• Non ci sono risultati.

fulltext

N/A
N/A
Protected

Academic year: 2021

Condividi "fulltext"

Copied!
3
0
0

Testo completo

(1)

DOI 10.1393/ncc/i2011-10795-y Colloquia: IFAE 2010

IL NUOVO CIMENTO Vol. 33 C, N. 6 Novembre-Dicembre 2010

An innovative tracker for precision measurements at KLOE-2

G. Morellofor the KLOE-2 Collaboration

Universit`a della Calabria and INFN, Gruppo collegato di Cosenza - Cosenza, Italy

(ricevuto l’ 8 Ottobre 2010; pubblicato online l’8 Febbraio 2011)

Summary. — A new Inner Tracker is going to be realized for the KLOE-2

ex-periment at DAΦNE. The tracker is based on GEM technology in order to improve vertices resolution near the interaction point, thanks to the low material budget and consequently a low effect of multiple scattering. Here there follows a description of the detector and some measurements performed.

PACS 29.40.Cs – Gas-filled counters: ionization chambers, proportional and avalanche counters.

PACS 29.40.Gx – Tracking and position-sensitive detectors.

1. – The KLOE experiment

The KLOE experiment [1] collected an integrated luminosityLdt ∼ 2.5 fb−1 at the

Frascati φ-factory DAΦNE, an e+e collider, at a center-of-mass energy of 1020 MeV.

The experiment achieved several precision results both in kaon and hadron physics: the

measurements of all branching ratios of KS, KL and K±, the study of scalar and

pseu-doscalar mesons and e+e− → π+π− cross section, giving the low-energy hadronic

con-tribution to the muon anomaly. A detailed description of the experiment can be found in [1].

2. – KLOE-2

At KLOE-2 the interest will be focused on physics coming from the IR: KS decays,

KS-KLinterference, η, ηand K± decays, multi-leptons events. Such a research requires

an additional tracker detector (Inner Tracker) [2, 3] between the beam pipe and the inner wall of the central tracking chamber. It will: 1) reduce the track extrapolation length and improve the decay vertex reconstruction capability; 2) increase the geometrical acceptance for low momentum tracks; 3) improve track momentum resolution (fig. 1).

The Inner Tracker must satisfy the following requests: σrφ ∼ 200 μm and σZ

500 μm, < 2%X0 material budget, 5 kHz/cm2 rate capability.

c

(2)

222 G. MORELLO for the KLOE-2 COLLABORATION

Fig. 1. – Simulated resolution σpt/pt on the transverse momentum measurement as a function

of pT for KS→ π+π− (left) and η→ π+π−e+e−(right) with DC only (circles) and with the

addition of the IT information (triangles).

3. – The Inner Tracker

The proposed solution is based on GEM technology: four layers of cylindrical triple-GEM with radii between 13 cm and 23 cm, 70 cm active length, XV strips readout with

a stereo angle of 40 and a total radiation length of 1.5%X0. A full-scale CGEM

pro-totype was built, with 15 cm radius and 35 cm active length. The construction process is described in [2]. The anode was patterned with 650 μm pitch longitudinal strips. The chamber was tested with X-rays and, once equipped with 16-channels prototype GAS-TONE ASIC chip, tested at CERN with 10 GeV pion beam. The detector was flushed

with Ar : CO270 : 30 gas mixture and operated with the fields E = 1.5/2.5/2.5/4 kV/cm

and with the GEM voltages 390/380/370 V, corresponding to a gas gain of 2× 104. The

tracks reconstructed by two external tracker stations were compared to those recon-structed by the prototype [4]. The reconstruction efficiency is about 99.6% while the

CGEM spatial resolution is ∼ 200 μm, in good agreement with what expected from a

digital readout of the strips. Since the IT will be equipped with XV patterned strips and it will operate in magnetic field, a dedicated test to address these issues was performed

at CERN with 150 GeV pion beam line. Five 10× 10 cm2 planar triple-GEM detectors

were assembled with 650 μm pitch strips. Four of them were equipped with standard XY readout [5], while the fifth with the XV geometry. All the chambers were placed in mag-netic field adjustable up to 1.5 T. The magmag-netic field affects the drift motion of electrons making a displacement between the track and the area where signals are induced and in-creasing the electron spread over the readout, as shown by GARFIELD simulations (fig. 2

(left)). The gas mixture was Ar : CO2 70 : 30, with the fields 1.5/3/3/5 kV/cm and the

voltages 390/380/370 V applied on GEM foils. In order to measure the displacement dx, the four XY chambers were likewise oriented, while the XV chamber was reversed. The distance between the reconstructed track and the point of the XV chamber is twice the displacement of the electrons in a chamber. The dx was measured for different magnetic fields (fig. 2 (right)). The spatial resolution was measured as a function of the gain of the GEM and of the magnetic field (fig. 3 (right)). As shown in fig. 3 (left), the efficiency drops as the magnetic field increases. This effect can be reduced working at higher gain which consequently involves a worse spatial resolution.

(3)

AN INNOVATIVE TRACKER FOR PRECISION MEASUREMENTS AT KLOE-2 223 Magnetic field (T) 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Displacement (mm) -0.2 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8

X displacement as function of magnetic field Experimental values Simulated value

Fig. 2. – GARFIELD simulation (left) and measurements of electron displacement as a function of the magnetic field (right).

Voltage (V) 1060 1080 1100 1120 1140 1160 Efficiency % 50 60 70 80 90 100 Efficiency vs Voltage (th=3.5 fC) B = 0T B = 0.3T B = 0.5T B = 0.75T B = 1T B = 1.35T Magnetic Field (T) 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Resolution (mm) 0.18 0.2 0.22 0.24 0.26 0.28 0.3 0.32 0.34 0.36 0.38

Resolution X vs magnetic field

Fig. 3. – Efficiency as a function of voltage and magnetic field (left) and x resolution as a function of the magnetic field (right).

4. – Conclusions

The beam tests performed on the KLOE-2 Inner Tracker prototype have demonstrated the feasibility of this detector. The readout geometry was validated and the test in magnetic field was successful in terms of achieved spatial resolution. The R&D phase is concluded and the construction of the Inner Tracker has started.

REFERENCES

[1] Bossi F. et al. and KLOE Collaboration, Riv. Nuovo Cimento, 31 (2008) 531. [2] KLOE-2 Collaboration, Technical Design Report of the Inner Tracker for the KLOE-2

experiment, ArXiv 1002.2572v1 and LNF-10/3(P) INFN-LNF Frascati (2010).

[3] Di Domenico A. and KLOE-2 Collaboration, J. Phys.: Conf. Ser., 171 (2009) 012008. [4] Domenici D. et al., in 2009 IEEE Nuclear Science Symposium. Conference Records. [5] Balla A. et al., Nucl. Instrum. Methods A, 604 (2009) 23.

Riferimenti

Documenti correlati

It showed the presence of a duplication of the region 11q25, including the Neurotrimin (NTM) gene, inherited from the asymptomatic father, a de novo deletion of the

TR distribution among different regions: exon, intergenic region, large single-copy region (LSC), small single-copy region (SSC), and inverted repeat b (IRb); Figure S6:

application, here we deduce a Brill-Noether existence theorem for irreducible curves obtained from a Brill-Noether curve by identifying a pair of points to an ordinary node..

University of Zagreb - International Research Center for Late Antiquity and the Middle Ages, Motovun, Croatia University of Zagreb - Faculty of Humanities and Social Sciences,

Francesca Assennato, Valter Bellucci, Pietro Massimiliano Bianco, Marco Di Leginio, Carla Iadanza, Ines Marinosci, Michele Munafò, Stefano Pranzo, Astrid Raudner, Andrea

Il glicocalice rappresenta lo strato scivoloso e non adesivo che protegge la superficie sierosa da abrasioni, infezioni e diffusione di tumori (S.. organi all’interno

This is necessary because the correlations between the K S 0 decay time and the kinematics of the D ∗ meson and the soft pion 2 introduce a difference in production and

Per la valutazione della contaminazione microbiologica, sono stati disposti campionamenti dell’aria e delle superfici delle sale operatorie. Con la doppia linea si separano