• Non ci sono risultati.

Monitoring of a therapeutic proton beam: preliminary tests of innovative thin silicon detectors.

N/A
N/A
Protected

Academic year: 2021

Condividi "Monitoring of a therapeutic proton beam: preliminary tests of innovative thin silicon detectors."

Copied!
2
0
0

Testo completo

(1)

21 July 2021

AperTO - Archivio Istituzionale Open Access dell'Università di Torino

Original Citation:

Monitoring of a therapeutic proton beam: preliminary tests of innovative thin silicon detectors.

Terms of use: Open Access

(Article begins on next page)

Anyone can freely access the full text of works made available as "Open Access". Works made available under a Creative Commons license can be used according to the terms and conditions of said license. Use of all other works requires consent of the right holder (author or publisher) if not exempted from copyright protection by the applicable law. Availability:

This is the author's manuscript

(2)

Title:

Monitoring of a therapeutic proton beam: preliminary tests of innovative thin silicon

detectors.

Purpose. For on-line monitoring of the prescribed dose in particle-therapy with active beam scanning, new silicon detectors could overcome the limits of ionization chambers (such as response dependence on beam energy, slow collection time, reduced sensitivity).

Based on limited internal charge multiplication, Low-Gain Avalanche Detectors (LGADs) provide high signal-to-noise ratio and fast collection time in small thickness (1 ns in 50 um), allowing direct single particle counting at high rates, if properly segmented. LGADs optimized for excellent time resolutions (Ultra Fast Silicon Detectors, UFSDs) can also measure the beam energy using time-of-flight techniques. The preliminary tests of UFSD sensors on therapeutic beams are presented. Methods. Particle fluxes and time resolutions are preliminarily evaluated using two UFSD pads (1,2 x 1,2 mm2 x 50 mm) aligned along the proton beam (intensity= 109 p/s, FWHM=1 cm). Based on the

results, dedicated UFSDs for beam monitoring are being designed and produced, together with custom VLSI chips for the readout. Different doping possibilities will be investigated to extend the radiation resistance of the sensors.

Results. The sensors signals show well separated contributions from single particles, with low pile-up probability pile-up to almost 109 p/(cm2*s). Number of particles, beam flux, and crossing time are

determined via offline analysis of collected waveforms. The obtained time resolution is 70 ps for single crossing, thus allowing precise beam energy measurements within few mm of data taking, using the timing difference between two sensors at a mutual distance < 1 meter. The measured numbers of counts from two aligned detectors are very well correlated, and the beam structure is resolved at the nanosecond level.

Conclusion. UFSDs are demonstrated to be suitable for on-line monitoring of therapeutic proton beams, by directly counting the number of particles. This information will improve the indirect measurements provided nowadays by ionization chambers.

Riferimenti

Documenti correlati

To the best of our knowledge, the only branching-time context-free logic introduced in the literature with a decidable VPMC problem (in particular, the problem is Exptime-complete)

L’attestato ECM potrà essere sca ricato su ccessivam ente al corso acce den do alla pro- pria ar ea rise rvata dal se guente lin k: http://formaz ione.iz

We therefore conclude that in order to achieve a very accu- rate solution (PCG residual tolerance ∼10 −7 or better) by means of the two-level preconditioner, the Arnoldi algorithm

5, that shows the evolution of the filling factor both for local and for equilateral models, a positive primordial non-Gaussianity produces, if a scale-dependent fNL parameter

Francesco Domenico Moccia è professore ordinario di progettazione urbanistica nell’Università Federico II, coordinatore della commissione didattica del corso di laurea magistrale

Università degli Studi di Napoli Federico II Dipartimento di Giurisprudenza.. MARTEDÌ 26 GENNAIO

Five patients were treated with botulinum toxin injections (BTI), four had dilation, three received peroral endoscopic myotomy (POEM), one had POEM then dilation, and one

OBJECTIVE: We sought to evaluate the efficacy of maintenance tocolysis with vaginal progesterone compared to control (placebo or no treatment) in singleton gestations with