• Non ci sono risultati.

[1] Jianming Jin, “Electromagnetic Analysis and Design in Magnetic Resonance Imaging”, CRC Press, 1999

N/A
N/A
Protected

Academic year: 2021

Condividi "[1] Jianming Jin, “Electromagnetic Analysis and Design in Magnetic Resonance Imaging”, CRC Press, 1999 "

Copied!
3
0
0

Testo completo

(1)

159

Bibliografia

[1] Jianming Jin, “Electromagnetic Analysis and Design in Magnetic Resonance Imaging”, CRC Press, 1999

[2] Notes on MRI , Part II-III www.bme.umich.edu

(/∼dnoll/BME483/imag1.pdf- imag2.pdf)

[3] Khandpur, “Handbook of biomedical instrumentation”, MacGraw-Hill, 1991

[4] C-N Chen and D I Hoult, “Biomedical magnetic resonance technology”, Adam Hilger, 1989

[5] M. Kasal, J. Halamek, V. Husek, M. Villa, U. Ruffina, P. Cofrancesco, “Signal processing in tranceivers for nuclear magnetic resonance and imaging”, Rev. Sci. Instrum., Vol 65, No 6, giugno 1994

[6] M. Villa, F. Tiang, P. Cofrancesco, J. Halàmek, M. Kasal,

“High-resolution digital quadrature detection”, Rev. Sci. Instrum., Vol 67, No 6, giugno 1996

[7] J.P Hornak, “The Basics of MRI”, www.cis.rit.edu/htbooks/mri

[8] Walt Kester, “Undersampling application” -section 5-, Analog Devices, application note

[9] Walt Kester, “High speed sampling and high speed ADCs”, Analog Devices, application note

[10] Brad Brannon, “Aperture uncertainty and ADC system performance” , Analog Devices, application note 501

[11] Brad Brannon, “Basics of designing a digital radio receiver (radio 101)”, Analog Devices, application note

[12] AD9243 Datasheet, Analog Devices

[13] AD6620 Datasheet, Analog Devices

(2)

160 [14] “Designing filters with AD6620”, Analog Devices

[15] James M. Bryant, “The effect of clock noise on sampled data systems”, Analog Devices

[16] SCO-020 Datasheet, Sunny Electronics

[17] MC88915 Datasheet, Motorola

[18] AD6620 Evaluation Board Manual, Analog Devices

[19] “Sampled Data System” –section 2-, Analog Devices, application note

[20] G.Giovannetti, L.Landini, M.F.Santarelli, V. Positano

“ A fast and accurate simulator for the design of birdcage coil in MRI ”, Magn.Reson.Mat.in Phys. Biolog. and Med.

vol.15/1-3 pag.36-44 (2002)

[21] L.Darrasse, G.Kassab, “Quick measurement of NMR-Coil sensitivity with a dual loop probe”, Rev.Sci.Instrum.1993, 64, pag.1841-1844

[22] “Oversampling techniques using the TMS320C24X family”, Texas Instruments Europe

[23] AD9100 Datasheet, Analog Devices

[24] Mark Sauerwald, “Effects of aperture time and jitter in a sampled data system” National semiconductor, application note AD-03

[25] V. Christofilas,A.A.Alexandridis, P. Kostarakis, K. Daugakis,

2Analog to digital converter: a key concept in the implementation of a

3G software defined radio receiver”

(3)

161 [26] P.Perez, A. Santos, J.J. Vaquero, “Potential use of the undersampling technique in the acquisition of nuclear magnetic resonance signal” MAGMA 13(2001) 109-117

[27] AD9245 Datasheet, Analog Devices

Riferimenti

Documenti correlati

The basic concept of the SDR software radio is that the radio can be totally configured or defined by the software so that a common platform can be used across a number of areas and

“A three-dimensional progressive damage model for bolted joints in composite laminates subjected to tensile loading” Fatigue and Fracture of Engineering Materials and

Image formation by induced local interactions: examples employing nuclear magnetic resonance... Image formation by induced local interactions: examples

An object-oriented designed finite-difference time-domain simulator for electromagnetic analysis and design in MRI-applications to high field analyses.. On the Analysis of

We address the following topics: appropriate choice of imaging planes and routine sequences, why and how to perform contrast-enhanced studies, and the choice of sequences, depending

– immediately after the 90° pulse, a negative magnetic field gradient is applied; the spins start precessing at a position-dependant speed, dephas- ing in an “ordinate” manner with

[r]

“The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods”.. Howseman