• Non ci sono risultati.

“ Testing of the applicability of OUR for monitoring and operation of U S N F II

N/A
N/A
Protected

Academic year: 2021

Condividi "“ Testing of the applicability of OUR for monitoring and operation of U S N F II"

Copied!
18
0
0

Testo completo

(1)

U

NIVERSITÀ DEGLI

S

TUDI DI

N

APOLI

F

EDERICO

II

SCUOLA POLITECNICA E DELLE SCIENZE DI BASE

CORSO DI LAUREA MAGISTRALE

IN INGEGNERIA PER L’AMBIENTE E IL TERRITORIO

“Testing of the applicability of OUR for monitoring and operation of individual treatment plants”

RELATORE CANDIDATA Ch.mo Prof. Ing. Massimiliano Fabbricino Renata Mirra matr. M67/388

ANNO ACCADEMICO 2018/2019

(2)

Introduzione

• Obiettivi:

 Valutare l’applicabilità dell’OUR nel seguire

l’avanzamento di un processo a fanghi attivi in un impianto on-site;

 Valutare gli effetti dei detersivi domestici sul processo;

 Avere un’idea dell’efficienza dei processi a fanghi attivi nei sistemi on-site.

(3)

Introduzione: on-site WWTP

• Cosa sono?

• Perchè adottarli?

• Tipologie.

(4)

Introduzione: prove respirometriche

• Misura del quantitativo di ossigeno consumato dai

microrganismi nell’unità di tempo  Misura indiretta del tasso di attività microbica.

• Oxygen Uptake Rate (OUR) come parametro per lo studio dei processi a fanghi attivi;

• Come si calcola?

y = -0.1057x + 5.0487 R² = 0.945 4.5

4.6 4.7 4.8 4.9 5 5.1 5.2

0 1 2 3 4 5

DO (mg/l)

HRT (min)

OUR

OUR

(5)

Materiali e metodi: fasi

• L’esperimento è stato strutturato in 3 fasi:

1. Test su detersivi;

2. Test dell’OUR;

3. Determinazione TSS e COD.

(6)

Prima fase: test sui detersivi

• Sono stati esaminati sei differenti detersivi:

• Misure di BOD5, COD, TN e TP per ciascuno di questi.

Sample Description Dilution in water

D1 Pill for dishwasher (biodegradable)

1 pill for 20 l of water 1/16 pill for 1.25 l of water D2 Detergent for the kitchen

(biodegradable) 1/30 for 1.5 l of water D3 Detergent for the toilet

(biodegradable)

8 ml for 6 l of water 2 ml for 1.5 l of water D4 Detergent for washing machine

(biodegradable)

50ml for 20 l of water 3.75 ml for 1.5 l of water D5 Detergent for washing machine

(non-biodegradable)

20 ml for 20 l of water 1.5 ml for 1.5 l of water D6 Detergent for toilet

(non-biodegradable)

80 ml for 6 l of water 20 ml for 1.5 l of water

(7)

Seconda fase: allestimento del laboratorio

Simulare la fase di ossidazione biologica:

 Campione di fango attivo e acqua reflua prelevato dall’impianto municipale di Dupnitsa;

 Reattore di 2 l;

 Sistema di agitazione;

 Sistema di aerazione.

(8)

Seconda fase: test dell’OUR

• No substrato: una misura di OUR ogni ora;

• Aggiunta di substrato: cinque misure di OUR in un’ora.

• Studiare il comportamento dei microrganismi con misure di OUR;

• Cinque misure del DO con intervallo di un minuto;

DAY HOUR ADD OUR (mg/lmin)

22,01

09:00 0,1489 stop aeration, OUR, start aeration 10:00 0,1506 stop aeration, OUR, start aeration

11:00 X 0,269 Take 20 ml out and fill with the same amount wastewater, stop, OUR, start 11:10 0,1615 stop aeration, OUR, start aeration

11:20 0,1508 stop aeration, OUR, start aeration 11:30 0,1027 stop aeration, OUR, start aeration 11:40 0,0967 stop aeration, OUR, start aeration 11:50 0,1114 stop aeration, OUR, start aeration

12:00 0,0924 stop aeration, OUR, start aeration and then TSS (two samples of 20ml) 13:00 0,1465 stop aeration, OUR, start aeration

14:00 0,1263 stop aeration, OUR, start aeration 15:00 X 0,2815 stop aeration, OUR, start aeration

15:10 0,1453 Take 20 ml out and fill with the same amount wastewater, stop, OUR, start 15:20 0,1144 stop aeration, OUR, start aeration

15:30 0,1456 stop aeration, OUR, start aeration 15:40 0,1464 stop aeration, OUR, start aeration 15:50 0,115 stop aeration, OUR, start aeration 16:00 0,1259 stop aeration, OUR, start aeration 17:00 0,118 stop aeration, OUR, start aeration

4.5 4.6 4.7 4.8 4.9 5 5.1 5.2

0 5

DO (mg/l)

HRT (min)

(9)

Seconda fase: test dell’OUR

• Le misure di OUR sono state divise in tre step:

• Step 1: aggiunta di 20 ml di acqua reflua;

• Step 2: aggiunta di 20 ml di acqua reflua più 30 ml del detersivo D1;

• Step 3: aggiunta di 20 ml di acqua reflua più 20 ml del detersivo D3.

(10)

Terza fase: determinazione TSS e COD

• TSS: due campioni di 25 ml una volta a settimana;

• COD: tre prelievi di 10 ml

1. Prima dell’aggiunta di substrato (WW o D1);

2. Immediatamente dopo;

3. Dopo circa 20 min.

(11)

Risultati: test sui detersivi

• D1, D3 e D4 effettivamente biodegradabili;

• Solo D1 e D3 verranno utilizzati nelle successive analisi.

Sample COD

(mg/l)

TP (mg/l)

TN (mg/l)

BOD

(mg/l) COD/BOD D1

(biodegradable) 298 0.273 0.192 4.05 61 4.89 D2

(biodegradable) - 0.015 0.964 9.46 - -

D2’ 395 - - - 17 23.24

D3

(biodegradable) 180 0.112 0.018 1.39 54 3.33 D4

(biodegradable) 194 0.560 0.851 1.44 107 1.81 D5

(non-biodegradable) 1109 0.565 1.120 2.57 92 12.12 D6

(non-biodegradable) 718 1.200 0.790 13.30 1 718.00

(12)

Risultati: test dell’OUR

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35

09:00:00 12:00:00 15:00:00 18:00:00

OUR (mg/(lmin))

time (h)

OUR results after the addition of 20 ml of wastewater (WW)

17.01.19 18.01.19 21.01.19 22.01.19

WW

WW

WW WW

WW WW

(13)

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35

09:00:00 12:00:00 15:00:00 18:00:00

OUR (mg/(lmin))

time (h)

OUR results after the addition of 30 ml of detergent D1 and/or 20 ml of wastewater (WW)

23.01.19 24.01.19 25.01.19

WW WW

WW

WW+D1 WW WW+D1

Risultati: test dell’OUR

(14)

Risultati: test dell’OUR

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35

09:00:00 12:00:00 15:00:00 18:00:00

OUR (mg/(lmin))

time (h)

OUR results after the addition of 20 ml of detergent D3 and/or 20 ml of wastewater (WW)

29.01.19 30.01.19 31.01.19 01.02.19

WW WW WW

WW+D3 WW

WW

WW WW+D3

(15)

Risultati: test dell’OUR

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35

09:00:00 12:00:00 15:00:00 18:00:00

(mg/(lmin)) OUR

time (h)

OUR results after the addition of 20 ml of detergent D3 and/or 20 ml of wastewater (WW)

05.02.19 06.02.19 07.02.19 08.02.19

WW+D3

WW WW WW

(16)

Risultati: determinazione TSS e COD

• TSS

• COD

(mg/(lmin)) OUR

COD (mg/l) before the addition of wastewater 0.0623 53.5

after the addition of wastewater 0.0851 52.5 after 20 min from the addition of wastewater 0.0608 49.9 before the addition of detergent D1 0.0530 53.1 after the addition of detergent D1 0.0722 58.5 after 20 min from the addition of detergent

D1 0.0697 55.8

before the addition of wastewater 0.0567 74.5 after the addition of wastewater 0.0790 54.7 after 4 hours from the addition of wastewater 0.0589 58.1 after 1 day from the addition of wastewater 0.0804 52.9

Phase OUR step 1

OUR step 3

OUR

step 3 COD, TN and TP test Date 22.01.19 31.01.19 7.02.19 14.02.19 19.02.19 TSS (mg/l) 1670.0 1007.5 857.5 776.7 733.3

(17)

Conclusioni

• L’esperimento ha confermato la validità dell’OUR come parametro per il controllo e la gestione dei processi a fanghi attivi anche negli impianti on- site:

 L’OUR è un parametro facilmente valutabile ed in grado di fornire risultati immediati;

 Le misure di OUR hanno dimostrato un andamento correlabile al comportamento della biomassa, un incremento nella concentrazione di sostanza organica porta un incremento nell’attività microbica, quindi un più alto tasso di consumo dell’ossigeno.

• La simulazione ha mostrato la necessità di miglioramento dei sistemi on- site:

 Durante il corso dell’esperimento si sono verificati valori sempre più bassi dell’OUR, questo ha dimostrato un’inibizione della biomassa, probabilmente causata

dall’aggressività dei detersivi aggiunti;

 Delle misure di azoto totale e di fosforo totale, risultando al di fuori dei range di misura dei test effettuati, sembrano indicarne la mancata degradazione.

• Sono necessari ulteriori studi per comprendere gli effetti dei detersivi

domestici negli impianti individuali e per implementare tali impianti al fine di renderli atti anche alla rimozione dei nutrienti.

(18)

Благодаря!

Grazie!

Riferimenti

Documenti correlati

Nel Progetto, la DLT utilizzata è di tipo permissioned, basata su sistemi di registri bilaterali, in cui ogni banca rende disponibile, simultaneamente e nel continuo,

We consider two different mod- els of fluffy dust aggregates, occurring as result of ballistic particle-cluster and cluster- cluster aggregation, and a cluster with a

It is at this point that Don Bosco was asked to act as intennediary in the negotiations between Prime Minister Carnillo Cavour, through his brother Gustavo, and

To His Eminence Cardinal J.M. Farley, D.D., Archbishop of New York I beg to inform you that following Your Eminence's decision that we re- main at Columbus

Type approval reform: independent & effective enforcement at EU level 2025 CO2 targets for cars, vans and trucks. ZEV mandate as part of CO2 regulations Technology neutral Euro

Questa “Giornata europea del car sharing”, promossa nell’ ambito della Mobility Week Europea dal Ministero dell’Ambiente, da Roma Capitale e dalla Fondazione per lo

If the ultimate end of representation using perspective – and all of the classic delineation derived from it – was founded on the attempt to (re)construct – or reproduce – space

(i) each node runs the circle algorithm, (ii) once a particle on the circumference of the forming circle recognize their being in the current position, it start casting