• Non ci sono risultati.

"Ultrasonics and selected physical properties of bone.&#34

N/A
N/A
Protected

Academic year: 2021

Condividi ""Ultrasonics and selected physical properties of bone.&#34"

Copied!
8
0
0

Testo completo

(1)

BIBLIOGRAFIA

1. Abendschein W. and Hyatt G.W. (1970). "Ultrasonics and selected physical properties of bone." Clinical Orthopaedics and Related Research 69: 294-301.

2. ANSYS theory reference Manual. 5.6-5.7-6.1. SAS IP Inc., Ed. (1999-2001).

3. Baleani M., Cristofolini L., Toni A., 2000. Initial stability of a new hybrid fixation hip stem: experimental measurement under torsional load in comparison with cemented and cementless stems. Journal of Biomedical Materials Research 50, 605-615.

4. Bergmann G. ((ed.), 2001). HIP98 - Loading of the hip joint. Free University, Berlin.

5. Bergmann G., Graichen F., et al. (1993). "Hip joint loading during walking and running, measured in two patients." J Biomech 26(8): 969-90.

6. Bernakiewicz M. and Viceconti M. (2002). "The role of parameter identification in finite element contact analyses with reference to orthopaedic biomechanics applications." J Biomech 35(1): 61-7.

7. Boissonnat J.-D. and Geiger B. (1993). "Three dimensional reconstruction of complex shapes based on the Delaunay triangulation." Biomedical Image Processing and Biomedical Visualisation, R. S. Acharya and D. B. Goldgof, eds., SPIE, 964-975.

8. Brown T.D. and Ferguson A. B. Jr (1980). "Mechanical property distributions in the cancellous bone of the human proximal femur." Acta Orthopaedica Scandinavica 51(3): 429-37.

(2)

9. Burke D.W. and O'Connor D.O. et al. (1991). "Micromotion of cemented and uncemented femoral components." J Bone Joint Surg [Br] 73(1): 33-7.

10. Carmignani C (1991-1992). "Introduzione al metodo degli elementi finiti. "

Dispense per il corso di Costruzione di macchine, Facoltà di Ingegneria dell’Università di Pisa.

11. Carter D. R. and Hayes W. C. (1977). "The compressive behavior of bone as a two-phase porous structure." J Bone Joint Surg Am 59(7): 954-62.

12. Carter D. R., Schwab G. H. et al., (1980). "Tensile fracture of cancellous bone." Acta Orthop Scand 51(5): 733-41.

13. Cesari F. (1989). Introduzione al Metodo degli Elementi Finiti, Pitagora.

14. Cheal E.J., Spector M. et al. (1992). "Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty." J Orthop Res 10(3): 405-22.

15. Ciarelli M.J., Goldstein S.A. et al. (1991). "Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography." Journal of Orthopaedic Research 9(5): 674-82.

16. Cook R., Malkus D.S. et al. (1989). Concepts and applications of Finite Elemnt Analysis, John Wiley & Sons Inc.

17. Dalton J.E., Cook S.D. et al. (1995). "The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants." J Bone Joint Surg [Am] 77: 97-110.

18. Duda G. N., Heller M. et al. (1998). "Influence of muscle forces on femoral strain distribution." J Biomech 31(9): 841-6.

(3)

19. Engh C.A., O’Connor D. et al. (1992). "Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses." Clinical Orthopaedics and Related Research(285): 13-29.

20. Harman M.K., Toni A., Cristofolini L., Viceconti M. (1995). “Initial stability of uncemented hip stems: an in-vitro protocol to measure torsional interface motion”. Med. Eng. Phys., 1995. Vol.17, 163-171.

21. Heller M. O., Bergmann G. et al. (2001). "Musculo-skeletal loading conditions at the hip during walking and stair climbing." J Biomech 34(7): 883- 93.

22. Henwood D. and Bonet J. (1996). Finite Elements-a gentle introduction, MACMILLAN PRESS LTD.

23. Huiskes R., Janssen J.D. et al. (1981). "A detail comparision of experimental and theoretical stress-analyses of a human femur." Mechanical Proprieties of Bone 45: 211-234.

24. Huiskes R., Verdonschot N. et al. (1998). "Migration, stem shape, and surface finish in cemented total hip arthroplasty." Clin Orthop Oct(355): 103-12.

25. Jasty M., Burke D. et al. (1992). "Biomechanics of cemented and cementless prostheses." Chir Organi Mov 77(4): 349-58.

26. Jasty M., Bragdon C.R. et al. (1996). "Differences in stifness of the interface between a cementless porous implant and cancellanous bone in vivo dogs due to varying amounts of implant motion." J Arthroplasty 11(8): 945-951.

27. Jasty M., Ramamurti B. et al. (1997). "Factors influencing stability at hte interface between a porous surface and cancellanous bone: a finite element analysis of a canine in vivo micromotion experiment." J Biomed Mater Res

(4)

28. Kang Y. K., Park H. C. et al. (1993). "Three dimensional shape reconstruction and finite element analysis of femur before and after the cementless type of total hip replacement." J Biomed Eng 15(6): 497-504.

29. Katz J.L. and Meunier A. (1987). "The elastic anisotropy of bone." Journal of Biomechanics 20(11-12): 1063-70.

30. Keaveny T. M. and Bartel D. L. (1993). "Effects of porous coating, with and without collar support, on early relative motion for a cementless hip prosthesis." J Biomech 26(12): 1355-68.

31. Knauss P. (1981a). "Material properties and strengh behaviour of spongy bone tissue at the coxal human femur." Biomedical Technology 26: 200-210.

32. Lotz J.C., Gerhart T.N. et al. (1990). "Mechanical properties of trabecular bone from the proximal femur: a quantitative CT study." Journal of Computer Assisted Tomography 14(1): 107-14.

33. Lotz J.C., Gerhart T.N. et al. (1991). "Mechanical properties of metaphyseal bone in the proximal femur." Journal of Biomechanics 24(5): 317-29.

34. Maloney W.J. and Burke D.W. (1989). "Biomechanics of femoral total hip components in simulated stair climbing." Clin. Orthop. 229.

35. Manens E., Arancione V. et al. (1996). Incidenza delle revisioni dopo 20 anni. Attualità e prospettive nella protesi d'anca, Roma.

36. Markolf K.,36 L., Amstutz H. C. et al. (1980). "The effect of calcar contact on femoral component micromovement. A mechanical study." J Bone Joint Surg Am 62(8): 1315-23.

(5)

37. Martens M., Van Audekercke R. et al. (1983). "The mechanical characteristics of cancellous bone at the upper femoral region." Journal of Biomechanics 16(12): 971-83.

38. Martini F.H., Timmons M.J., McKinley M.P. (2000). "Anatomia umana."

Edises s.r.l. – Napoli.

39. Mc Kellop H., Ebramzadeh J., Niederer P.G., Sarmiento A. (1991).

Comparicson of the stability of press-fit hip prothesis femoral stems using a synthetic model femur. Journal Orthop. Res. 9, 297-305.

40. Muccini R., Baleani M., Viceconti M. (2000). “Selection of the best element type in the finite element analisys of hip prostheses.” J. Med. Eng. Technol.

24(4): 145-8.

41. NAFEMS (1992). NAFEMS How to choose a Finite Element Pre&Post processor. NAFEMS.

42. NHI, 1982. Total Hip Joint Replacement. NHI Consens Statement 4, 1-11.

43. Otani T., Whiteside L.A. (1992). Failure of cementless fixation of the femoral component in total hip arthroplasty. Orthop. Clin. NA. 23, 335-346.

44. Ozeki K., Yuhta T. et al. (2001). "Push-out strengh of hydroxyapatite coated by sputtering technique in bone." Biomed. Mater Eng 11(1): 63-68.

45. Pasqualino A., Nesci E. (1980). "Anatomia umana fondamentale." UTET.

46. Pilliar R.M., Lee J.M., et al. (1985). "Observations on the effect of movement on bene ingrowth into porous-surfaced implants." Clin. Orthop. and related research, 55: 108-113.

(6)

47. Pilliar R.M., Simmons C.A. et al. (2001). "Mechanical regulation of localized and appositional bone formation around bone-interfacing implants." Journal Biomedical material research 55: 63-71.

48. Polgar K., Viceconti M., O’Connor JJ. (2001). “A comparison between automatically generated linear and parabolic tetrahedra when used to mesh a human femur.” Proc. Inst. Mech. Engh. 215(1): 85-94.

49. Ramaniraka N.A., Leyvraz P.F. et al. (1996). "Micromotion at the bone- implant interface during the gait cycle after cementless total hip replacement:

influence of stem design and loading level." Hip International 6(2): 51-58.

50. Reilly D.T., Burstein A.H. et al. (1974). "The elastic modulus for bone."

Journal of Biomechanics 7(3): 271-5.

51. Reilly D.T. and Burstein A.H. (1975). "The elastic and ultimate properties of compact bone tissue." Journal of Biomechanics 8(6): 393-405.

52. Rohlmann A., Mossner U. et al. (1983). "Finite element analysis and experimental investigation in a femur with hip endoprosthesis." Journal of Biomechanics 16: 727-742.

53. Schneider E., Eulenberger J. et al. (1989). "Experimental method for the in vitro testing of the initial stability of cementless hip prostheses." Journal of Biomechanics 22(6-7): 735-744.

54. Skripitz R. and Aspenberg P. (1999). "Attachment of PMMA cement to bone:

force measurements in rats." Biomaterials 20(4): 351-356.

55. Søballe K., Hansen E.S. et al. (1991). "Gap healing enhanced by hydroxyapatite coating in dogs." Clin Orthop: 300-307.

(7)

56. Søballe K., Hansen E.S. et al. (1991). "Fixation of titanium and hydroxyapatite-coated implants in arthritic osteopenic bone." J Arthroplasty 6:

307-316.

57. Søballe K., Brockstedt_Rasmussen H. et al. (1992). "Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs."

Acta Orthopaedica Scandinavica 63(2): 128-40.

58. Søballe K., Hansen E.S. et al. (1992). "Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions." J Orthop Res 10: 285-299.

59. Søballe K., Hansen E.S. et al. (1993). "Hydroxyapatite coating converts fibrous tissue to bone around loaded implants." Journal of Bone and Joint Surgery. British Volume 75(2): 270-8.

60. Søballe K., Hansen E.S. et al. (1994). "Hydoxyapatite coating enhances fixation of porous coated implants." Acta Orthopaedics research 61: 299-306.

61. Stea S., Bordini B., Sudanese A., Toni A. (2002). Registration of hip protheses at the Rizzoli Institute. 11 years experience. Othop. Scand. Suppl. 73 (305), 40-4.

62. Testi D., Zannoni C. et al. (2001). "Border Tracing algorithm implementation for the femoral geometry reconstruction." Computer Methods and Programs in Biomedicine 65: 175-182.

63. Toni A., Stea S., Bordini B., Traina F. (2002). Lost follow-up in a hip prothesis register. Experience of R.I.P.O. Othop. Scand. Suppl. 73 (305), 49-53.

64. Viceconti M., Muccini R. et al. (2000). "Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration." J Biomech 33(12): 1611-8.

(8)

65. Viceconti M., Monti L. et al. (2001). "Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems." Clin Biomech (Bristol, Avon) 16(9): 765-75.

66. Viceconti M., Cristofolini L., Baleani M., Toni A (2001). Pre-clinical validation of a new partially cemented femoral prothesis by synergetic use of numerical and experimental methods. Journal of Biomechanics 34, 723-731.

67. Wirtz D.C., Schiffers N. et al. (2000). "Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur."

Journal of Biomechanics 33(10): 1325-30.

68. Zienkiewicz O.C. and Taylor R.L. (2000). "The Finite Element Method".Volume I.The Basis 5 edition.

Riferimenti

Documenti correlati

[r]

Hepatic, splenic, and bone densities have been assessed placing nine ROIs (regions of interest) in the left lateral, right lateral, and quadrate liver lobes, three splenic ROIs,

- il compito e' stato rinormalizzato a 36, tenuto conto del notevole numero di domande rispetto al

[r]

[r]

risposta non e' stata data, oppure e' stata ottenuta con un procedimento completamente errato, oppure non e' stato trovato il procedimento stesso sui fogli consegnati. - quando tra

Se compare "." significa che la risposta non e' stata data, oppure e' stata ottenuta con un procedimento. completamente errato, oppure non e' stato trovato il procedimento

- :l (A.T.R.) Alluvioni sciolte di rocce palcozoichc delle sponde occidcutu li della rossa tcuonica, sopra banchi sino a 40150 metri di spessore di argille plastiche bianche o grigie