UNIVERSITÀ DI PISA

.

.

Dipartimento di Ingegneria dell’Informazione

Corso di Laurea Magistrale in Ingegneria Biomedica

Tesi di Laurea Magistrale

Nuovi metodi diretti per la stima

dei parametri cinetici da immagini

PET dinamiche

New methods for direct estimation of kinetic

parameters from dynamic PET data

Relatori

Prof. Luigi Landini

Prof.ssa Maria Filomena Santarelli

Controrelatore

Candidato

Prof. Vincenzo Positano

Michele Scipioni

(2)
(3)

Sommario

Riuscire ad ottenere una stima diretta dei parametri cinetici dai dati prodotti da un esame dinamico di tomografia ad emissione di positroni (PET) rappresenta ad oggi un obiettivo ambizioso quanto ancora lontano dall’effettiva applicazione alla pratica clinica.

Attualmente, il protocollo standard per l’analisi cinetica quantitativa del processo di metabolizzazione del tracciante può essere descritto come un metodo indiretto, strutturato in due passaggi distinti: partendo dai dati di emissione si ricostruisce la sequenza di immagini dinamiche che, successivamente, viene analizzata mediante modelli compartimentali.

L’algoritmo che sarà oggetto di questo lavoro andrà invece a combinare in un’unica formula queste due operazioni: lavorare direttamente sui dati di proiezione consente di migliorare sia la qualità che la velocità della stima ottenuta.

Dopo aver fornito una descrizione teorica del modello utilizzato, ne è stata realizzata un’implementazione software per mezzo della quale si è andati quindi a valutare, tra-mite simulazioni Monte Carlo su un fantoccio di test omogeneo, le prestazioni dello stesso nella risoluzione di problemi di stima parametrica e ricostruzione di immagini dinamiche in diverse condizioni di rapporto segnale-rumore, al fine di verificare la ro-bustezza del metodo in condizioni operative non ideali. Successivamente sono state svolte simulazioni su fantocci realistici che riproducessero delle sezioni anatomiche di interesse (zona toracica e cerebrale) che hanno portato, infine, ad un primo test esplorativo su dati reali sperimentali.

(4)

Abstract (english version)

Being able to obtain a direct kinetic parameters estimate from dynamic positron emission tomography (PET) data today represents an ambitious goal as yet far from the actual application to clinical practice.

Currently, the standard protocol for quantitative kinetic analysis of tracer’s metabo-lization process can be described as an indirect method, structured in two separate steps: starting from the emission data, a sequence of dynamic images is first recon-structed and then analyzed by compartmental models.

The algorithm that will be the subject of this work aims to combine into a single formula these two operations: working directly on the projection data can improve both the quality and the speed of the resulting estimate.

After providing a theoretical description of the model used, we present a software implementation by which we could evaluate, via Monte Carlo simulations on an homogeneous test phantom, its performance in the resolution of task related to pa-rameter estimation and reconstruction of dynamic images in different conditions of signal to noise ratio, in order to verify the robustness of the method in non-ideal operating conditions. Subsequently simulations of realistic phantoms were carried out to reproduce the behaviour of some anatomical sections of interest (thoracic and cerebral). This led, ultimately, to a first exploratory test on real experimental data.

Riferimenti

Documenti correlati

Tale circostanza introduce ovviamente diversi problemi in quanto oltre a rendere più complesso il comportamento dinamico dell’edificio a causa della non regolarità geometrica,

Per i periodici, le dichiarazioni o le rettifiche sono pubblicate, non oltre il secondo numero successivo alla settimana in cui è pervenuta la richiesta, nella stessa pagina che

rappresentanza dell’ente, in qualità di coordinatrice della Commissione Affari Europei, la Presidente della Regione Umbria Donatella Tesei che ha sottolineato come il Governo

Le somme di Gauss sono lo strumento matematico che ` e alla base dell’algoritmo di primalit` a ideato da Adleman, Pomerance e Rumely nel 1980 e dunque in questo capitolo

Aldilà delle peculiarità applicative dei tre modelli, il vero distacco emer- ge a livello teorico ed epistemologico nel momento stesso in cui il ter- mine knowledge building

terminale rimane utilizzabile (il comando viene.. 4) abbiamo visto come si può utilizzare ds9 fuori da IRAF o attraverso IRAF (tv e poi disp).. Scaricate ora le due immagini

[18] Toci E., Applicazione di tecniche di Reverse Engineering per la ricostruzione di modelli CAD di prototipi fisici, Tesi di Laurea in Ingegneria Meccanica presso la Facoltà

Betti, “Sperimentazione di una tecnica di controllo della instabilità di combustione nei turbogas su un impianto sperimentale a pressione atmosferica”, ENEL Produzione, 2001..