

TestID FW7

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 278.62 Flange yield strength 312.56 Web yield strength 304.62 Web yield strength 401.62

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength Yield strength

Note:

Test setup, loading protocol and test results

Type of test Type of response curve

Loading protocol (4 different tests)

Constant amplitude (37.5mm) Constant amplitude (50.0mm) Constant amplitude (75.0mm) ECCS Force X Moment Displacement X Rotation

(16)

Paper

Title: Experimental Behavior of Beam-to-Column Welded Connections: Effect of the Panel Zone

Design Authors:

Mele E. Calado L. De Luca A.

Source Volume: Issue: Pages: Year:

Proceedings XVII C.T.A. 1999

Test ID (with reference to the paper): BCC8

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: IPE 300

Beam

length 862 Height: 300 Width: 150

Column length 1 905 Flange Thickness: 10.7 Web Thickness: 7.1 Column Length 2 905

Root radius: Flange to

web welds

Joint details Column

Shape: HEB 240 Heigth: 240 Width: 240 Flange Thickness: 17.0 Web Thickness: 10.0

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 12

NOTE: The beam length provided is the distance between the point of application of the force and the column flange. Other information on the same test can be found in: Calado L., “Influence of Column Size”, in Moment Resistant Connections of Steel Frames in Seismic Areas, edited by F.M. Mazzolani.

(17)

TestID FW8

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 292.00 Flange yield strength 300.50 Web yield strength 299.50 Web yield strength 309.00

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength Yield strength

Note:

Test setup, loading protocol and test results

Type of test Type of response curve

Loading protocol (4 different tests)

Constant amplitude (37.5mm) Constant amplitude (50.0mm) Constant amplitude (75.0mm) ECCS Force X Moment Displacement X Rotation

(18)

Test ID FW9 Paper

Title: Cyclic Behavior of Beam-to-Column Bare Steel Connections: Influence of Strain Rate

Authors:

Beg D. Plumier A. Remec C. Sanchez L.

Source Pages: Year:

Moment Resistant Connections of Steel Frames in Seismic Areas, Edited by F.M. Mazolani

167-216 2000

Test ID (with reference to the paper): SW1

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: IPE 300

Beam

length 862 Height: 300 Width: 150

Column length 1 600 Flange Thickness: 10.7 Web Thickness: 7.1 Column Length 2 600

Root radius: Flange to

web welds

Joint details Column

Shape: HEB 200 Heigth: 200 Width: 200 Flange Thickness: 15.0 Web Thickness: 9.0

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 12

NOTE: The beam length provided is the distance between the point of application of the force and the column flange. The two test are carried out with different loading frequencies.

(19)

TestID FW9

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 306 Flange yield strength 305 Web yield strength 366 Web yield strength 313

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength Yield strength

Note:

Test setup, loading protocol and test results

Type of test Type of response curve

Loading protocol Constant amplitude; Frequency 0.3 Hz Force Moment X Displacement Rotation X

(20)

Paper

Title: Cyclic Behavior of Beam-to-Column Bare Steel Connections: Influence of Strain Rate

Authors:

Beg D. Plumier A. Remec C. Sanchez L.

Source Pages: Year:

Moment Resistant Connections of Steel Frames in Seismic Areas, Edited by F.M. Mazolani

167-216 2000

Test ID (with reference to the paper): SW2

Geometry

(mm)

Scheme: Exterior Joint Beam

Shape: IPE 300

Beam

length 862 Height: 300 Width: 150

Column length 1 600 Flange Thickness: 10.7 Web Thickness: 7.1 Column Length 2 600

Root radius: Flange to

web welds

Joint details Column

Shape: HEB 200 Heigth: 200 Width: 200 Flange Thickness: 15.0 Web Thickness: 9.0

Root radius: Flange to

web welds: Supplementary web plates Thickness Continuity plates X Thickness 12

NOTE: The beam length provided is the distance between the point of application of the force and the column flange. The two test are carried out with different loading frequencies.

(21)

TestID FW10

Material Properties (MPa)

Beam Column

Nominal grade Nominal grade

Measured values X Measured values X

Flange yield strength 306 Flange yield strength 305 Web yield strength 366 Web yield strength 313

Continuity Plates Supplementary web plate

Nominal grade Nominal grade

Measured values Measured values

Yield strength Yield strength

Note:

Test setup, loading protocol and test results

Type of test Type of response curve

Loading protocol Constant amplitude; Frequency 0.3 Hz Force Moment X Displacement Rotation X

Riferimenti

Documenti correlati

- Create a matrix with the useful information of the sequences: position in the sequence of the element chosen according to cuto rule (c) and threshold rule (t), and highest element

Within this frame, studies were performed, using both resting state fMRI and task fMRI in patients with multiple sclerosis and in patients with Parkinson’s disease. We aimed at

La maggior parte degli scrittori che hanno deciso di pubblicare il proprio lavoro, hanno contattato in prima persona la casa editrice, e solamente tre su sedici sono stati

Antiprotons can spiralize around the muon beam line and then hit the target producing π 0 and then photons and fake CEs. This background can be suppressed using a magnetic selectors

Le amministrazioni centrali della Cina e degli Stati Uniti, in par- ticolare, durante il 2013, si sono osservate attentamente, prima a di- stanza e poi da vicino, durante un summit

Due to dual hydrophilic-hydrophobic behaviour, the AGaN specimen skims over the water surface (see Section 12 of the Video in Supplementary Information ) like a flying water lily

Similarly, stimulation of acrosome reaction of In summary, progesterone and A23187 elicit an increase of mammalian spermatozoa with A23187 induces an increase of PAF production

In prima istanza ad esempio basti volgere lo sguardo all’introduzione dei tatuaggi nell’ambiente malavitoso, dalla Yakuza giapponese alle bande di cen- tauri statunitensi (ed