TEST in progress indication Await 5 seconds

Telephone line TEST is positive.

Indication on for 4 sec.

Keystroke the telephone number the message for the TEST must be sent to.

MESSag 1 MESSag 1

TEST OK TEST OK

_ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _

✗ ✓

TEST / TEL TEST / TEL

Function 5: Telephone system testing

Jumper JP1 must be inserted on the left during this programming.

CONNECTION TERMINAL BOARD AND INPUT/OUTPUT DESCRIPTION Find here below the terminal numbers and their description:

Description of Inputs/outputs

The IN1 and IN2 inputs may operate in two different modes selectable through JP2.

1) JP2 inserted in the right position (as shown in the wiring diagrams): in this case the inputs are balanced, they operate on a resistance-change basis. The balancing resistance provided, to be connected to the inputs, must be 47 Kohm. Diagram 1 shows the connection to devices having output NC contacts, which are necessary for the dialler operation. When the contact is closed, the dialler is at rest, when it is open the dialler starts the calling cycle.

2) JP2 inserted in the left position: in this case the inputs are not provided with positive. This means that the dialler is at rest when positive is present (+12). Without positive, the alarm cycle will start.

IN1 and IN2 are the inputs of channel 1 and channel 2 respectively. When they are unbalanced, they start their calling cycle.

IN/BL is the block control input; if it has not started yet, it excludes the calling cycle related to channel 2 whereas, if it is still in process, it will stop it. It can be connected directly to the control panel TC terminal, in this case the dialler channel 2 which is normally dedicated to burglar systems, will be stopped as soon as the control panel is disconnected and will be on as soon as the control panel is connected.

Open collector-type C/BAT output, gives the signal of low backup battery and/or GSM battery. It Terminal n° Description

POW. SUPPLY + Positive control panel power supply or additional power supply unit POW. SUPPLY – Negative control panel power supply or additional power supply unit

IN/BL Dialler channel 2 control input block GND System negative

IN1 Channel 1 control input GND System negative

IN2 Channel 2 control input GND System negative

C/BAT Back-up battery and GSM battery (open collector) level control output GND System negative

OUT TAMPER Tampering output/NC contact OUT TAMPER Tampering output/NC contact

OUT TAMPER outputs belong to a NC contact which protects against tampering and tearing. The contact will be closed when the dialler lid is closed and its enclosure is fixed on the wall. The OUT TAMPER terminal contact will open as soon as the lid is opened or the dialler is removed with force from the wall. The OUT TAMPER terminals must be connected to the control panel tamper line As an example besides diagram 1, refer to diagrams 2 and 3 showing the connection between the dialler and the AF994 and AF997 control panels.

INTERNAL VIEW AND CONNECTION TO THE PORTABLE TELEPHONE Note: The figure shows the

connection to the por-table telephone which is very fast;

just connect the con-trol connector to the portable telephone base which will also recharge the telepho-ne battery provided.

WIRING DIAGRAMS

1) Connection to devices having NC contact outputs.

1 2 3 4

5 6 7 8

9 0 #

F

OUT

TAMPER GND C/BAT GND IN2 GND IN1 GND IN/BL ALIM+

R

+

_

R

JP2

To the tamper line

R = 47KOhm

TERMINAL BOARD

Power supply from the control panel or additional power sup-ply unit

Eventual dialler channel 2 blocking NO contact

JP2 = The input will be balanced if the jumper is in the position (right) shown in the figure.

If it is in the left position, the positive failure alarm on terminals 5 (channel 1) or 7 (channel 2) will

RETE / POWER INSERITO / ON TAMPER

ON

UNITA' CENTRALE / CENTRAL UNIT AF994

This connection can be performed also on zones A1and A2 Auxiliary indoor siren N

S

TAMPER

Anti-tampering magnetic contact cod. AF901

Flashing device connection terminal Flashing device connection terminal Power supply +

Power supply –

Anti-tampering microswitch (tamper) Anti-tampering microswitch (tamper) Positive NC siren control Positive NC flashing device control

Interrupted flashing device filament signal (towards GND)

R

TAMPERGND C/BAT GND IN2 GND IN1 GND IN/BL ALIM+

To the TAMPER LINE

R

JP2

Terminal board AF998CE R=47KOhm

Note 1: for connections related to distances higher than 30 cm, use a shielded cable (with a shield central side earthed)

Note 2: the wiring diagram reports the connection of the channel 2. It is necessary to program number 5, 6, 7, 8, using this wiring diagram (see pag. 24)

RETE / POWER INSERITO / ON TAMPER

ON

UNITA' CENTRALE / CENTRAL UNIT AF997

TAMPERGND C/BAT GND IN2 GND IN1 GND IN/BL ALIM+

JP2 To the TAMPER LINE

Terminal board AF998CE

Detector NC contacts

Detector NC contacts

Flashing device connection terminal Power supply +

Power supply –

Anti-tampering microswitch (tamper) Anti-tampering microswitch (tamper) Positive NC siren control Positive NC flashing device control

Interrupted flashing device filament signal (towards GND)

Pre-alarm signalling device cod.45381

Auxiliary indoor siren Anti-tampering magnetic

contact cod. AF901

Example of a standard detector connection. This connection can be performed also on zones A1, A2, A3, C1, C2.

BLOCCO RELÈRELAY OUT12V —(10,5…14)–– 1 2 +345 BLOCCO RELÈRELAY OUT12V —(10,5…14)––

COD. detector NC contact. (see

note 2 and page 6) AF45360

TAMPER

Note 1: for connections related to distances higher than 30 cm, use a shielded cable (with a shield central side earthed)

Note 2: the wiring diagram reports the connection of the channel 2. It is necessary to program number 5, 6, 7, 8, using this wiring diagram (see pag. 24).