Traceability and on-site calibration for permafrost temperature sensors

N/A
N/A
Protected

Academic year: 2021

Condividi "Traceability and on-site calibration for permafrost temperature sensors"

Copied!
2
0
0

Testo completo

(1)

23 July 2021

AperTO - Archivio Istituzionale Open Access dell'Università di Torino

Original Citation:

Traceability and on-site calibration for permafrost temperature sensors

Terms of use: Open Access

(Article begins on next page)

Anyone can freely access the full text of works made available as "Open Access". Works made available under a Creative Commons license can be used according to the terms and conditions of said license. Use of all other works requires consent of the right holder (author or publisher) if not exempted from copyright protection by the applicable law. Availability:

This is the author's manuscript

(2)

Topic T9.6 Thermal metrology for meteorology and climate

Oral or Poster Presentation Oral

TRACEABILITY AND ON-SITE CALIBRATION FOR PERMAFROST

TEMPERATURE SENSORS

Francesca Sanna1, 3,*, Luca Paro2, Laura Massano3, Graziano Coppa1, Chiara Musacchio1, Andrea Merlone1

1 Istituto Nazionale di Ricerca Metrologica (INRiM), Torino (Italy) 2

Agenzia Regionale protezione ambiente (ARPA) Piemonte, Torino (Italy) 3

Università degli studi di Torino, Torino (Italy)

*

E-mail ([email protected]):

Permafrost is a key component of the cryosphere through its influence on energy exchanges, hydrological processes, natural hazards, carbon dioxide and methane emissions and the global climate system. Its degradation is seen as a major challenge in the current discussion of global warming (IPCC, 2013), due to the possible effects on climate. On these basis, accurate measurements of the permafrost properties and improved data quality in the evaluation of permafrost temperature profiles become fundamental aspects for achieving more reliable knowledge on the evolution of this component of the cryosphere.

The Sommeiller Pass permafrost monitoring station, at about 3000 m of altitude, is the key site of the regional network installed in 2009 during the European Project “Permanet” in the Piedmont Alps (NW Italy). The station consists of 3 vertical boreholes of 5, 10 and 100 m depth, equipped with thermometric chains for a total of 36 temperature sensors (thermistors type). The collected data shows a constant active layer 8-9 m of thickness, while the permafrost temperature curves show a degradation of the base at approximately 60 m of depth since 2014. In order to verify this variation (about 0.25 °C), considering the station history, sensor calibration campaigns were carried out both in laboratory and on-site aimed to understand the reliability of the measurements in progress. The accurate determination of the permafrost temperature in deep holes (100 m) will improve knowledge on ancient permafrost for climate and paleoclimate considerations. A dedicated calibration procedure was adopted and the calibration results were used in order to adjust the Sommeiller Pass permafrost monitoring station database and permafrost profiles. The permafrost temperature profiles obtained with the data to which the calibration curve was applied, reported a potential thawing of permafrost starting from 2012 at a depth of about 60 m, while a potential melting is indicated by the profile to which the calibration curve was not applied only from 2014 onwards but at the depth of 79.9 m, with a difference in the temperature value equal to 0.063 °C, annual average.

This study showed the advantage of the joint collaboration between metrology and the community working in cryosphere observations. A need emerged to discuss and agree on common approaches, best practice and uncertainty evaluation on the numerous measurements made in glacial and periglacial areas. Accuracy and data quality are a key aspect for comparability of observations from different stations taking parts in networks and among different networks. Calibration of instruments and sensors becomes then a fundamental aspect of measurement procedures to achieve full traceability of results and evaluate measurement uncertainty.

Riferimenti

Documenti correlati

Rock Glacier - Gran Sometta Slope - Cime Bianche Rock Walls - Matterhorn..

Cime Bianche: acceleration of permafrost degradation with no consequences for human activities.. RG velocities: sensible increase with potential risk for humans

bastarda nelle due integrazioni marginali ai ff. h, et nota tachigrafica, a) si rileva infatti tra la scrittura del miracolo di s. Paolo e quella delle due aggiunte. La distanza tra

Inoue M, Ogihara M, Hanada R, Furuyama N (2011) “Gestural cue analysis in automated semantic miscommunication annotation, ” Multimedia Tools and Applications (MTAP), Online

This paper presents the results of a comprehensive study of the osmotic method looking at the long-term response of three different types of membranes, the effect of temperature,

b) esibizione, da parte del cliente, di una confezione inutilizzabile, ad esempio un flaconcino danneggiato. In aggiunta alle ipotesi disciplinate negli articoli 2 e 3, il

Appena sette anni dopo la prima pubblicazione di Es liegt ei- ne Krone im tiefen Raum sull’organo ufficiale della NSDAP, i nazisti prendevano il potere in Germania e instauravano

For the 3D U(1) theory, Polyakov [ 8 ] presented an argument for the existence of a mapping between gauge and string degrees of freedom, and suggested the form of the action