THERMO-MECHANICAL STRESSES ON THE BEAM WINDOW

V. Bellucci, S. Buono, G. Fotia, L. Maciocco, V. Moreau, M. Mulas, G. Siddi, L. Sorrentino CRS4 Research Centre ≠ Via N. Sauro, 10 ≠ Cagliari, Italy

Abstract

The Centre for Advanced Studies, Research and Development in Sardinia (CRS4) is participating to an Italian R&D program, together with Ansaldo, ENEA and INFN, devoted to the design of a 80 MW prototype of the Energy Amplifier proposed by C. Rubbia. The use of advanced numerical tools has been of practical support in the design of critical elements of the machine such as the fuel element and the beam target. The aim of this work is to study the sensitivity of beam window stresses to the beam distribution, size and interruption. In order to compute thermal stresses, the heat deposition in the window and in the coolant generated by the interaction with the proton beam is calculated and used as input data for the fluid dynamic simulation of the natural convection flow of the target coolant.

(2)

Introduction

The Energy Amplifier (EA) [1,2] is a nuclear system in which a beam target, driven by a proton accelerator, supplies an external source of neutrons to the subcritical core. The beam target represents one of the main technological problems related not only to the design of the EA, but to all High Power Spallation Sources currently under study or in construction world-wide [3,4].

Neutrons come from the interaction of a high power proton beam with the material contained in the target. Such interaction, called spallation, has the undesirable effects of producing a large quantity of heat (typically some MW concentrated in a small volume) and inducing an intense radiation damage in the structural materials. Liquid metals are currently considered the best choice in terms of target materials since they satisfy the important criteria of being the spallation medium and the cooling fluid at the same time and since their structural and thermal properties are not degraded by the radiation damage induced by proton interactions. Nevertheless, the corrosion of structural materials in a liquid metal environment is an important problem. Given the fact that the primary cooling loop of the EA is made of lead-bismuth eutectic (LBE), we consider the same coolant for the beam target. The LBE flow is driven by natural convection whose efficiency depends on the target height (which is related to the dimensions of the EA) and on the fluid dynamic design of the coolant circuit.

In the EA prototype target a window separates the internal part of the beam pipe from the coolant. Configurations using a beam window have additional problems of beam window cooling (in the window the highest temperatures and stresses are reached) and radiation damage induced in the window material. This damage is of a slight different nature from that induced in the other structures, since the window is exposed not only to back-scattered high-energy neutrons, but also to the high-energy proton flux. While steels for low power applications keep a sufficient structural resistance and are suitable candidates for the EA prototype [3-5], refractory alloys or more advanced materials are mandatory for high power applications [6,7].

The EA prototype target

The EA prototype target [5] is an axial symmetric device consisting of a ≥beam p i p e ≤ enclosed in a coaxial ≥container≤ (see Fig. 1). The beam pipe is made of martensitic HT-9 steel and is a vertical cylinder of 10 cm radius, 635 cm height and 3 mm thickness closed at the bottom by an HT-9 ≥window≤. The window has a hemispherical external surface and an ellipsoidal internal surface so that the thickness varies from a minimum of 1.5 mm in the beam pipe axis to a maximum of 3 mm in the junction with the cylindrical part of the beam pipe. The window is so tapered in order to reduce the beam heating in the beam pipe axis. The container is a vertical cylinder of 27 cm radius and 724 cm height with a hemispherical bottom. The region between the beam pipe and the container is filled with LBE and ≥vacuum≤ is made inside the beam pipe.

Having neglected the heat flux through the beam pipe and the container, the heat produced in the window and in the coolant is removed by a natural convection flow. This flow is guided b y the ≥flow guide≤, that is a 17 cm internal radius cylinder laying between the beam pipe and the container. The flow guide separates the internal hot flow rising from the spallation region from

(3)

the external cooled flow downcoming from the heat exchanger positioned on the top of the downcoming duct. In the spallation region the flow guide assumes a funnel shape which accelerates the flow and enhances the cooling of the window. The flow guide is made of two HT-9 layers 1 mm thick separated by a 1 mm layer of insulating material (Zirconium oxide). The heat exchanger is located at 25 cm from the container top, is 45 cm height and its outlet temperature is set to 180 C.

CONTAINER EXCHANGER

HEAT

VACUUM

SPALLATION REGION

WINDOW

FLOW GUIDE BEAM PIPE

Figure 1 ≠ Description of the EA prototype target.

Neutronic analysis

The proton beam is injected through the top of the beam pipe and interacts with the window, the coolant and the flow guide. The proton energy is 600 MeV and the beam size is assumed to be as a circular spot of radius

r

0 = 7.5 cm (the window radius allows a correct defocusing of the beam spot in order to prevent localised high power densities in the target materials). The beam current density is given by the three-dimensional parabolic profile

J I r

r

=  − r





2

0

1

0 2

2

0

π

2 (1) where the beam current

I

0 ranges from about 2 to 6 mA. In the following we assume the maximum beam current of 6 mA corresponding to a beam power of 3.6 MW.

The FLUKA Monte-Carlo code [8,9] is employed to calculate the heat source distribution, taking into account not only the electromagnetic interactions, but all kind of nuclear reactions induced by both protons and secondary generated particles. A 40∞70 orthogonal grid is used for the FLUKA simulation. The heat generated inside the funnel is calculated by applying the distribution for the coolant multiplied by the ratio between the flow guide density and the coolant density. According to the FLUKA computation, inside the window the proton beam deposits in form of heat about 22 kW (i.e. 0.6% of the beam power). The heat production in the coolant and in the flow guide is 72% and 1% of the beam power respectively, the rest of the beam energy

(4)

being contained in the particles escaping the system or in the binding energy of the target nucleus. Fig. 2 illustrates the contours of the beam power released in the LBE.

0.5 0.5

0.5 0.5

1

10 100

100

0.5 0.51

0.5 0.5

-20 -15 -10 -5 0 5 10 15 20

-10 0 10 20 30 40 50 60

Distance from the beam axis (cm)

Distance from the beam window (cm)

Power in W / cm^3 / mA

Figure 2 ≠ Neutronic calculation of the power generated in a thick LBE target by the proton beam.

Fluid dynamic analysis

The turbulent natural convection flow of the coolant and the thermal field in solids are simulated using the STAR-CD fluid dynamic code [10] where the heat source distribution calculated by the FLUKA code is used as input data. The vacuum inside the beam pipe is simulated by means of air at very low pressure. The heat exchanger is modelled as a thermal sink uniformly distributed. The numerical model employs a third order scheme for the spatial discretisation of the convective terms. The Chen k-ε model with a two-layer algorithm in the near wall region accounts for turbulence effects. The radiative heat flux through the beam pipe and the pressure losses in the heat exchanger are neglected. The container walls are assumed as adiabatic.

The IDEAS CAD and mesh generator [11] is employed to create a mixed structured/unstructured mesh. The fluid regions near the walls are meshed with structured grids, easier to handle and more suitable for the application of the turbulent near-wall algorithms.

Structured meshing is also used for the discretisation of the solids. The total number of cells is about 14000 and the discretisation is very accurate in the funnel zone, especially next to the window stagnation point.

Fig. 3 shows the computed velocity and temperature fields in the funnel region. The recirculation zone in the downcoming duct increases the temperature and reduces the natural convection pumping. However, the target height and the flow acceleration due to the convergent funnel shape generate the coolant velocity necessary for cooling the beam window to a maximum temperature of 427 C.

(5)

Figure 3 ≠ Velocity and temperature fields in the funnel region.

Structural analysis

The MSC/NASTRAN structural code [12] is employed to calculate the stresses induced in the window/pipe system by using a linear (elastic) model applied to the same window/pipe grid used for the fluid dynamic simulation. The temperature field is assigned to the elements of the model and the coolant hydrostatic pressure distribution is applied onto the external surface.

The maximum Von Mises stress is 109 MPa, the maximum ≥meridional≤ (i.e. tangent to the window profile) stress is 102 MPa and the maximum ≥hoop≤ (i.e. perpendicular to the plane of study) stress is 101 MPa. The maximum window temperature is 427 C which corresponds to an Ultimate Tensile Strength (UTS) of 610 MPa (this value is conservative due to the UTS decrease when the temperature increases). The values of temperature and stress are within the HT-9 application range described in [13].

Beam distribution effects

The window stresses sensitivity to the beam distribution is studied by considering gaussian and uniform distributions having the same proton energy and beam current of the parabolic distribution given by Eq. (1) (see Figs. 4 and 5). The corresponding heat flux to be removed from the window decreases in the beam axis according to the smaller window thickness.

Fig. 6 shows the temperature distributions on the internal (window/vacuum) and external (window/coolant) surfaces as a function of the angle α between the target axis and the window (or pipe) circumference orthogonal to the axis (the proton beam crosses the window up to an angle of 48.6 ).

L L K K

L JK GHHI

D

LL L K

L HI JK

E D

EFG

HI F

E

BC E

CDCD E

F H

E D

E

DE

B FG FH F H II

I HI

I

FG HI

I FGHGH

G F

I F

C

F H

H

M

HI H

GH G F F GH

FGHI FGHII

GH

M G B ECEF

L E

M B

L I J CE

G H GGH F

B H

L L L I

LLL

I K

K JJ JK

K I

M

M MM MM FG

M L

L JKL M

H H

HI J G F

G

F G I E

J K

K E

L E

GHI H

K J K

J M K L

L

MM M DE D

TEMPERATURE ABSOLUTE KELVIN LOCAL MX= 600.9 LOCAL MN= 470.5

A 595.0 B 585.0 C 575.0 D 565.0 E 555.0 F 545.0 G 535.0 H 525.0 I 515.0 J 505.0 K 495.0 L 485.0 M 475.0

(6)

Figures 4 and 5 ≠ Assigned proton beam particle distributions and corresponding heat flux calculated by FLUKA in the window for different beam distributions.

0 10 20 30 40 50 60 α (deg)

external internal

UNIFORM

0 10 20 30 40 50 60 GAUSSIAN

internal

external

α (deg) 0 10 20 30 40 50 60

250 300 350 400 450 500 550

α (deg) Temperature (o C)

external internal PARABOLIC

Figure 6 ≠ Temperature distributions on the internal and external window surfaces.

The gaussian distribution leads to window temperatures out of the HT-9 application range.

With respect to the parabolic distribution, the gaussian and uniform distributions have greater temperature gradients and therefore greater stresses close to the beam axis and edge respectively, as illustrated in Figs. 7 and 8 where the meridional and hoop stress components in the internal and external window fibres are reported. The maximum Von Mises stresses are 189 and 149 MPa for the gaussian and uniform distribution respectively. The gaussian distribution produces stresses out of the HT-9 application range. The thinner part of the window, which is also the most loaded in the non-uniform distribution case, undergoes strong bending moments (depending basically o n the temperature gradient along the thickness).

0 0.05 0.1 0.15 0.2 0.25 0.3

0 1 2 3 4 5 6 7 8 9 10

1/N dn/dx

Distance from the beam axis (cm) Gaussian distribution (FWHM = 7 cm)

r(max) = 7.5 cm Parabolic distribution

Uniform distribution

0 10 20 30 40 50 60

0 1 2 3 4 5 6 7 8 9 10

Heat flux (W/cm^2/mA)

Distance from the beam axis (cm)

Gaussian Distribution Uniform Distribution Parabolic Distribution

(7)

Figure 7 ≠ Meridional stress components in the internal and external window fibres.

0 50 100 150

α (deg) UNIFORM

external

internal

0 50 100 150

α (deg) external

internal GAUSSIAN

0 50 100 150

-180 -120 -60 0 60 120 180

α (deg) external

internal

Hoop stresses (MPa)

PARABOLIC

Figure 8 ≠ Hoop stress components in the internal and external window fibres.

Beam size effects

One of the most dangerous accidents expected in the beam window is a reduction of the beam size. In order to analyse such effect we reduced the beam spot radius down to a dimension of 3 cm. Fig. 9 shows that the maximum temperatures reached on the external and internal window surfaces in the beam axis are immediately out of the utilisation range of a HT-9 steel.

The corresponding maximum meridional, hoop and Von Mises stresses normalised with respect to the UTS are shown in Fig. 10 and illustrate that also stresses are immediately out of the application range when reducing the spot size.

0 50 100 150

α (deg) UNIFORM

external

internal

0 50 100 150

α (deg) external

internal GAUSSIAN

0 50 100 150

-180 -120 -60 0 60 120 180

α (deg) external

internal

Meridional stresses (MPa)

PARABOLIC

(8)

Figure 9 ≠ Temperature on the window surfaces in the beam axis vs beam radius.

Figure 10 ≠ Normalised maximum meridional, hoop and Von Mises stresses vs beam radius.

Beam interruption effects

When the beam is interrupted, window temperatures decrease to the heat exchanger exit temperature. The beam interruption transient is calculated by a structural analysis decoupled b y the fluid dynamic transient. The MSC/NASTRAN code is used where the coolant temperature is supposed to decrease from 360 C (see Fig. 6) to 180 C in 0.15 s, according to the coolant velocity field near the window. The window/coolant heat flux is computed by using a heat transfer coefficient of 20000 Wm2K1 obtained by a forced convection fluid dynamic analysis of the window flow without the LBE heat source. Figs. 10 and 11 show the maximum temperature and Von Mises stress in the window during the transient.

2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 300

500 700 900 1100 1300 1500

Spot radius r0 (cm) Temperatures in the beam axis (o C)

internal

external

2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 0.0

0.2 0.4 0.6 0.8 1.0 1.2

Spot radius r0 (cm)

Stresses / UTS

max meridional max hoop max Von Mises

(9)

Figures 10 and 11 ≠ Maximum window temperature and Von Mises stress during the beam interruption transient.

Under the approximation done on the coolant temperature transient, each beam interruption longer than about 4.5 s produces a stress cycle whose maximum Von Mises stress is 175 MPa. By neglecting the creep damage, the fatigue life may be determined from a design curve based upon strain cycling fatigue data generated at the maximum temperature [14]. In [15] a design curve for medium-strength pressure vessel steels is given, leading to a number of cycles to failure equal to 1 05. However to predict thermal fatigue life with a higher degree of accuracy it is necessary to simulate the coupled thermal and fluid-dynamic transient and to acquire data about the thermal stress behaviour of the specific steel, the irradiation damage and the corrosion effects.

Conclusions

Extensive numerical calculations have been performed to study the thermo-fluid dynamics and the structural loads on the EA 80 MW prototype target. In the limits of the geometrical constraints of the system, a thermal hydraulic optimisation of the target allows the use of natural convection. The relatively low power beam of the machine (600 MeV of beam energy and 26 mA of beam current) allows the use of a martensitic steel in the beam window. This deeply alleviates the problems related to the construction, the assembly and the operation of the window under intense proton irradiation.

When changing the uniform beam distribution from parabolic to gaussian or uniform, window temperatures and thermal stresses increase and eventually go out of the steel application range. When reducing the beam size temperatures and stresses still increase but in this case are immediately out of the steel utilisation range.

A simplified study of the fatigue damage induced by cyclic beam interruptions (longer than about 4.5 s) leads to predict the allowable number of interruptions to failure. In this analysis the more critical points remain the need of data on steel thermal cycle fatigue, irradiation damage and corrosion.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5

150 180 210 240 270 300 330 360 390 420 450

Max. temperature in the window (oC)

Time (s)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5

0 30 60 90 120 150 180

Time (s)

Max. Von Mises stress in the window (MPa)

(10)

References

[1] C. Rubbia et al., ≥Conceptual Design of a Fast Neutron Operated High Power Energy Amplifier≤, CERN Report, CERN/AT/95-44 (ET), Geneva, September 29, 1995.

[2] C. Rubbia, ≥A High Gain Energy Amplifier Operated with Fast Neutrons≤, AIP Conference Proceedings 346, International Conference on Accelerator-Driven Transmutation Technologies and Applications, Las Vegas, July 1994.

[3] Proceedings of the Meetings ICANS-XIII and ESS-PM4, edited by G. Bauer and R. Bercher, PSI proceedings 95-02, November 1995.

[4] Proceedings of the ≥International Workshop on the Technology and Thermal Hydraulics of Heavy Liquid Metals≤, compiled by B.R. Appleton and G.S. Bauer, Schruns, Montafon Valley, Austria, March 25-28, 1996.

[5] L.Maciocco et al., ≥Design and Optimisation of a Liquid Metal Spallation Target for the Energy Amplifier Prototype≤, 2nd International Topical Meeting on Nuclear Applications of Accelerator Technology, Gatlinburg, TN, USA, September 20-23, 1998.

[6] S. Buono and C. Rubbia, ≥A comparison of different materials for the beam window of the Energy Amplifier≤, CERN/ET Internal Note 96-26, Geneva, August 27, 1996.

[7] S. Buono and C. Rubbia, ≥A Tungsten-Rhenium Alloy as a beam window material for the Energy Amplifier≤, CERN/ET Internal Note 96-24, Geneva, July 9, 1996.

[8] A. FassÚ et al., ≥FLUKA92≤, Workshop on Simulating Accelerator Radiation Environments, Santa Fe, USA, January 11-15, 1993.

[9] A. Ferrari and P.R. Sala, ≥Improvements to the Electromagnetic part of the FLUKA code≤, MC93 Int. Conf. on Monte-Carlo Simulation in High-Energy and Nuclear Physics, Tallahassee, February 22-26, 1993.

[10] STAR-CD Version 3.05 User Guide, Computational Dynamics Limited, 1998.

[11] IDEAS Master Series 5, Structural Dynamics Research Corporation.

[12] MSC/NASTRAN Version 70.5, MacNeal-Schwendler Corporation.

[13] Y. Dai, ≥Martensitic/ferritic Steels as Container Materials for Liquid Mercury Target of ESS'', International Workshop on the Technology and Thermal Hydraulics of Heavy Liquid Metals, Schruns, Austria, March 1996.

[14] Thermal Stresses II, edited by R. Hetnarski, Elsevier Science Publishers, Amsterdam, The Netherlands, 1987.

[15] C. Osgood, Fatigue Design, John Wiley & Sons, New York, USA, 1970.

Riferimenti

Documenti correlati

della disciplina sulla prova irripetibile agli orientamenti di Strasburgo in merito ad essa. La Costituzione, infatti, nel momento in cui consacra il contraddittorio come

In conclusione, si può affermare che l’analisi empirica ha dimostrato come il reddito, la share di permessi di soggiorno di lungo periodo, il tasso d’inflazione in Italia e il pil

The specificity of the effects of the tested drugs against GSC subpopulation was further demonstrated showing that 24 h treatment of GBM1 and GBM2 cultures with metformin,

Il problema della legittimità del potere accompagnò così sin dagli esor- di i protagonisti della Rivoluzione francese; uno dei primi a rendersi conto che la distruzione della

A detailed MSC/NASTRAN v70.5 linear elastic finite element model of the window/pipe system has been used to predict for each discrete time the stress field induced by the

BHE bundle ext.. Figure 6: case d) Velocity field and velocity magnitude distribution in the spallation zone of the target.. Figure 8: case d) Beam window temperature profile in

CRS4-Technical report 01/xx DRAFT channel, as shown on the right, solve this problem and transport the hottest point in the bulk of the channel... Figure 14 Effect of the restriction

The dump vessel and transfer line are separated by a 600 mm diameter window, which must withstand both the static pressure load and thermal shock from the passage of the LHC beam.. In