• Non ci sono risultati.

Webster, “Reducing motion artifacts and interference in biopotential recording,” IEEE Transactions on Biomedical Engineering, Vol

N/A
N/A
Protected

Academic year: 2021

Condividi "Webster, “Reducing motion artifacts and interference in biopotential recording,” IEEE Transactions on Biomedical Engineering, Vol"

Copied!
2
0
0

Testo completo

(1)

Bibliografia

[1] http://www.hitech-projects.com/euprojects/myheart/

[2] R. Paradiso, G. Loriga, N. Taccini, “A Wearable Health Care System Based on Knitted Integrated Sensor,” IEEE Transactions on Information Technology in Biomedicine, Vol. 9, pp. 337-344, Sep. 2005.

[3] J. G. Webster, “Reducing motion artifacts and interference in biopotential recording,” IEEE Transactions on Biomedical Engineering, Vol. BME-31, pp.

823-826, Dec. 1984.

[4] S. Haykin, Adaptive Filter Theory, 3rd edition, Prentice Hall, 1996.

[5] P. S. Addison, “Wavelet transform and the ECG: a review,” Physiological Measurement, Vol. 26, pp. R155-199, 2005.

[6] P. S. Addison, “Using Wavelet transform for ECG Characterization: An On-Line Digital Signal Processing System,” IEEE Engineering in Medicine and Biology, Vol. 16, pp. 77-83, 1997.

[7] D. A. Tong, K. A. Bartels, K. S. Honeyager, “Adaptive Reduction of Mo- tion Artifact in the Electrocardiogram,” Proceedings of the Second Joint EMBS/BMES Conference, Vol.2, pp. 1403-1404

[8] M. A. D. Raya, L. G. Sison, “Adaptive Noise Cancelling of Motion Artifact in Stress ECG Signals Using Accelerometer,” Proceedings of the Second Joint EMBS/BMES Conference, Vol.2, pp. 1756-1757

(2)

[9] R. R. Coifman, D. L. Donoho, “Translation-Invariant De-Noising,” Lect.

Notes Statist., 103, pp. 125-150, 1995.

[10] S. Mallat, “A Theory for Multiresolution Signal Decomposition: The Wa- velet Representation,” IEEE Transactions on Pattern Analysis and Machine Intelligence, Vol. 11, pp. 674-693, Jul. 1989.

[11] S. Mallat, S. Zhong, “Characterization of Signals from Multiscale Edges,”

IEEE Transactions on Pattern Analysis and Machine Intelligence, Vol. 14, pp.

710-732, Jul. 1992.

[12] C. Li, C. Zheng, C. Tai, “Detection of ECG Characteristic Point Using Wavelet Transform,” IEEE Transactions on Biomedical Engineering, Vol. 42, pp. 21-28, Jan. 1995.

[13] http://www.physionet.org/physiobank/database

[14] J. P. Mart´ınez, R. Almeida, S. Olmos, A. P. Rocha, P. Laguna “A Wavelet-Based ECG Delineator: Evaluation on Standard Database,” IEEE Transactions on Biomedical Engineering, Vol. 51, pp. 570-581, Apr. 2004.

[15] J. Pan, W. J. Tompkins “A Real-Time QRS Detection Algorithm,” IEEE Transactions on Biomedical Engineering, Vol. BME-32, pp. 230-236, Mar. 1985.

[16] Patrick S. Hamilton, W. J. Tompkins “Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database,” IEEE Tran- sactions on Biomedical Engineering, Vol. BME-33, pp. 1157-1165, Dec.

1986.

[17] http://www.semiconductors.philips.com/pip/LPC2132FBD64.html

[18] P. A. Laplante, Real-Time Systems Design and Analysis: An Engineer’s Handbook , 3rd edition, Wiley-IEEE Press, 2004.

Riferimenti

Documenti correlati

De Gaudenzi “A High Efficiency Scheme for Quasi- Real-Time Satellite Mobile Messaging Systems ”, 10th International Workshop on Signal Processing for Space Communications,

The 9th WSEAS International Conference on Mathematical and Computational Methods in Science & Engineering (MACMESE'07, this conference was part of the MMACTEE

 Considering that this occupation has prevented the holding of the Citizen Forum of civil society and constitutes a flagrant violation of freedom of expression,

These results reflect that the approach of a treated stream recycling together with addition of hydrophilic compound considerably increase the removal efficiency of cyclohexane in the

Several patterns of joint involvement, often followed by flexion contracture, may occur in pa- tients with diabetes mellitus, including periarthritis (stiff shoulder due to

In particular, we are able to characterize mean and variance of the local estimator ˆ ad-hoc j (t) during the algorithm evolution (transient analysis) and for any fixed value of

As shown in the Figure 4, CFD results follow the experimental data contained in Hooper paper but are numerically different of those obtained through Hooper equation.. Some

“ Changes on EMG activation in healthy subjects and incomplete SCI patients following a robot-assisted locomotor training”, IEEE International Conference on Rehabilitation