+1,00
+1,00 +1,00
+5,75 +5,75
+5,25
+5,25 +5,75
+5,75 +5,75
+5,75
+9,88 +19,14
+9,88
+9,88
+9,88 +9,88
+9,88
U T A A S E Z I O N E S O V R A P P O S T A a : 1 , 6 m b : 4 , 2 m b1: 2 , 5 m c : 3 , 3 m p o r t a t a : 1 5 0 0 0 m3/ h C
b1 b1
B A
C b1
A B C
B A
b1
C
B A
b1
C
A B
U T A A S E Z I O N E S O V R A P P O S T A a : 1 , 7 m b : 4 , 4 m b1: 2 , 7 m c : 3 , 5 m p o r t a t a : 2 0 0 0 0 m3/ h
U T A A S E Z I O N E S O V R A P P O S T A a : 0 , 8 m b : 3 , 1 m b1: 1 , 3 m c : 1 , 5 m p o r t a t a : 4 0 0 0 m3/ h
U T A A S E Z I O N E S O V R A P P O S T A a : 3 , 4 m b : 5 m b1: 3 m c : 4 m p o r t a t a : 5 0 0 0 0 m3/ h
U T A A S E Z I O N E S O V R A P P O S T A a : 3 , 5 m b : 5 , 2 m b1: 3 , 4 m c : 4 , 6 m p o r t a t a : 7 0 0 0 0 m3/ h
1 2 3
5
5 1
3
3
2 2 2 2 2
2
2
2 2
2 2
2 2
2
1
1 1
1
1 5
5
5
5 5
5
4
4
4
suddivisione in aree climatiche palaghiaccio MODELLO MEP - HVAC GRUPPO UTA
F O Y E R P T F O Y E R P - 1
piano interrato piano terra piano primo
GRUPPO UTA
B A G N I S U I 3 L I V E L L I
GRUPPO UTA
S P A L T I
GRUPPO UTA
C A M P O P T
GRUPPO UTA
C A M M I N A M E N T I ( S U I 3 L I V E L L I )
GRUPPO UTA
C A M P O P - 1
GRUPPO UTA
S P O G L I A T O I P T ; P - 1 U F F I C I P T ; P - 1 D E P O S I T I I N F E R M E R I E
GRUPPO UTA
R I S T O R A N T E B A R
p-1
pt
p1
2 0 ° C
2 4 ° C 2 2 ° C
2 6 ° c
n o n c l i m a t i z z a t o i n v e r n a l e
e s t i v a
t e m p e r a t u r e d i p r o g e t t o 1 0 ° C
1 0 ° C 1 5 ° C
2 0 ° C 1 8 ° C
2 2 ° C
n . b l e q u o t e s i r i f e r i s c o n o a g l i i n t r a d o s s i d i c o p e r t u r a d e i l o c a l i
7 % 6 % 3 % 6 % 1 %
4 %
8 0 % 9 3 %
QV E N T I L A Z I O N E QP E R S O N E QL U M I N O S O QC O M P O N E N T I
QS O L A R E
c a n a l i d i p r e s a e d i s c a r i c o P O M P E
D I C A L O R E U N I T à D I
T R A T T A M E N T O D E L L ’ A R I A
M A C C H I N A F R I G O R I F E R A QV E N T I L A Z I O N E QT R A S M I T T A N Z E
QT R A S M I T T A N Z E
T O T A L E I N V E R N A L E
p o t e n z a t e r m i c a : 2 , 2 6 m w a c s ( a c q u a c a l d a s a n i t a r i a ) t o t a l e n o n d i v i s o p e r s t a g i o n i p o t e n z a t e r m i c a : 0 , 4 3 m w
T O T A L E E S T I V O
p o t e n z a t e r m i c a : 6 , 6 7 m w
c a n a l i d i
r i t o r n o c a n a l i d i m a n d a t a P o m p a d i c a l o r e i n v e r t i b i l e
( m a c c h i n a f r i g o r i f e r A E p o m p a d i c a l o r e )
“ T i p o T h e r m o c o l d H E V ” T I P O M o d . 2 6 5 0 v
F l u i d o u t i l i z z a t o : a c q u a S c a r i c o : a c q u a
P o s i z i o n a m e n t o : i n t e r n o
A : 4 0 3 5 m m B : 1 2 1 0 m m C : 1 9 2 1 m m - P o t e n z a f r i g o r i f e r a : 6 4 5 K W
- E E R : 4 , 1 9
- P o t e n z a t e r m i c a : 7 2 6 K W - C O P : 4 , 3 7
PANNELLI FOTOVOLTAICI E POSIZIONAMENTO
POMPA DI CALORE UTILIZZATA uta (unita’ trattamento dell’aria)
RAPPORTO TRA LE POTENZE TERMICHE CALCOLATE
C
B A
P a n n e l l o f o t o v o l t a i c o S I L I C I O m o n o c r i s t a l l i n o a d a l t e p r e s t a z i o n i
D i m e n s i o n i : 1 6 4 0 x 9 9 2 m m S p e s s o r e : 3 5 m m
T r a t t a m e n t o A n t i P I D
( P o t e n t i a l I n d u c e d D e g r a d a t i o n ) P o t e n z a d i P i c c o : 0 , 3 2 K W
P o t e n z a a l m2: 0 , 2 K W / m2
C O P E R T U R A U T I L I Z Z A T A 7 2 8 0 M Q
F O T O V O L T A I C O M I N I M O : 5 3 7 5 M Q < 7 2 8 0 M Q
POLITECNICO DI MILANO SCUOLA AUIC
architettura urbanistica e ingegneria delle costruzioni
CORSO DI LAUREA MAGISTRALE
“ARCHITETTURA DELLE COSTRUZIONI”
SCUOLA AUIC - a.a. 2018/2019
PROGETTO DI TESI - ARCHITETTURA DELLE COSTRUZIONI COMPLESSE ii professori: Tomaso monestiroli, vassilis mpampatsikoS,
daniele fanzini, paolo oliaro, paola gallo stampino
studenti: simone cetta 897414 davide natale 883611 andrea tolomeo 903981
tavola
impianti del palaghiaccio
sintesi del progetto impiantistico
0 m 4 m 8 m 12 m 20 m