DOI 10.1393/ncc/i2019-19206-7 Colloquia: IFAE 2018

IL NUOVO CIMENTO 42 C (2019) 206

Micro-TPC reconstruction performance for planar GEM

detector with high-rate beam

I. Balossino(1)(2) on behalf of CGEM-IT Group

(1) INFN, Sezione di Ferrara - Ferrara, Italy

(2) Dipartimento di Fisica, Universit`a di Ferrara - Ferrara, Italy received 31 January 2019

Summary. — A new reconstruction method for the Micro Pattern Gas Detectors (MPGD) has been implemented, called Micro-TPC, and implemented for Gas Elec-tron Multiplier (GEM) detectors. The possible dependence of the drift velocity on the presence of residual charge in high-rate conditions motivated the test performed with planar GEM at MAMI Facility in Mainz. In this work the Micro-TPC tech-nique, the setup and the results of the test beam that allowed to find the optimal working conditions will be presented.

1. – Introduction

Gas Electron Multiplier : GEM detectors were invented by Sauli [1] in 1997. GEMs

are built as thin Kapton foil covered by copper and pierced with small bi-conical holes (50 μm). The electron avalanche multiplication happens inside the holes, where a high field is provided by applying a voltage to the copper layers. In triple-GEM detectors, three GEM foils are placed between an anode and a cathode, as shown in fig. 1.

Micro-Time Projection Chamber : The goal is to calculate the position of the primary

ionization points inside the drift gap minimizing the error. This is performed in the fol-lowing steps (fig. 2) once a cluster is found: 1) extrapolation of the position by measuring the time of arrival of the signal on the anode assuming constant drift velocity; 2) linear fit of all the found positions; 3) position measurement from the fit that corresponds to half gap.

Test beam at MAMI : A check of the Micro-TPC performance in a challenging

environ-ment such as the MAinz MIcrotron Facility was performed thanks to the high-rate beam. Here four triple-GEM planar chambers (10× 10 cm2) have been tested with two different

gas mixtures, Ar:iC4H10 (90:10) and Ar:CO2(70:30). The chambers could rotate to test

the Micro-TPC at different incident angles.

(2)

2 I. BALOSSINO on behalf of CGEM-IT GROUP

Fig. 1. – Avalanche scheme.

Fig. 2. – Micro-TPC reconstruction method.

2. – Results

A description of the results on the parameters that may affect the performance of Micro-TPC in high-rate environment is presented.

Gain: fig. 3 shows that the gain behaviour is compatible with the one of ref. [1]. The

gain is stable up to more than 106Hz/cm2, then it increases up to 107Hz/cm2 to drop

right afterwards. The possible explanation to this behaviour is correlated to the positive charge accumulation that modifies the electric field and increases the transparency of the GEMs.

Time resolution: It takes into account both the time resolution of the detector itself

and the one of the electronics. In both gas mixtures fig. 4 shows the parameter stability with the rate up to 107Hz/cm2.

Drift velocity: The drift velocity has been calcualted by the time difference between

the first and the last hit strips. The stability of this parameter up to 107Hz/cm2validate

the method with both gas mixtures, as shown in fig. 5.

(3)

MICRO-TPC RECONSTRUCTION PERFORMANCE FOR PLANAR GEM DETECTOR ETC. 3

Fig. 4. – Time resolution vs. rate [2].

Fig. 5. – Drift velocity vs. rate [2].

3. – Conclusions

The use of the Micro-TPC reconstruction method has been validated at high rate up to 107Hz/cm2.

REFERENCES

[1] Sauli F., Nucl. Instrum. Methods A, 805 (2016) 2.

[2] Lavezzi L. et al., Performance of the Micro-TPC Reconstruction for GEM Detectors at High Rate, arXiv:1803.07266 [physics.ins-det].

Riferimenti

Documenti correlati

Here, to make up for the relative sparseness of weather and hydrological data, or malfunctioning at the highest altitudes, we complemented ground data using series of remote sensing

In questo interessante scenario, in caso di densità di traco fortemente asimmetrica, la soluzione di equilibrio prevede che un operatore installi la propria RSU nel sito che

CB-PCPs are imidazolium functionalized porous polymers, obtained via facile click-synthesis, and bearing all the common anions used in the field of PILs for carbon

This Handbook has been created with a view to accompany a course on Migration Studies from a multidisciplinary perspective. With this course we want to address the topic of

Kropivnickij, Jan Satunovskj (come anche, in un periodo successivo, il “discepolo” del primo G Sapgir) e molti altri hanno attinto i tratti distintivi della propria produzione

Negli ultimi anni, sono stati anche identificati diversi canali al potassio presenti nella membrana mitocondriale interna, i quali si ritengono coinvolti nei

In the end, it is worth noticing that by applying only 270 patches, 244 in the first set and 26 in second, the 12,8% of the overall system vulnerabilities, the Italian Blue Team

II anno di corso / I course year (anno accademico / academic year 2016-2017) DENOMINAZI ONE DEL CORSO / NAME OF THE COURSE DURATA / DURATIO N (in ore / in hours) SEDE / LOCATIO