Gli standard per la categoria 6 e i nuovi strumenti di misura
"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI
TRASMISSIVI FINO A 250 MHZ"
N E T W O R K S U P E R V I S I O N
What is Fluke Networks, Inc. today?
• A stand-alone company set apart from
Fluke Corporation in May, 2000, to create an even more tightly aligned, customer- needs driven organization
• ~ $200M in annual revenues
• Over 500 associates worldwide
• Combines the best of Fluke’s heritage for
quality and reliability with network know-
how and a strong entrepreneurial spirit
N E T W O R K S U P E R V I S I O N
What we provide
House House
House
House
House
Internet /Telephony Network
Servers
Shared Workgroup Router Remote
Office
Router
Switched Workgroup
OSP/Telecom Enterprise Networks
Copper and Fiber Structured Cabling
OSP/Telecom:
Local Loop Recovery Documentation &
Reporting DSL Qualification
Troubleshooting
Enterprise Networks:
Performance Analysis Monitoring & Troubleshooting
Reporting & Documentation Moves, Adds, & Changes
Copper & Fiber Structured Cabling:
Certification Documentation &
Reporting Inspection Troubleshooting
N E T W O R K S U P E R V I S I O N
•48 Countries
•220 Sales Professionals
•1800 Distribution Outlets
•50% of our sales come from outside the US
•75% of 2001 revenue was generated by new products introduced in 2000 and 2001
•Profitable and Growing
N E T W O R K S U P E R V I S I O N
What Does Fluke Networks Do?
We deliver
What is that supposed to mean?
N E T W O R K S U P E R V I S I O N
We offer more ways to look at your network:
Hardware Software
Physical Application
LAN WAN
Portable Distributed
N E T W O R K S U P E R V I S I O N
http://www.flukenetworks.com
N E T W O R K S U P E R V I S I O N
http://www.fluke-net.com/consultants
N E T W O R K S U P E R V I S I O N
568-A Has Changed to 568-B
ANSI/TIA/EIA 568-A-1995
568-A
ANSI/TIA/EIA 568-B-2001
=
B.1 General Reqmts
B.2 Copper
B.3 Fiber
568-B.1
=
568-B.3 568-B.2
N E T W O R K S U P E R V I S I O N
What’s going away?
• TIA/EIA TSB67
• TIA/EIA TSB72
• TIA/EIA TSB75
• TIA/EIA TSB95
• ANSI/TIA/EIA 568 A 1
• ANSI/TIA/EIA 568 A 2
• ANSI/TIA/EIA 568 A 3
• ANSI/TIA/EIA 568 A 4
• ANSI/TIA/EIA 568 A 5
• TIA/EIA/IS 729
B.1 General Reqmts
B.2 Copper
B.3 Fiber
568-B.1
568-B.3 568-B.2
N E T W O R K S U P E R V I S I O N
TIA adopts the “Permanent Link”
TIA harmonizes with ISO
The revised TIA standards
no longer specify Basic Link
N E T W O R K S U P E R V I S I O N
USER’S PATCH CORD
PATCH PANEL
HORIZONTAL CABLE
Telecom Outlet
USER’S PATCH CORD
FLOOR DISTRIBUTOR
FLOOR DISTRIBUTOR WORKWORK
AREAAREA
Channel End
Channel End
Two transitions at each end
CP
Link Definition: “Channel”
CP: Consolidation Point
N E T W O R K S U P E R V I S I O N
WORK AREA WORK AREA
Link End
HORIZONTAL CABLE
Telecom Outlet
TESTER PATCH CORD
Link End
TESTER PATCH CORD
PATCH PANEL
FLOOR DISTRIBUTOR FLOOR DISTRIBUTOR
One transition at each end
Tester patch cables max. 2 m long
Link Definition: “Basic Link”
N E T W O R K S U P E R V I S I O N
We used to test the Basic Link
The Basic Link starts and ends at the tester itself, and it includes the adapter cords
Telecommunication Room Work Area
Patch Panel 90 meter max Outlet
Includes Tester Adapter Cords
Basic Link
N E T W O R K S U P E R V I S I O N
Telecommunication Room Work Area
Patch Panel 90 meter max Outlet
Includes Tester Adapter Cords
Basic Link
But the Basic Link is obsolete
Per TIA/EIA-568-B, the Permanent Link
model replaces the Basic Link model
N E T W O R K S U P E R V I S I O N
Basic Link Weaknesses
• Developing new Cat 5e specifications revealed some new challenges
– Return Loss became a critical parameter that had not been considered before
– Stranded UTP used in patch cables (and cable tester cords) was found to be very unstable and major cause of poor Return Loss performance.
– The Basic Link definition included 4 meters of cable tester cords in the performance limits, test methods, and test results!
N E T W O R K S U P E R V I S I O N
Link End
TESTER PATCH CORD
Telecom Outlet
TESTER PATCH CORD
WORK AREA WORK AREA
Patch Panel
HORIZONTAL CABLE
FLOOR DISTRIBUTOR FLOOR DISTRIBUTOR
Test results do not include
contributions by the tester patch cables
Link End
CP
Link Definition: “Permanent Link”
CP: Consolidation Point
N E T W O R K S U P E R V I S I O N
What is a “permanent link”?
• The fixed cabling in the walls – the
“permanent” part of the building infrastructure
• The link model to be used for testing the “fixed” portion of a cabling
installation
• This excludes users’ patch cables and equipment cords
• This excludes tester adapter cords, too
N E T W O R K S U P E R V I S I O N
A detailed look at the Permanent Link
The Permanent Link is the permanent cabling, and it does not include the adapter cords
Permanent Link
Consolidation Point (optional)
Does NOT include Tester Adapter Cords
Telecommunication Room Work Area
Patch Panel
Outlet
N E T W O R K S U P E R V I S I O N
The purpose of field test
• Accurately characterize the fixed portion of the data cabling installation upon completion of the
installation
• Network equipment, patch cables and equipment cables are changed many times during the life span of the fixed portion of the cabling (the infrastructure)
• Provide guarantee that the ‘Channel’ meets the
network’s requirements by connecting good patch cords
N E T W O R K S U P E R V I S I O N
Cat 5e and Cat 6 test problems
Measured Calculated Wire map
Propagation delay Length, Delay Skew Attenuation
NEXT (pair-to-pair) PSNEXT, ACR, PSACR FEXT (pair-to-pair) ELFEXT, PSELFEXT Return Loss
There are two measured parameters that
present serious accuracy problems that are
very difficult for testers to correct
N E T W O R K S U P E R V I S I O N
Return Loss is a major challenge
Permanent Link
Measured separately from both ends, Return Loss is a measure of reflected signal
(undesirable)
The Return Loss that should be measured, which is attenuated by the link, is within the link:
(Reflections occur wherever there are changes in impedance, such as bends, twist
variations, terminations, connectors, etc.)
N E T W O R K S U P E R V I S I O N
Return Loss is a major challenge
Permanent Link
Measured separately from both ends, Return Loss is a measure of reflected signal
(undesirable)
The Return Loss that should be measured, which is attenuated by the link, is within the link:
But Return Loss in the tester’s adapter cords adds measurement error and must be eliminated
– and there is only one solution – the DSP-LIA101S!
N E T W O R K S U P E R V I S I O N
The impact of twisted-pair adapters
• Twisted-pair adapters degrade with handling and use in the field – Return Loss margin can drop significantly
• Permanent links that are good – but close to the limit – can produce false failures
• Permanent links that are very good can still yield poor test results – because
twisted-pair tester adapters contribute to Return Loss!
Use the DSP-LIA101S to PASS!
N E T W O R K S U P E R V I S I O N
Return Loss of twisted-pair adapter
0 5 10 15 20 25 30 35 40 45 50
0 50 100 150 200 250 300 350 400
CAT6 BL BL +12dB Initial 50 cyc 100 cyc 200 cyc Cable Lim
21-7*LOG(f/20) 26-12*LOG(f/100)
Basic Link BL + 12 dB
Impact of handling and “aging”- Sample 1
Frequency (MHz) Return Loss (dB)
N E T W O R K S U P E R V I S I O N
Correction for adapter cable
Test parameter Effect of tester patch cable Attenuation Stable – Corrected
Length
Propagation delay
Stable – Corrected
NEXT & FEXT High Quality patch cord (PiMF or SSTP) has
negligible crosstalk
Return Loss U np r e di cta b llll e !!
N E T W O R K S U P E R V I S I O N
Requirements for accurate Return Loss
The tester’s permanent link interface cable itself must have very good return loss
characteristics
1. Impedance very close to 100 Ω Ω Ω Ω
2. Very good Return Loss performance 3. Stability: very stable impedance
characteristic over time (after repeated
uncoiling, testing, and recoiling to pack
with tester)
N E T W O R K S U P E R V I S I O N
What is necessary for return loss Measurement?
Cable with stable properties!
Calibrate here!
Use cable with best possible return loss! Impact from return loss is reduced by the round trip insertion loss (attenuation)!
Direction of measurement
Permanent link starts
Permanent link ends
This requires a high quality interconnect!
N E T W O R K S U P E R V I S I O N
Cable w/ stable properties!
Calibrate here!
Use cable with best possible return loss!
Direction of measurement
Permanent link ends
Permanent link starts
This requires a high quality
interconnect!
Measure in opposite direction!
What is necessary for return loss Measurement?
N E T W O R K S U P E R V I S I O N
• A rugged, high-
performance link interface adapter for the DSP-4000 Series testers
• Very accurately measures the performance of an
installed twisted-pair cabling system
DSP-LIA101S Permanent Link Interface Adapter
A major improvement!
N E T W O R K S U P E R V I S I O N
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
0 50 100 150 200 250
Frequency in MHz
Measurement Accuracy in dB
Cat 6 Return Loss Accuracy– Level III
Permanent Link Level III per Standard (with adapter attached to tester)
This is what tester manufacturers try to meet!
But how accurate is the DSP-LIA101S Permanent
Link Adapter?
More Accurate
Less Accurate
Tester Baseline Level III per Standard (no adapter attached)
N E T W O R K S U P E R V I S I O N
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
0 50 100 150 200 250
Tester Baseline Level III per Standard (no adapter attached)
Frequency in MHz
Measurement Accuracy in dB
Cat 6 Return Loss Accuracy– Level III
More Accurate
Less Accurate
Permanent Link Level III per Standard (with adapter attached to tester)
This is what tester manufacturers try to meet!
DSP-4000 Series with DSP-LIA101S
Out-of-the-box, our Permanent Link Adapter solution is far more accurate than any other
tester with a twisted-pair adapter!
N E T W O R K S U P E R V I S I O N
But you can do better yet...
Field Calibration of the
Permanent Link Interface
Adapter
N E T W O R K S U P E R V I S I O N
A simple calibration of the adapter cable
This is a “Network Analyzer” Calibration.
DSP-PLCAL
Calibration Artifacts
OPEN LOAD
SHORT
• Apply a technique used in the laboratory:
one-port calibration
• The Personality Module is simply replaced
with “Calibration Artifacts”: Open, Short, and
100 Ω Ω Load Ω Ω
N E T W O R K S U P E R V I S I O N
Overview of adapter calibration process
• Main and remote units are originally calibrated
• Calibration for Return Loss can be executed by customer with DSP-PLCAL kit (optional equip.)
– A highly automated process – takes only minutes
– Cal constants are stored in the adapter Flash EPROM – The adapters must be used with the DSP-4X00 with
which they have been calibrated
Calibrate only twice a year
for “better-than-new” performance...
N E T W O R K S U P E R V I S I O N
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
0 50 100 150 200 250
Tester Baseline Level III per Standard (no adapter attached)
Frequency in MHz
Measurement Accuracy in dB
Cat 6 Return Loss Accuracy– Level III
More Accurate
Less Accurate
Permanent Link Level III per Standard (with adapter attached to tester)
This is what tester manufacturers try to meet!
DSP-4000 Series with DSP-LIA101S
This is exceptional performance!
DSP-4000 Series with DSP-LIA101S – AFTER FIELD CAL –
N E T W O R K S U P E R V I S I O N
Advantages of DSP-LIA101 with calibration
• Extend the life of the DSP-LIA101S indefinitely – Restore the measurement performance of the
adapter to better than “new”
– Any aging effect due to coiling and uncoiling is compensated
– “The last adapter you’ll ever buy”
• Increase the accuracy of the RL measurement
– Much lower probability of any “false failures”
– More accuracy = more PASS results
N E T W O R K S U P E R V I S I O N
NEXT Interoperability is a challenge
Cat 6 plugs and jacks remain proprietary designs
• The jack compensates the electrical performance of the plug NEXT performance
• Vendors have implemented unique combinations to achieve Cat 6 performance for the ‘connection’
• Many combinations from different vendors perform worse than vendor-matched components
• This is the reason for the many Cat 6 Basic Link Adapters in use
N E T W O R K S U P E R V I S I O N
The DSP-LIA101S solution for NEXT
• The Permanent Link Adapter plug is modular
• The removable 8-pin plug can be replaced with different “Personality Modules”
• You need only one adapter set
N E T W O R K S U P E R V I S I O N
What is in the Personality Module?
The location of the reference plane of calibration is as close as practically possible near the plug.
• A small circuit
board connecting to leads to the 8- pin modular plug.
• A PROM to
identify the probe tip.
N E T W O R K S U P E R V I S I O N
Personality Module interoperability matrix
• NEXT performance is excellent
• Each Personality Module covers many vendors
• Other modules are under development
• Check the website…
www.flukenetworks.com
for the latest matrix update!!
N E T W O R K S U P E R V I S I O N
Advantages of Personality Modules
• You only need one set of Link Interface Adapters: the DSP-LIA101S
• The standard module DSP-PM01 delivers Cat 6 performance with at least 10 types of Cat 6
jacks
• The modules meet all of the requirements for Cat 6 and Cat 5e (and Cat 3)
• Easy to store and carry
• A set costs only half as much as a Basic Link
Adapter set
N E T W O R K S U P E R V I S I O N
Standards for field test
Level of Performance
Applicable Standards
Cabling System to be tested
Level I and II TIA TSB-67 (*) TIA category 5
TIA TSB-95 (*) Minimum Gigabit Ethernet (TIA category 5 with RL, ELFEXT and PSELFEXT) TIA/EIA-568-A-5
TIA/EIA-568-B.2 TIA Enhanced category 5 Level IIe
IEC 61935-1 ISO/IEC 11801-2000 Class D TIA/EIA-568-B Addendum 1 TIA category 6
Level III
Rev. 1 to IEC 61935-1 ISO/IEC 11801-2000 Class E (*) These TSB documents will be obsolete with the approval of TIA-568-B
Entries in red are draft specification
N E T W O R K S U P E R V I S I O N
N E T W O R K S U P E R V I S I O N
N E T W O R K S U P E R V I S I O N
DSP-LIA101S Benefits for End-Users
• Get an accurate picture of performance of the Permanent Link configuration
– Only the cabling that is part of the infrastructure – fixed and permanent.
• Get assurance that investment in cabling
infrastructure will deliver reliable long-term service
• Add good patch cords and/or equipment cords to obtain high performance channels
• Certify the cabling installation in perfect compliance
with the new industry standard
N E T W O R K S U P E R V I S I O N
Benefits for Contractors and Installers
• Carry only one set of tester interface adapters that will last virtually indefinitely
• Save time and money by measuring NEXT and Return Loss with the accuracy of lab equipment
– Get more PASS results; reduce false failures
• If the plug is damaged, replace only a Personality Module
• Restore the performance to “better than new
condition” with a simple calibration procedure
N E T W O R K S U P E R V I S I O N
Which tests must be execute ?
Which tests must be execute ?
N E T W O R K S U P E R V I S I O N
CAT 5e / 6 Cable Certification CAT 5e / 6 Cable Certification
WIRING CLOSET WIRING CLOSET
HORIZONTAL CABLE WALL OUTLET
WORK AREA WORK AREA
PATCH PANEL
DSP-4300
Smart Remote
Just Push Test!
N E T W O R K S U P E R V I S I O N
Autotest Results
• Indication of overall pass or fail
• Summary of all tests
performed and required by the chosen standard
Push the “View Result”
button to review individual tests Remember to push “SAVE”
N E T W O R K S U P E R V I S I O N
If the tests fail Push Fault Info
Time Domain X-Talk Analyzer Automated Fault Info
Find the fault and then analyze the fault
Unique Digital Test Technology
N E T W O R K S U P E R V I S I O N
Test Results Management -- Removable Memory Card
• Utilizes standard Sandisk MMC’s
– Standard card:
16 Mbytes, 300 complete tests – Optional card:
32 Mbytes, 600 complete tests
• Separate card reader included in package -- Keep the DSP in the field, not the office!
• Eliminate the need to re-test!
Store every measurement value for every applicable test parameter with the DSP- 4300.
N E T W O R K S U P E R V I S I O N
Test Results Management -- Cable Manager
TMSoftware
• CableManager shareware allows you to quickly
and easily:
– Organize
– Merge (append) – Sort up to
5000 Reports – Find
– Edit – Export – Print
Works in Windows 95, 98, NT4.0, and Windows 2000
N E T W O R K S U P E R V I S I O N
Test Results Management -- Printed Reports
• DSP Cable Management Software supports several alternatives to provide test results information to your customer:
– Graphical color report with measured test points over full frequency range (1 - 350 Mhz) – Text format with worst case
and worst value data – Summary report which
provides a list of the cabling links tested and key
information
N E T W O R K S U P E R V I S I O N
Fiber Optic Test Adapters
• Productivity:
Automatic and Fast
• Test two fibers in a link at two wave-lengths
• Automatically calculates pass/fail limits based on fiber test standards
• Provides documented
certification of test results
N E T W O R K S U P E R V I S I O N
Fiber Test Adapters
Fiber Application Standard Sources Test Tool
Multi mode
100BaseFX 10 BaseFL FDDI
ATM
Token Ring
Demand Priority
LED 850
LED 1300 DSP-FTA420S
1000BaseSX (GbE) ATM
Fibre Channel (GbFC) VCSEL 850nm FP Laser 1310nm
DSP-FTA440S
Single mode
1000BaseLX (GbE)
Fibre Channel (GbFC) FP Laser 1310nm
FP Laser 1550nm DSP-FTA430S
NEW!
N E T W O R K S U P E R V I S I O N
DSP-FTA440S
Green Band
• VCSEL 850nm
• 1310nm Laser
DSP-FTA420S
Solid Grey
• 850 nm LED
• 1300 nm LED
DSP-FTA430S
Yellow Band
• 1310nm Laser
• 1550nm Laser
Fiber Optic Test Adapters
N E T W O R K S U P E R V I S I O N
N E T W O R K S U P E R V I S I O N
We have our eye on the future for you.
Thank you !
for more info :