ARVO Annual Meeting Abstract  |   June 2013

The effect of the Hydrus trabecular shunt on

endothelial cell count: a double blind prospective

randomized clinical study

Antonio Fea; Giulia Consolandi; Giulia Pignata; Paola Maria Loredana Cannizzo; Marco Dal Vecchio; Francesco Gallozzi; Carlo Lavia; Teresa Rolle; Federico Grignolo

 Author Affiliations & Notes

Investigative Ophthalmology & Visual Science June 2013, Vol.54, 4788. doi:

Abstract

Purpose: One of the major complications of glaucoma tube surgery is the endothelial cell loss. Recently trabecular micro-shunts have been proved effective in reducing intraocular pressure in conjunction with cataract surgery, but there are no reports on their potential side effects on the endothelium.

Methods: In a double masked prospective randomized clinical study, endothelial cell count of patients undergoing cataract surgery (controls) or cataract and Hydrus stent (Ivantis) implant (cases) was performed at baseline and 3 months after surgery. Patients with an endothelial cell density lower than 1500 or with endothelial guttae were excluded. Endothelial cell evaluation was performed with a Konan Cellchek XL. The percentual change of the preoperative and postopoerative CD, SD, CV and SA was compared between the two groups using umpaired Student t-test. All surgery was performed by the same surgeon (AF)

Results: A total of 24 patients were included in the study using a 2 :1 randomization criterion (8 controls: 16 cases). Two patients were excluded because of cornea guttata. Cases and controls had comparable pre-operative endothelial parameters (CD: controls: 2373+/-114 cases: 2495+/-80; SD: controls: 145+/-16 cases: 163+/-11; CV: controls: 33.4+/-2.7 cases: 39+/-1.9; SA: controls: 53+/-3.3 cases:56+/-2.4). The percentual decrease in cell density between groups (cases: 16,6&+/- 17.2 controls: 12%+/-12.1)after surgery was not significantly different (p=0.5). Conclusions: The Percentual CD reduction in both groups is comparable to the data reported in the literature. The implant of the Hydrus device in conjunction of cataract surgery does not seem to significantly affect the

endothelial cell count in the short term. Long term studies are warranted.

Keywords: 481 cornea: endothelium  

© 2013, The Association for Research in Vision and Ophthalmology, Inc., all rights reserved. Permission to republish any abstract or part of an abstract in any form must be obtained in writing from the ARVO Office prior to publication.

The effect of the Hydrus trabecular shunt on endothelial cell count: a do... http://iovs.arvojournals.org/article.aspx?articleid=2149684&resultClick=1

Riferimenti

Documenti correlati

processo di controllo: gli obbiettivi di budget devono essere definiti coerentemente con i piani d’azione individuati in sede di programmazione e con le risorse

The choice of this benchmark model is motivated by the key role it plays in the most recent and sophisticated dynamic spatial general equilibrium model, such as the

Seen from a design point of view, the images and thoughts immediately summon up the studies and thinking of Donald Norman (1990), who examines how much bad designing of a minute

Il programmatore del computer può così assurgere alla dimensione di una vera e propria ipostasi metafisica nell’ambito di una nuova religiosità: Il programmatore computer copyright

Direct DM searches give strong constraints on the mediator interactions, but there are still certain windows of mediator mass and couplings that lead to a correct thermal

Despite its limited scale, the experience of the CLAIRE COVID-19 initiative has not only made concrete progress on COVID-19 problems, but offered insights on the potential and

Conduction recovery following catheter ablation in patients with recurrent atrial fibrillation and heart failure..

All HER2-positive carcinomas except one grouped within the cluster enriched for HER2 amplicon–related genes together with 2 double-equivocal carcinomas classified as luminal B