The 1-s interpolation of breath-by-breath

O uptake data to determine kinetic

parameters: the misleading procedure

M. P. Francescato, Phone +39 0432 494336

Email [email protected] V. Cettolo,

Department of Medicine, University of Udine, P.le Kolbe 4, 33100 Udine, Italy

Received: 18 July 2019 / Accepted: 23 October 2019

Dear Editor-in-Chief,

Zignoli et al. [3] have recently published a thorough paper concerning the state of the art concepts and future directions in modelling oxygen consumption in cycling exercise. Among the “Limitations of the hand-written models”, the authors quote one of our papers [1], attributing to us a concept that had never been expressed in the cited paper and that is exactly the contrary of what is stated in the paper.

As discussed in detail in our paper [1], the accuracy of the parameters estimated applying the non-linear regression procedure is not affected by whatever data treatment is applied (from nothing to the resampling and/or the averaging of more repetitions). Conversely, the confidence interval (CI) of the parameter

2

1✉ 1 1 e.Proofing https://eproofing.springer.com/journals_v2/printpage.php?token=Oh9B... 1 di 3 28/10/2019, 15:06

(2)

estimates are sensible to the applied data treatment. In particular, by interpolating the oxygen uptake data at 1-s for kinetic analysis, no improvement of the

parameter CI is obtained, but rather the CI necessarily becomes falsely smaller compared to the correct one. This phenomenon is due to the fact that the

interpolation procedure increases the number of data points, but the already available information is only reiterated in the added data points, without introducing new information. It can be easily demonstrated that a linear interpolation on a 0.01 s-by-0.01 s basis will result in a further narrowing,

roughly by the factor , of the CI [1]; following this reasoning, the

narrowest CI would be obtained by interpolating the data on an infinitesimal-by-infinitesimal basis.

In the paper by Francescato et al. [1] we demonstrate through Monte Carlo simulations that an asymptotic CI close to the correct one is obtainable by resampling the responses at a time interval slightly longer than the average breath duration.

Narrower, but still correct, confidence intervals can be obtained only by

increasing the original information used (i.e., increasing the number of repeated trials). The simplest method to assemble together the different trials is to append the responses one after the other (“stacking” of the repeated responses); this method allows obtaining accurate estimated parameters and congruent CI when the non-linear regression technique is applied [2].

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

1. Francescato M, Cettolo V, Bellio R (2014) Confidence intervals for the parameters estimated from simulated O2 uptake kinetics: effects of different data treatments. Exp Physiol 99:187–195. https://doi.org/10.1113

/expphysiol.2013.076208

2. Francescato MP, Cettolo V, Bellio R (2014) Assembling more O uptake2

e.Proofing https://eproofing.springer.com/journals_v2/printpage.php?token=Oh9B...

(3)

responses: is it possible to merely stack the repeated transitions? Resp Physiol Neurobiol 200:46–49. https://doi.org/10.1016/j.resp.2014.06.004

3. Zignoli A, Fornasiero A, Bertolazzi E, Pellegrini B, Schena F, Biral F, Laursen PB (2019) State-of-the art concepts and future directions in

modelling oxygen consumption and lactate concentration in cycling exercise. Sport Sciences for Health. https://doi.org/10.1007/s11332-019-00557-x

e.Proofing https://eproofing.springer.com/journals_v2/printpage.php?token=Oh9B...

Riferimenti

Documenti correlati

Using Trade Microdata to Improve Trade in Value-Added Measures 193 added, and the 100 units of b generated 300 units of domestic value added (100 directly after processing the 100

Cells undergoing regulated cell death (RCD) in response to stress can prime an adaptive immune response specific for dead cell- associated antigens provided that (1) those antigens

Pathway analysis focused on these genes was carried on with KEGG tool (http://www.genome.jp/kegg/pathway.html) and is also reported in the Supplementary Tables 1 and

The survey described in part I.A provides the dependent variables used in our analyses. The independent variables came from matching a variety of data sources to these surveys’..

To approximation of the foF2 typical variations, the data for the periods without strong magnetic disturbances and seismic activity in Kamchatka were used during neural

The paper summarise the results of a large verification experiment, in which the numerical previsions obtained through a new Pyramid Tracing program are compared with

The result is the logistic regression model // based on the best set of parameters (based on the results of the // cross-validation operation). CrossValidatorModel model

zione operata mediante l’inserimento del principio del contraddittorio nella formazione della prova il quadro di riferimento costituzionale è profondamente mutato rispetto alla fase