PEGA 105X70
Sezione A/A’
Section A/A’
Sezione B/B’
Section B/B’
Vista in pianta plan view
1050 225
350
700
700
1050 70
380
450 530
250
70
290
910
70 70
440 560
45
A A’
B
B’
DATI TECNICI VASCA IN ACRILICO 105X70
ACRYLIC BATHTUB 105X70 TECHNICAL INFO
DATI TECNICI
Ingombro vasca proiettato nel muro
Bath overall dimensions as projected on the wall Inglese????????
Francese?????? Inglese????????
Francese??????
C
T CB
F
FB 150
150
350
250 225 550
700
560
1050
700
375
650 700
1050
250 S
PEGA 105X70
VASCA IN ACRILICO 105X70 VASCA IN ACRILICO 105X70 DATI TECNICI
ACRYLIC BATHTUB 105X70 TECHNICAL INFO
DATI TECNICI Inglese????????
Francese??????
I
GB
N.B. L’ISTALLAZIONE DEVE AVVENIRE A PAVIMENTO E PARETI FINITE Peso netto: Kg 18 Peso spedizione: Kg 23 Volume spedizione: m3 = 0,777 Contenuto acqua Lt 85
N.B. THE INSTALLATION MUST BE CARRIED OUT WITH FLOOR AND WALLS ALRESDY TILED Net weight: Kg 18 total weight with package: Kg 23 Volume with package: m3 = 0,777 Water capacity Lt 85
Numero jets: 0
Numero jets: 0
C : Allaccio acqua calda rubinetteria parete: 1/2”
F : Allaccio acqua fredda rubinetteria parete: 1/2”
CB : Allaccio acqua calda bordo vasca: 1/2”
FB : Allaccio acqua fredda bordo vasca: 1/2”
T : Allaccio miscelatore per erogazione da troppopieno: 1/2”
S : Allaccio scarico incassato a pavimento: 1-1/2”
C : Wall taps outlet for hot water: 1/2”
F : Wall taps outlet for cold water: 1/2”
CB : Bath edge taps outlet for hot water: 1/2”
FB : Bath edge taps outlet for cold water: 1/2”
T : Single outlet for mixed water to supply by overflowing: 1/2”
S : Drainage outlet istalled in the floor: 1-1/2”
C F : Rubinetteria parete CFT: Rubinetteria parete con erogazione troppopieno CB BF: Rubinetteria bordo vasca
C F : Wall taps CFT: Wall taps with water supply by overflowing CB BF: Bath edge taps F
CARATTERISTICHE IDRAULICHE
WATER SYSTEM
SPECIFICATION CONDITION REQUIRED BEFORE THE INSTALLATION TAPS COMBINATION REQUISITI DI PREISTALLAZIONE COMBINAZIONI
RUBINETTERIA
WATER SYSTEM
SPECIFICATION CONDITION REQUIRED BEFORE THE INSTALLATION TAPS COMBINATION N.B. THE INSTALLATION MUST BE CARRIED OUT
WITH FLOOR AND WALLS ALRESDY TILED Net weight: Kg 18 total weight with package: Kg 23 Volume with package: m3 = 0,777 Water capacity Lt 85
Numero jets: 0 C : Wall taps outlet for hot water: 1/2”
F : Wall taps outlet for cold water: 1/2”
CB : Bath edge taps outlet for hot water: 1/2”
FB : Bath edge taps outlet for cold water: 1/2”
T : Single outlet for mixed water to supply by overflowing: 1/2”
S : Drainage outlet istalled in the floor: 1-1/2”
C F : Wall taps CFT: Wall taps with water supply by overflowing CB BF: Bath edge taps
Inglese????????
Francese??????
PEGA 105X70
VASCA IN ACRILICO 105X70 VASCA IN ACRILICO 105X70 DATI TECNICI
ACRYLIC BATHTUB 105X70 TECHNICAL INFO
DATI TECNICI
PEGA 120X70
VASCA IN ACRILICO 120X70
Sezione A/A’
Section A/A’
Sezione B/B’
Section B/B’
Vista in pianta plan view
1200
225
3 5 0
7 0 0
680
2 5 0 3 8 0
1200
700
560 70
70
440 1060 70 70
290
610
4 5
A A’
B
B’
ACRYLIC BATHTUB 120X70 TECHNICAL INFO
DATI TECNICI
Ingombro vasca proiettato nel muro
Bath overall dimensions as projected on the wall VASCA IN ACRILICO 120X70
Inglese????????
Francese??????
C
T CB
F
FB 150
150
3 5 0
225 250
55 0 70 0
5 6 0
120 0
7 0 0
525
800 875
120 0
250 S
PEGA 120X70
DATI TECNICI VASCA IN ACRILICO 120X70
ACRYLIC BATHTUB 120X70 TECHNICAL INFO
DATI TECNICI Inglese????????
Francese??????
I
GB
N.B. L’ISTALLAZIONE DEVE AVVENIRE A PAVIMENTO E PARETI FINITE
Peso netto: Kg 20 Peso spedizione: Kg 25 Volume spedizione: m3 = 0,777 Contenuto acqua Lt 100
N.B. THE INSTALLATION MUST BE CARRIED OUT WITH FLOOR AND WALLS ALRESDY TILED
Net weight: Kg 20 total weight with package: Kg 25 Volume with package: m3 = 0,777 Water capacity Lt 100
Numero jets: 0
Numero jets: 0
C : Allaccio acqua calda rubinetteria parete: 1/2”
F : Allaccio acqua fredda rubinetteria parete: 1/2”
CB : Allaccio acqua calda bordo vasca: 1/2”
FB : Allaccio acqua fredda bordo vasca: 1/2”
T : Allaccio miscelatore per erogazione da troppopieno: 1/2”
S : Allaccio scarico incassato a pavimento: 1-1/2”
C : Wall taps outlet for hot water: 1/2”
F : Wall taps outlet for cold water: 1/2”
CB : Bath edge taps outlet for hot water: 1/2”
FB : Bath edge taps outlet for cold water: 1/2”
T : Single outlet for mixed water to supply by overflowing: 1/2”
S : Drainage outlet istalled in the floor: 1-1/2”
C F : Rubinetteria parete
CFT: Rubinetteria parete con erogazione troppopieno CB BF: Rubinetteria bordo vasca
C F : Wall taps
CFT: Wall taps with water supply by overflowing CB BF: Bath edge taps
F
CARATTERISTICHE IDRAULICHE
WATER SYSTEM
SPECIFICATION CONDITION REQUIRED BEFORE THE INSTALLATION TAPS COMBINATION REQUISITI DI PREISTALLAZIONE COMBINAZIONI
RUBINETTERIA
WATER SYSTEM
SPECIFICATION CONDITION REQUIRED BEFORE THE INSTALLATION TAPS COMBINATION
N.B. THE INSTALLATION MUST BE CARRIED OUT WITH FLOOR AND WALLS ALRESDY TILED
Net weight: Kg 20 total weight with package: Kg 25 Volume with package: m3 = 0,777 Water capacity Lt 100
Numero jets: 0
C : Wall taps outlet for hot water: 1/2”
F : Wall taps outlet for cold water: 1/2”
CB : Bath edge taps outlet for hot water: 1/2”
FB : Bath edge taps outlet for cold water: 1/2”
T : Single outlet for mixed water to supply by overflowing: 1/2”
S : Drainage outlet istalled in the floor: 1-1/2”
C F : Wall taps
CFT: Wall taps with water supply by overflowing CB BF: Bath edge taps