• Non ci sono risultati.

A comparison of hexaminolaevulinate (hexvix®) fluorescence cystoscopy and white light cystoscopy for the detection of bladder cancer: Results of the HeRo observational study

N/A
N/A
Protected

Academic year: 2021

Condividi "A comparison of hexaminolaevulinate (hexvix®) fluorescence cystoscopy and white light cystoscopy for the detection of bladder cancer: Results of the HeRo observational study"

Copied!
2
0
0

Testo completo

(1)

Lapini A.1, Minervini A.1, Masala A.2, Schips L.3, Pycha A.4, Cindolo L.3, Giannella R.2, Martini T.4, Vittori G.1, Zani D.5, Bellomo F.6, Cosciani Cunico S.5

1University of Florence, Dept. of Urology, Florence, Italy, 2A.O.R.N. “A. Cardarelli”, Dept. of Urology, Naples, Italy, 3S. Pio Da Pietrelcina Hospital, Dept. of Urology, Vasto, Italy, 4Central Hospital of Bolzano, Dept. of Urology, Bolzano, Italy, 5University of Brescia, Dept. of Urology, Brescia, Italy, 6GE Healthcare, Milan, Italy

INTRODUCTION & OBJECTIVES: To evaluate the diagnostic accuracy of hexylaminolaevulinate (HAL) hydrochloride

(Hexvix ®) PDD cystoscopy compared with standard white light cystoscopy in an observational, open-label, comparative, controlled (within patient), multicenter study that used this diagnostic tool on a regular basis in daily practice. Sensitivity, specificity, positive predictive value and negative predictive value with each method were calculated.

MATERIAL & METHODS: Between January 2010 and January 2011, 96 consecutive patients with suspected or

confirmed bladder cancer were recruited for the HeRo observational, open-label, comparative, controlled (within patient) study done at 5 centers in Italy.

All patients had standard white light (WLC) followed by blue light cystoscopy (BLC). The presence and the number of positive lesions/suspicious areas compared to surrounding urothelium detected using WLC and BLC were recorded. Biopsies/resection of each positive lesion/suspicious areas were always taken after the bladder was inspected under WLC and BLC.

RESULTS: Overall, 234 suspicious lesions were detected in 96 patients; 108 (46.2%) were histologically confirmed to

be bladder tumors/CIS. The sensitivity of BLC biopsies was significantly higher than for WLC technique (p<0.00001; 99.1% vs. 76.8%; Delta% 22.3; McNemar Test χ2 20.346). The relative sensitivity of BLC versus WLC was 1.289 (CI 1.164-1.415) showing a superiority of BLC of 28.9% (CI 95% 16.4%-41.5%). The specificity of BLC biopsies was not significantly different compared to WLC (p=0.445; 36.5% vs. 30.2%; Delta% -6.3; McNemar Test χ2 0.583). Positive predictive value per biopsy for BLC- and WLC- guided biopsies was 54.9% and 50.9%, respectively. Negative predictive value per biopsy for BLC- and WLC- guided biopsies was 97.4% and 64.8%, respectively. The false positive biopsy rate for BLC- and WLC- guided biopsies was 45.1% and 49.1%, respectively. The sequential design analysis shows that in 83 patients the correct diagnosis was reached both by WLC and by BLC. At contrary the correct diagnosis was reached by BLC alone and WLC alone, in 11 patients (11.5%) and in 2 patients (2%) respectively. Therefore BLC and WLC reached the correct diagnosis in 97.9% and in 88.5%, respectively. This difference was statistically significant (P=0.0265; Delta % 9.4; CI 95% 1.1- 17.7).

592

A comparison of hexaminolaevulinate (hexvix®) fluorescence

cystoscopy and white light cystoscopy for the detection of bladder

cancer: Results of the HeRo observational study

(2)

CONCLUSIONS: HAL hydrochloride PDD cystoscopy used on a regular basis in daily practice enhances the

diagnostic accuracy of standard cystoscopy with an elevate negative predictive value for BLC compared to WLC permitting an improvement in patient prognosis.

Riferimenti

Documenti correlati

The thermoeconomic theory not only allows to assess the irreversibility costs to the component that has produced them, moreover is used to perform diagnosis of

identi…ed through a set of questions that attempt to de…ne religious openness; the relevance of religion in an individual’s life; religious intensity; as well re- ligious a¢

Come sottolinea Maffei, e segnala anche Garzone nelle pagine precedenti, il mediatore culturale è una figura professionale ancora indefinita, e se la legge Turco-Napolitano

The following selection criteria were used: patients aged between 18 and 80 years; FI onset at least 6 months previ- ously; faecal incontinence episodes (soiling or incontinence

The best points selected with the learning criteria described in Step D are used to compare to a stopping condition. The stopping condition is very simple: if the number of data

While XRPD data show that talc and calcined biogenic hydroxyapatite mixtures were used in 606. most cases, FT-IR/Raman techniques seldom evidence contextual presence of both these

Patients were excluded from the study if they were pregnant or nursing; had known optic nerve damage or significant peripheral nerve damage unrelated to linezolid; had a

In a cohort of lung transplanted patients who received a combined CMV prophylaxis scheme we aimed to: (a) evaluate the potential use of a CMV ELISPOT assay to identify patients