• Non ci sono risultati.

Magnetic Resonance Imaging &#34

N/A
N/A
Protected

Academic year: 2021

Condividi "Magnetic Resonance Imaging &#34"

Copied!
2
0
0

Testo completo

(1)

Bibliografia

1. A. Macovski, J. Pauly et al. " Magnetic Resonance Imaging " The Biomedical Engineering Handbook : second ediction. Ed. Joseph D.

Bronzino, 2000

2. http://www.cis.rit.edu/htbooks/mri

3. Cynthia B. Paschal, H. Daglas Morris. “k-space in the clinic”. JMRI 2004;19:145-159

4. J. Henning. “k-space sempling strategies”. Eur. Radiol.1999; 9:1020- 1031

5. Reuben Mezrich. “A Perspective on K-Space”. Radiology 1995; 195:297- 315

6. Qing-San Xiang, R. Mark Henkelman. “k-space Description for MR Imaging of Dynamic Objects”. MRM 1993; 29:422-428

7. J. Tsao, P.Boesiger, K. P. Pruessmann. “k-t BLAST and k-t SENSE Dynamic MRI Whit High Frame Rate Exploiting Spatiotemporal Correlation”. MRM 2003; 50: 1031-1042

8. http://www.medical.philips.com/main/products/mri/technology/kt_blast/

9. M. S. Hansen, S. Kozerke, K. Pruessmann, P. Boesiger, J. Tsao. “On the Influence of Training Data Quality in k-t BLAST Reconstruction“.

MRM 2004; 52:1175-1183

106

(2)

10. S. Kozerke, J. Tsao, R.Razavi, P. Boesiger. “Accelerating Cardiac Cine 3D Imaging Using k-t BLAST”. MRM 2002; 52:19-26

11. M. S. Hansen C. Baltes, J Tsao, S. Kozerke et al. “Accelerated Fourier Encoding by Exploiting Velocity-Spatial-Temporal Correlation“

12. J. Tsao, C. Baltes, S. Kozerke, P. Boesiger, K. P. Pruessmann.

“Accelerating Cine Flow Measurement whit k-t BLAST & k-t SENSE“

13. D. B. Twieg. “The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods”. Med.

Phys. 1983; 10:610-621.

14. R. Turner, A. Howseman et al. “Functional magnetic resonance imaging of the human brain: data acquisition and analysis”. Exp. Brain Res.

1998; 123:5-12

15. M. Allegrini, G Batignani, S. Faetti. “Corso di Fisica II “ Cap. 12, 205-230

16. A. M. Howsemann, O. Josephs, G. Rees, K. J. Friston. “ Special Issues in Functional Magnetic Resonance Imaging”

17. Douglas C. Noll, Ph.D. “A Primer on MRI and Functional MRI”

18. S. J. Kisner, T. M. Talavage, J. L. Ulmer. “Testing a Model for MR Imager Noise“

19. Alle Meije Wink, Jos B. T. M. Roerdink. “Denoising Functional MR Images: A Comparison of Wavelet Denoising and Gaussian Smoothing“.

IEEE 2004; 23:374-387

107

Riferimenti

Documenti correlati

We address the following topics: appropriate choice of imaging planes and routine sequences, why and how to perform contrast-enhanced studies, and the choice of sequences, depending

Magnetic Resonance Imaging The classical technique for obtaining MR images is called spin echo.In this technique, a 90° radio frequency pulse is followed by a 180° pulse (the purpose

– immediately after the 90° pulse, a negative magnetic field gradient is applied; the spins start precessing at a position-dependant speed, dephas- ing in an “ordinate” manner with

tatus in hippocampal body; 2’, gyrus dentatus in hippocam- pal head; 3, margo denticulatus; 4, fimbria; 5, band of Giaco- mini; 6, uncal apex; 7, crural cistern; 8, posterior

Recent advances in magnetic resonance imaging and magnetic resonance spectroscopy imaging have the potential to offer better target delineation in multiple tumor sites and for

Magnetic resonance fluoroscopic images of the pelvis at rest (a), during squeeze (b), and simulated defecation (c) in a 52-year-old asymptomatic patient after filling the rectum

ventricular regional wall stress with cine magnetic resonance imaging: normal subjects versus dilated cardiomyopathy. Sechtem U, Pflugfelder PW, Gould RG et al (1987) Measurement

Monitoring the effects of neoadjuvant therapy is impor- tant to assess effectiveness of chemotherapy after initial doses, thereby determining if a specific treatment should be