• Non ci sono risultati.

COD mes 1COD mes 1

COD mes 1

7

1 ✗

CODE 1 programming entering.

To perform the programming of next codes, just set the related progressive number

Execute the programming mode of the invol-ved transmitting device. (see note 6).

Confirmation of storing of CODE 1 with musi-cal input. (3 sec.)

C O D 1 C O D 1

C O D 1 O K C O D 1 O K

Exit from programming

2 ÷ 4

1

Note 6: programming modes

TO BE PERFORMED WITH THE TELEPHONE DIALLER PREPARED ACCORDING TO ITEM

• AF53994R and AF909RS control panels. Perform a switching (from PROG to ON) by using the mechanical key.

Under this condition, the control panels transmit their code which is stored by the dialler.

Should the control panel receive the alarm signal, the dialler will start its operating cycle after a 30 s. delay ( PRE-ALARM).

The above condition allows to disable the dialler by disconnecting the control panel within 30 seconds.

• AF939R remote control. Press both the keys of the remote control. Under this condition, the remote control transmits its own code which is stored by the dialler. The remote control enables the operating cycle through the RED key and disables it through the GREEN key.

The dialler starts the transmitting cycle after a 30 s. delay (PRE-ALARM) from receiving the command.

This allows to stop the dialler, within 30 seconds, through the green key.

• AF938R remote control. Press both the keys of the remote control for 5 seconds approx.

Under this condition, the remote control transmits its own code which is stored by the dial-ler. In this case, after confirmation of the code storage, 2 beeps are emitted on pressing the keys and, after 5 seconds a sound confirmation will be emitted. The remote control enables the operating cycle of the dialler by pressing one of the two red keys.

• AF913R, AF913R, AF913R-M detectors. Connect the battery to the detector.

On suppling the detector, it transmits its own code which is stored by the dialler (in the case of storage of the AF913R door-window detector, the microswitch 3, seated on the detector, must be positioned on “OFF” to inhibit the signal of end of alarm).

The detector enables the operating cycle of the dialler by sending the alarm signal to it.

Detectors AF968R – AF913R – AF913R-M and remote controls AF938R enable the opera-ting cycle of the dialler without the possibility of stopping the cycle.

1

B) Modification of the already programmed radio code

FUNZIONI

FUNZIONI

Programming of FUNCTIONS

FUNCTION 7 entering:

programming of CODE 1 ÷ CODE 4

COD mes 1 COD mes 1

7

1 ✗

CODE 1 entering.

To perform the programming of next codes, just set the related progressive number

If “

*

” is displayed, it means that the radio code has already been programmed.

CODE 1 modification entering.

Execute the programming mode of the invol-ved transmitting device. (see note 6).

If, no code is stored through this combina-tion, the code previously stored will be can-celled after emitting 2 beeps.

Confirmation of modification of CODE 1 with sound confirmation. (3 sec.), if it is OK, on the contrary 2 beeps will be emitted.

C O D 1 C O D 1 * *

C O D 1 C O D 1

C O D 1 O K C O D 1 O K

✗ ✓

Exit from programming 1

2 ÷ 4

Function 8: storing and modification of radio codes CODE 5 ÷ CODE 8.

Jumper JP1 must be on the INST position to enter this function.

A) First storing of the radio code

FUNZIONI

FUNZIONI

Programming of FUNCTIONS

FUNCTION 8 entering:

Programming of CODE 5 ÷ CODE 8

COD mes 2 COD mes 2

8

5 ✗

CODE 5 programming entering.

To perform the programming of next codes, just set the related progressive number

Execute the programming mode of the invol-ved transmitting device. (see note 6)

Confirmation of storing of CODE 5 with sound confirmation (3 sec.)

C O D 5 C O D 5

C O D 5 O K C O D 5 O K

Exit from programming 1

6 ÷ 8

B) Modification of the already programmed radio code

FUNZIONI

FUNZIONI

Programming of FUNCTIONS

FUNCTION 8 entering:

Programming of CODE 5 ÷ CODE 8

COD mes 2 COD mes 2

8

5 ✗

CODE 5 modification entering.

Execute the programming mode of the invol-ved transmitting device. (see note 6) If, no code is stored through this combina-tion, the code previously stored will be can-celled after emitting 2 beeps.

Confirmation of modification of CODE 5 with sound confirmation. (3 sec.), if it is OK, if not 2 beeps will be emitted.

C O D 5 C O D 5

C O D 5 O K C O D 5 O K

Exit from programming.

1

C O D 5 C O D 5 * *

CODE 5 entering.

To perform the programming of next codes, just set the related progressive number

If “

*

” is displayed, it means that the radio code has already been programmed.

6 ÷ 8

Function 9: Block of the operating cycle from the keypad.

By selecting this function, it is possible to stop the dialler, during the calling operating cycle, by pressing any key from the keypad.

Jumper JP1 must be positioned on the INST position to enter this function.

Note 7:

• To enable this function choose Y, by pressing key

• To disable this function choose N, by pressing key

FUNZIONI

FUNZIONI

Programming of FUNCTIONS

Programming of the keypad block (see note 7)

Function 9 entering: block of the operating cycle in progress by pressing any key from the key-pad.

BL BL Tast Tast

tast tast y y

9

*

#

✗ Confirmation of the

programmed number through

and exit from the programming through or time-out.

INTERNAL VIEW AND CONNECTION TO THE PORTABLE TELEPHONE

Note 8: The figure shows the connection to the portable telephone which is very easy and fast; the first operation to be performed is to replace the original battery which is usually supplied with the portable telephone with the battery seated inside the dialler.

Then provide the portable telephone base with the control connector.

Tamper alarm

The enclosure is provided with a NC 50 mA/60Vdc contact (TAMPER) against the opening of the envelope and its removal.

The tamper alarm signal is not transmitted to the control panel by the dialler, however it is possible to collect the tamper alarm signal, coming from the TAMPER contact, through a connector seated on the card (see picture above), and to transmit it to the control panel by means of a detector code AF913R or AF913R-M.

1 2 3 4

5 6 7 8

9 0 #

F

INST JP1 UT

INST JP1 UT

CONNETTORE TAMPER

Battery connector

TAMPER CONNECTOR

ALARM FAULT

ON TEST RCO1 CO GAS DETECTOR

Radio PIR detector

UNITA' CENTRALE / CENTRAL UNIT AF909RS

ZONE A

PANICALARMTEC.

TAMPERSCANNERTX ON PROG.

Documenti correlati