• Non ci sono risultati.

CN and OH emissions in the 67P/Churyumov-Gerasimenko coma with Rosetta/VIRTIS-M spectrometer

N/A
N/A
Protected

Academic year: 2021

Condividi "CN and OH emissions in the 67P/Churyumov-Gerasimenko coma with Rosetta/VIRTIS-M spectrometer"

Copied!
2
0
0

Testo completo

(1)

2016 Publication Year

2020-07-17T09:29:25Z Acceptance in OA@INAF

CN and OH emissions in the 67P/Churyumov-Gerasimenko coma with Rosetta/VIRTIS-M spectrometer

Title

MIGLIORINI, Alessandra; Filacchione, G.; CAPACCIONI, FABRIZIO; PICCIONI, GIUSEPPE; Bockelee-Morvan, D.; et al.

Authors

http://hdl.handle.net/20.500.12386/26475 Handle

(2)

IASI 2016 Abstract

CN and OH emissions in the 67P/Churyumov-Gerasimenko coma with

Rosetta/VIRTIS-M spectrometer

Migliorini A.(1), Filacchione G.(1), Capaccioni F.(1), Piccioni G.(1), Bockelée-Morvan D.(2), Erard

S.(2), Leyrat C.(2), Combi M.(3), Fougere N.(3) and the Rosetta/VIRTIS Team

(1) INAF-IAPS, Istituto di Astrofisica e Planetologia Spaziali,

via del fosso del Cavaliere, 100, 00133, Rome, Italy

EMail: [email protected]

(2) LESIA, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC

Univ. Paris 06, Univ. Paris-Diderot, Sorbonne Paris Cité 5 place Jules Janssen, 92195 Meudon, France

(3) Department of Climate and Space Sciences and Engineering, University of Michigan, Ann Arbor, MI, USA

Abstract

Observations with the visible channel of the Visible and InfraRed Thermal Imaging Spectrometer (VIRTIS) on board Rosetta taken when the spacecraft was at a distance of 80-140 km from 67P/Churyumov-Gerasimenko (67P/C-G) allowed the detection of daughter gaseous species in its inner coma.

The detection of the violet doublet emission of CN at 388.3 nm has occurred during the coma monitoring campaign in November-December 2015, when the instrument has operated with long integration times (50 s) necessary to boost the instrumental SNR and detect these faint emissions.

Other features, like the C3 and C2 signatures around 420-480 nm, might possibly be visible in few

cases but with a very low intensity. For this reason, we concentrate our analysis in the spectral region from 250 to 450 nm, where the detector sensitivity allows the positive detection of the above-mentioned CN violet line at 388.3 nm, and the OH doublet emission at 309 nm. The CN emission at 388.3 nm is observed on both the day and night sides of 67P/C-G with a higher intensity on the dayside. In addition, at a preliminary analysis, the hydroxyl doublet emission intensity seems to be comparable to the violet CN line.

The same emissions were also identified in spectra acquired using ground-based facilities, when the comet had just passed the perihelion (Fitzsimmons et al., 2016).

These gaseous species emissions appear well contrasted with respect to the dust broad continuum, preferentially observed on the dayside.

Distribution and variability of the OH and CN band intensities will be discussed with respect to observation parameters.

Riferimenti

Documenti correlati

General anesthesia is of course valued for sparing patients the physical pain and psychological trauma of being sensate and conscious during surgery, but it also poses a

In this essay I aim to show how one specific bodily gland, the thyroid, and its activities complicate our established notions of narrative time and agency, and I will do so

L’at- tenzione si è quindi rivolta allo studio delle proprietà delle numerose specie di lieviti di generi diversi presenti nei mosti, detti nel loro complesso lieviti

3. Resolution-dependent neutron scattering reveals the physical nature of anhar- monic onsets. – The use of a single resolution-limited neutron spectrometer makes it impossible

— The Fermiac, known also as Fermi’s trolley or Monte Carlo trolley, is an analog computer used to determine the change in time of the neutron population in a nuclear device, via

In order to gain knowledge of the thermal behavior of the target when impinged by the primary proton beam, its temperature distribution was numerically simulated making use of the

Since the target has been designed to be used with a thin deposit of lithium and since lithium is a low-melting-point material, we have measured that, for such application, a

The MEG II tracker is a hyperbolic drift chamber (for a description see [1]), whose drift cells consist of a sense wire surrounded by 8 field wires in an approximate squared shape,