• Non ci sono risultati.

Ultrafiltration catalog

N/A
N/A
Protected

Academic year: 2022

Condividi "Ultrafiltration catalog"

Copied!
5
0
0

Testo completo

(1)
(2)

INDEX

Ultrafiltration ... 3

(3)

Ultrafiltration

Code: 08008002

Ionicore (UF) ultrafiltration filter 1/4'' OD Stem 2,5''x11'' (30)

Ultrafiltration is a system which separates water particles between reverse osmosis and microfiltration. It can be described as synthetic membrane filtration which is used to separate various macromolecules, colloids, viruses and bacteria. It operates at low pressures in comparison to reverse osmosis, almost without causing any alterations to the water mineralization. The Ionicore UF ultrafiltration membrane is produced with polysulphone capillaries, allowing water to pass from outside to inside without rejection, with nominal filtration at 0,01 microns and a maximum recommended flow of 4 lt/min. The average useful life of the system is 12.000 litres or one year, if water used is dechlorinated and with pre-filter. The recommended work pressure for the membrane is between 0,5 and 8,2 bars. The Ionicore UF ultrafiltration membrane applications are numerous, ideal for water cooler dispensers, reverse osmosis and microfiltration systems.

Ready to use, has no need of housing.

- Micron rating: 0,01 micron - Max pressure: 120psi (8,2bar) - Burst pressure: 500psi (34,4bar) - Max temperature: 113°F (45°C) - Flow rate: (1gpm) 4lt./min.

- Service life: (3.174gal.) 12.000lt.

- Dimensions DxH (mm.): 62,2x280(mm.) - 2,5”x11"(In.)

- Activation: it's advisable to run water through membrane at maximum pressure and full flow rate, for at least 5 minutes to allow air purging and flushing.

- Membrane change: When capacity is reached, or when flow comes too slow (precipitates under 0,7bar/10psi), every 12 months.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts. All systems must be maintained according to producer instructions.

Nota bene: The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water.

20 January 2021 3/5

(4)

Code: 080001

Housing and ultrafiltration (UF) membrane set and spare parts 1/4"

Variants

Code Description

080001-03 Ultrafiltration (UF) replacement membrane 080001-04 Housing wrench

Ultrafiltration is a system which separates water particles between reverse osmosis and microfiltration. It can be described as synthetic membrane filtration which is used to separate various macromolecules, colloids, viruses and bacteria. It operates at low pressures in comparison to reverse osmosis, almost without causing any alterations to the water mineralization. The MF2000 ultrafiltration membrane is produced with polysulphone capillaries, allowing water to pass from the outside to the inside without rejection, with nominal filtration between 0.1 and 0.01 microns and a maximum recommended flow of 1.5 lt/min. The average useful life of the system is 11,000 litres or one year, providing that the water used is dechlorinated and subjected to a 1-micron filtering pretreatment process. The recommended work pressure for the membrane is between 0,5 and 4 bars, and it is used as bacterial safety treatment in point-of-use equipment, such as domestic dechlorinators, fountains and post-treatment reverse osmosis systems.

Specifications

* Material: Polysulfone * Outer diameter: 460 * Inner diameter: 280 * Pressure: 0,5~4,0bar * Micron rating:

20 January 2021 4/5

(5)

Powered by TCPDF (www.tcpdf.org)

Riferimenti

Documenti correlati

Algorithms for Distributed Systems: Mid-term evaluation results Tuesday 24th of November, 2015 - Prof.

Il beamforming è un aspetto molto importante per qualsiasi sistema acustico che utilizza un array di sensori, in quanto consente di stimare al meglio il segnale proveniente da una

The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with

Vascular access Patient’s characteristics Manifacturer’s catheter design Pressure regimen Blood viscosity Blood flow Flow resistance Recirculation Hagen–Poiseuille equation

During the tests, an attempt was made to establish the operational parameters of the flocculation process (the flocculant dose and the process temperature), which contribute to

The pH of feed water affects the retention performance because of its impact on the surface properties of membrane, stability and chemical structure of BPA.. pH has an impact on the

The produced water at the end of the treatment, which is in the ultrafiltration process, met the requirements of the National Environmental Quality