• Non ci sono risultati.

On correct computation of confidence intervals for kinetic parameters

N/A
N/A
Protected

Academic year: 2021

Condividi "On correct computation of confidence intervals for kinetic parameters"

Copied!
2
0
0

Testo completo

(1)

LETTER TO THE EDITOR

On correct computation of confidence intervals for kinetic

parameters

Maria Pia Francescato1 , Valentina Cettolo1& Ruggero Bellio2 1 Department of Medicine, University of Udine, Udine, Italy

2 Department of Economics and Statistics, University of Udine, Udine, Italy E-mail: mariapia.francescato@uniud.it

doi: 10.14814/phy2.14180

Two papers have been recently published in Physiology Reports (Goulding et al. 2018a,b) that compare the kinetic parameters of three physiological signals during transitions in exercise intensity. The authors, using a commercial statistical software to apply the nonlinear regression technique, reported among their results also “the 95% confidence intervals (CIs) for the derived parameter estimates”. The investigated signals (oxygen uptake, heart rate, and NIRS data) were acquired with different time resolutions, that is breath-by-breath, at 1 s (1 Hz) and 0.5 s (2 Hz), respectively. Before running the nonlinear regression, the oxygen uptake data only under-went an interpolation procedure to produce second-by-second values (i.e. at 1 Hz). It should be noted, however, that this procedure was not even supported by the results reported by Benson et al. (2017), although it was sug-gested in their abstract (Francescato et al. 2017). In fact, this procedure does not add new information to the data, rather it reiterates the already available information in the newly introduced data points, invalidating the CIs obtained by the calculations (Francescato et al. 2015).

For each of the estimated parameters, the statistical packages provide directly the 95% Confidence Limits and/or provide the Asymptotic Standard Error (ASE); commonly used confidence limits and ASE are related to each other, as follows:

Lower confidence limit¼ Estimated valueð1:96  ASEÞ Upper confidence limit¼ Estimated value þ ð1:96  ASEÞ where the constant 1.96 is valid under the hypothesis that the number of degrees of freedom is greater than 30, thus the above equations hold true for the majority of the reported physiological phenomena (Bates and Watts 1988).

The ASE is calculated on the basis of the variance-co-variance matrix and is only an estimate of the uncer-tainty; independently of the information carried by each

of the considered data points, the greater is their number, the smaller the ASE will become (Francescato et al. 2014a). By applying the interpolation procedure on the oxygen uptake data, the authors considered an artificially higher number of data points, that carried “cloned” infor-mation; consequently, the obtained and reported CIs were falsely smaller. Conversely, the CIs reported for the NIRS and heart rate data were appropriate, since the native time resolution of these parameters is finest compared to the data acquisition one, and the data points were not “cloned”.

Notably, the statistical packages running the nonlinear regression are able to deal with data showing a variable time resolution, without the need of data reordered in time. As a matter of fact, it has been shown that, simply appending one after the other, the gas exchange data of the repeated transitions (“stacking”), without modifying the native time resolution, allow to obtain ASE values for the time parameters (time delay and time constant) that yield an appropriate quantification of uncertainty (Fran-cescato et al. 2014b). We believe that, to retain all the information contained in values collected with a time res-olution that changes throughout the acquisition, the “stacking” procedure is the most correct one.

References

Bates, D., and D. Watts. 1988. Nonlinear regression analysis and its applications. John Wiley & Sons, New York. Benson, A., T. S. Bowen, C. Ferguson, S. R. Murgatroyd, and

H. B. Rossiter. 2017. Data collection, handling and fitting strategies to optimize accuracy and precision of oxygen uptake kinetics estimation from breath-by-breath measurements. J. Appl. Physiol. 123:227–242. Francescato, M. P., V. Cettolo, and R. Bellio. 2014a.

Confidence intervals for the parameters estimated from simulated O2uptake kinetics: effects of different data

treatments. Exp. Physiol. 99:187–195.

ª 2019 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

This is an open access article under the terms of the Creative Commons Attribution License,

which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

(2)

Francescato, M. P., V. Cettolo, and R. Bellio. 2014b. Assembling more O2uptake responses: Is it possible to

merely stack the repeated transitions? Respir. Physiol. Neurobiol. 200:46–49.

Francescato, M. P., V. Cettolo, and R. Bellio. 2015.

Interpreting the confidence intervals of model parameters of breath-by-breath pulmonary O2uptake. Exp. Physiol.

100:475.

Francescato, M. P., V. Cettolo, and R. Bellio. 2017. Interpreting the averaging methods to estimate oxygen

uptake kinetics parameters. J. Appl. Physiol. 123: 1018–1018.

Goulding, R. P., D. M. Roche, and S. Marwood. 2018a. Elevated baseline work rate slows pulmonary oxygen uptake kinetics and decreases critical power during upright cycle exercise. Physiol. Rep. 6:e13802.

Goulding, R. P., D. M. Roche, and S. Marwood. 2018b. “Work-to-Work” exercise slows pulmonary oxygen uptake kinetics, decreases critical power, and increases W’ during supine cycling. Physiol. Rep. 6:e13916.

2019 | Vol. 7 | Iss. 14 | e14180

Riferimenti

Documenti correlati

While a general good agreement was observed between experimental data and model calculations for protons at all energies over the measured angular range, experi- mental data

12:55– 13:15 Job performance across time: Investigating trajectory classes of performance and their relationship with self efficacy and organizational tenure (M.

The quality of the present data prevents us from firmly establishing if the observed spectral variations were due to a change in the ionization state of the circumnuclear medium

We then investigate how galaxies with different stellar masses and stellar activities are distributed around the filaments and find a significant segregation, with the most massive

Using statistical samples of 30–40 galaxy clusters, it has been shown that their radio properties on the Mpc scale have a bi- modal distribution: either they host giant radio

The second section presents recent changes occurring in the tourism industry and analyzes their impact on travel decision making, while the third section outlines the

[r]

As discussed in detail in our paper [1], the accuracy of the parameters estimated applying the non-linear regression procedure is not affected by whatever data treatment is