The advantageous ECG-vacuum system

The essential equipment for the streamlined modern ECG healthcare centre.

Ver 15.9.3

(2)

The advanTageous vacuum ecg sysTem

Decapus

®

III is hygienic, easy to use and time saving. The system has all the advantages that are normally associated with vacuum application, but lacks the disadvantages.

The new Decapus

®

III is designed to provide an easy to use vacuum ECG-system, with a rapid 4- level vacuum setting, simplifying adaption to skin type and examination mode.

cosT efficiency

The Decapus

®

III system is designed to save time and reduce cost for clinics by:

1) Streamlining the ECG- procedure for hospital staff. The interactive control panel and ergonomic system design makes ECG- measurements more efficient for the operator.

2) Rationalize the maintenance procedure for the service department. The computerized service and preventive maintenance practice, featuring a pdf- printable report, simplifies the workflow for service technicians. The new procedure for service and easy exchange of the robust patient cables makes it even better than before.

high power rechargeable liThium-ion baTTery

Decapus

®

III can be equipped with a Li-Ion battery which makes it completely mobile,

offering absolute freedom for the operator. The reinforced, easy exchangeable, patient

cables with high tensile strength ensure good signal quality over long periods. The system is

defibrillation protected.

(3)

Indicator for electrode change (after 10 measurements).

Button for acknowledgement of replacement.

On/off button to shut off the vacuum pump and to loosen electrodes after measurement.

4 buttons for setting desired negative pressure.

Battery operation and charging status indicator.

Mains power indicator.

Service needed indicator. Contact authorised service technician.

Marking panel for leads.

easy replaceable hygienic Quickels elecTrodes

The patented Quickels electrodes efficiently adhere to the patient, are easy to exchange and sustain a high hygienic factor equal to adhesive electrodes. It is made of non- allergic material and the electrode itself is an Ag/AgCl sensor, fulfilling recommendations of AAMI.

These features make the use of Decapus

®

III comparable to the use of adhesive electrode systems.

The mechanical design of the Quickels electrode preserves the skin/electrode interface extremely stable and creates less motion artifacts, resulting in a clear ECG trace, which is not possible by the use of conventional adhesive electrodes. This make Decapus

®

III with Quickels electrodes the best choice for a successful ECG, especially during ECG

stress- testing.

(4)

www.quickels.com

Technical data

General

environMental requireMents puMp Module

patient Module

poWer supplY

cables

patient cable quickels electrode

batterY

siGnal in/out puMp Module

stand

service application

Safety

Ambient temperature Relative humidity Air pressure Power consumption Negative pressure Airflow Measurement Weight

Defibrillation protection Rapid negative pressure selection Measurement

Weight Model

Mains voltage and frequency Current rating

AC input Classification Printer cable Control cable Vacuum hose Length Tensile resistance Material

Battery pack (option) Manufacturer Lifetime Charging Control cable input USB input DC input

Length of folding arm Table fixation Software

MDD Classification Class IIa IEC 60 601-1 class I, type CF, with defibrillation protection.

In operation: +10 to + 40°C. In storage -10 to +40°C 25-95%, no condensation

700-1060 mbar Max 35 W 0-600 mbar

7.5 litres/min at the patient end H 100 mm, L 240 mm, W 180 mm 1.1 kg

10 kOhm with surge protection 140 V 120, 200, 240, 280 mbar

H 30 mm, L 110 mm, W 135 mm 1.1 kg

XP Power Model: AFM 45US15 100-240 V, 50 or 60 Hz Max 1.1 A IEC-320-C14

Class I, according to IEC 60 601-1 2.7 m, DA-15 plug/socket 2.8 m, DE-9 plug/socket 2.8 m

Extremities: 1.2 m. Chest: 1.0 m Minimum 50 N

Ag/AgCl sensor, fulfils recommendations of AAMI.

Biocompatibility and toxicology studies in accordance with biocompatibility: In vitro cytotoxicity ISO 10993-5, Skin irritation ISO 10993-10 and Allergy ISO 10993-10.

Rechargeable Li-ion-battery 11.1 V, capacity 2.6 Ah Quickels Systems AB, Catalogue number: QN D103 Approx 400 charging cycles

Charging time approx 2 hours DE-9 socket/plug

USB B socket/plug DC plug 570/650 mm

Clamp measurement 10-130 mm Compatible with Windows XP, 7 and 8

Changes may occur without prior notice.

Pump module USB

Service application

Patient module

Riferimenti

Documenti correlati

Syntax Systems in IoT-LySa are pools of nodes (things), each hosting a shared store for internal communication, sensors and actuators, and a finite number of control processes

La mobilità della Curia pontificia nel Lazio (secoli XII-XIII), a cura di Sandro Carocci, Roma, Istituto storico italiano per il medio evo, 2003 (Nuovi Studi Storici, 61),

MoDCs from colon carcinoma patients (n = 13, 6 nonmetastatic and 7 metastatic) or normal donors (n = 6) were generated from monocytes and exposed in the presence of

If a Linux process with priority higher that the Xenomai thread arrives, it is executed by Linux. If a RT-thread with priority lower than the Xenomai thread arrives while it is

When a Xenomai thread is executed in secondary mode, the interrupt shield domain is activated. All Linux interrupts are stalled, until the Xenomai thread

As for the value of Resistance to Uniaxial Compressive Strenght, the survey refers to the results obtained by the compressive press, being it a direct test; the instrument

The prototype park is divided into different thematic areas which allow the users to experiment inusual kinds of landscape, from “ruins” of old cistern (pre-existing in the area, to

In order to avoid any technical noise contamination, a second copropagating and frequency shifted field is used to provide the error signal for the alignment and to allow the