Next generation HPGe segmented detector arrays will reconstruct the path of the incident

N/A
N/A
Protected

Academic year: 2021

Condividi "Next generation HPGe segmented detector arrays will reconstruct the path of the incident"

Copied!
1
0
0

Testo completo

(1)

Next generation HPGe segmented detector arrays will reconstruct the path of the incident

 ray inside the active volume of the detectors. This feature permits to identify the incident direction of the measured gamma. Consequently, it will be possible to correct for the energy shift caused by Doppler effect, recovering the intrinsic HPGe energy resolution, and to reject the background events which do not deposit their full energy inside the array or do not originate from the target position. In order to reconstruct the - ray trajectory inside the array it is necessary to determine the 3D coordinates of the -ray interaction points inside the HPGe detectors and the related energy release. The position sensitivity of the detectors is achieved by the segmentation of outer contact and by analyzing current pulse shapes of the segments (Pulse Shape Analysis). We present a simple PSA method that determines the number of interactions inside a HPGe detector segment and their radial localization. The algorithm processes only the net charge collecting segment signal, using a specific comparison procedure with a basis of reference signals. The performances obtained applying the algorithm on simulated pulse shapes range between 65 to 95% (for the right determination of both radial localization and hit numbers determination), depending on the complexity of the analyzed event. The algorithm has then been applied to data acquired during two different in-beam tests. The first performed with a 25-fold segmented HPGe detector (cylindrical crystal with 90mm length and 72mm diameter) and the other with a cluster of 3 36-fold segmented HPGe detectors (each one consisting of a 90mm long crystal with diameter of 80 mm, from the AGATA Demonstrator array). The radial and hit numbers distributions obtained following the PSA process of experimental pulse shapes are compared with those resulting from performed simulations.

Riferimenti

Documenti correlati

The source-induced background is higher for the larger detector (except in the 100 keV region), but the ratio of the two backgrounds is never as high as the efficiency ratio for

The preamplifier rise time, as measured at the test bench, is as fast as 7.5 ns, with a detector capacitance of 21 pF and with a 5 m 50 twisted-pair cable connected at its output..

between events or γ rays: this approach allows to increase by orders of magnitude the acquisition rate of signals associated to single interaction points with a determined

PSA algorithms developed for highly segmented HPGe detectors make use of a signal data base which contains the detector pulse shapes for all the possible interaction positions

Gamma ray tracking arrays composed of large volume segmented HPGe detectors like AGATA and GRETA will be used in experiments with radioactive ion beams.. The gamma

Comparing the results of RS_3D obtained with the two different bases it has been possible to evaluate the algorithm performances for interactions localization and also to check

This study represents a crucial test of the AGATA detectors for the measurement of high- energy gamma rays, in terms of detection efficiency, energy resolution, tracking and

The Pulse Shape Comparison based Scan (PSCS) method allows to decrease the time consumption needed to perform such detector characterization measurements. It has been described