• Non ci sono risultati.

Noise and vibration control in multiplex cinemas

N/A
N/A
Protected

Academic year: 2021

Condividi "Noise and vibration control in multiplex cinemas"

Copied!
1
0
0

Testo completo

(1)

paper ID: 516-IP/p.1

Noise and vibration control in multiplex cinemas

Angelo Farina

a

, Patrizio Fausti

b

a

Department of Industrial Engineering, University of Parma, Parco Area dell Scienze 181/A, 43100 Parma, Italy

b

Department of Engineering, University of Ferrara, Via Saragat 1, 44100 Ferrara, Italy

Abstract

Noise and vibration control requirements for multiplex cinemas are normally very strict. Inside the rooms, low background noise and vibration levels below the perception threshold need to be guaranteed. The noise and vibration sources could be external (road, rail and air traffic) and/or internal (adjacent cinema rooms, escalators, car parks, air conditioning plants, people in public areas). Every possible source needs to be considered in order to reduce the noise and vibration generated and transmitted through the building. In the paper an example of noise and vibration control design and verification is presented. The prescriptions of the company were very strict due to the particular environment in which the building was designed: a few meters from the railway and close to Genoa Airport, the industrial area and the dock area.

The manuscript was not received at the time of printing the CD-ROM Proceedings

authors sessions home

Riferimenti

Documenti correlati

Figure 6.16: Measured Base Impedance FRF (amplitude in the upper plot, phase in the central plot and coherence in the lower plot) of the electro-magnetic transducer in open-

Figure 3 Geely’’s trajectory of growth Catching up trajectory Multinational growthtrajectory Technology imitation Reverse engineering Product architecture innovation

In this work, a model for the spray wall interaction has been implemented, capable of describing the full range of interactions between the spray and the walls, and the formation

In addition road traffic noise monitoring has been carried out for an entire week in eighteen different sites, representative of different urban configurations, where

z The Italian Law requires that the noise produced by steady-state equipment (HVAC) has an A-weighted equivalent level less than 35 dB(A) (L A,eq < 35 dBA). z The UCI

In order to segment the Italian extra-virgin olive oil market, the information obtained from a nationwide survey was analysed by using a randomised parameter logit

codificazione e modernizzazione del diritto amministrativo, in Riv.. amministrativo e, forse, in questo caso, il linguaggio, il protocollo, diventa organizzazione